6,994 research outputs found
Receipt from John D. Clarke to Ogden Goelet
https://digitalcommons.salve.edu/ochre-court/1104/thumbnail.jp
MgB2 tunnel junctions and 19 K low-noise dc superconducting quantum interference devices
Point contact junctions made from two pieces of MgB2 can be adjusted to
exhibit either superconductor-insulator-superconductor (SIS) or
superconductor-normal metal-superconductor (SNS) current-voltage
characteristics. The SIS characteristics are in good agreement with the
standard tunneling model for s-wave superconductors, and yield an energy gap of
(2.02 +/- 0.08) meV. The SNS characteristics are in good agreement with the
predictions of the resistively-shunted junction model. DC Superconducting
QUantum Interference Devices made from two SNS junctions yield magnetic field
noise as low as 35 fT/Hz^{1/2} at 19 K.Comment: 4 pages, 4 figure
Can guidelines improve referral to elective surgical specialties for adults? A systematic review
Aim To assess effectiveness of guidelines for referral for
elective surgical assessment.
Method Systematic review with descriptive synthesis.
Data sources Medline, EMBASE, CINAHL and Cochrane
database up to 2008. Hand searches of journals and
websites.
Selection of studies Studies evaluated guidelines for
referral from primary to secondary care, for elective
surgical assessment for adults.
Outcome measures Appropriateness of referral (usually
measured as guideline compliance) including clinical
appropriateness, appropriateness of destination and of
pre-referral management (eg, diagnostic investigations),
general practitioner knowledge of referral
appropriateness, referral rates, health outcomes and
costs.
Results 24 eligible studies (5 randomised control trials,
6 cohort, 13 case series) included guidelines from UK,
Europe, Canada and the USA for referral for
musculoskeletal, urological, ENT, gynaecology, general
surgical and ophthalmological conditions. Interventions
varied from complex (âone-stop shopsâ) to simple
guidelines. Four randomized control trials reported
increases in appropriateness of pre-referral care
(diagnostic investigations and treatment). No evidence
was found for effects on practitioner knowledge. Mixed
evidence was reported on rates of referral and costs
(rates and costs increased, decreased or stayed the
same). Two studies reported on health outcomes finding
no change.
Conclusions Guidelines for elective surgical referral can
improve appropriateness of care by improving prereferral
investigation and treatment, but there is no
strong evidence in favour of other beneficial effects
80 Gb/s optimised pulse source using a gain-switched laser diode in conjunction with a nonlinearly chirped grating
The authors demonstrate the generation of transforms limited short optical pulses, which display excellent spectral and temporal qualities by employing a novel technology, based on an externally injected gain-switched laser in conjunction with a non-linearly chirped grating. Using this technique, 3.5 ps optical pulses, exhibiting a time bandwidth product of 0.45, are generated, which are suitable for use in high-speed 80 Gb/s OTDM communications systems
Heralded state preparation in a superconducting qubit
We demonstrate high-fidelity, quantum nondemolition, single-shot readout of a
superconducting flux qubit in which the pointer state distributions can be
resolved to below one part in 1000. In the weak excitation regime, continuous
measurement permits the use of heralding to ensure initialization to a fiducial
state, such as the ground state. This procedure boosts readout fidelity to
93.9% by suppressing errors due to spurious thermal population. Furthermore,
heralding potentially enables a simple, fast qubit reset protocol without
changing the system parameters to induce Purcell relaxation.Comment: 5 pages, 5 figure
Lippia
https://thekeep.eiu.edu/herbarium_specimens_byname/18921/thumbnail.jp
Preconditioning and triggering of offshore slope failures and turbidity currents revealed by most detailed monitoring yet at a fjord-head delta
Rivers and turbidity currents are the two most important sediment transport processes by volume on Earth. Various hypotheses have been proposed for triggering of turbidity currents offshore from river mouths, including direct plunging of river discharge, delta mouth bar flushing or slope failure caused by low tides and gas expansion, earthquakes and rapid sedimentation. During 2011, 106 turbidity currents were monitored at Squamish Delta, British Columbia. This enables statistical analysis of timing, frequency and triggers. The largest peaks in river discharge did not create hyperpycnal flows. Instead, delayed delta-lip failures occurred 8â11 h after flood peaks, due to cumulative delta top sedimentation and tidally-induced pore pressure changes. Elevated river discharge is thus a significant control on the timing and rate of turbidity currents but not directly due to plunging river water. Elevated river discharge and focusing of river discharge at low tides cause increased sediment transport across the delta-lip, which is the most significant of all controls on flow timing in this setting
Vitex mollis H.B. & K.
https://thekeep.eiu.edu/herbarium_specimens_byname/19376/thumbnail.jp
Lippia
https://thekeep.eiu.edu/herbarium_specimens_byname/18921/thumbnail.jp
- âŠ