8,559 research outputs found

    A moving mesh method for one-dimensional hyperbolic conservation laws

    Get PDF
    We develop an adaptive method for solving one-dimensional systems of hyperbolic conservation laws that employs a high resolution Godunov-type scheme for the physical equations, in conjunction with a moving mesh PDE governing the motion of the spatial grid points. Many other moving mesh methods developed to solve hyperbolic problems use a fully implicit discretization for the coupled solution-mesh equations, and so suffer from a significant degree of numerical stiffness. We employ a semi-implicit approach that couples the moving mesh equation to an efficient, explicit solver for the physical PDE, with the resulting scheme behaving in practice as a two-step predictor-corrector method. In comparison with computations on a fixed, uniform mesh, our method exhibits more accurate resolution of discontinuities for a similar level of computational work

    Collecting Data from Children Ages 9-13

    Get PDF
    Provides a summary of literature on common methods used to collect data, such as diaries, interviews, observational methods, and surveys. Analyzes age group-specific considerations, advantages, and drawbacks, with tips for improving data quality

    Development and Application of Wide Bandwidth Magneto-Resistive Sensor Based Eddy Current Probe

    Get PDF
    The integration of magneto-resistive sensors into eddy current probes can significantly expand the capabilities of conventional eddy current nondestructive evaluation techniques. The room temperature solid-state sensors have typical bandwidths in the megahertz range and resolutions of tens of microgauss. The low frequency sensitivity of magneto-resistive sensors has been capitalized upon in previous research to fabricate very low frequency eddy current sensors for deep flaw detection in multilayer conductors. In this work a modified probe design is presented to expand the capabilities of the device. The new probe design incorporates a dual induction source enabling operation from low frequency deep flaw detection to high frequency high resolution near surface material characterization. Applications of the probe for the detection of localized near surface conductivity anomalies are presented. Finite element modeling of the probe is shown to be in good agreement with experimental measurements

    Eddy Current System and Method for Crack Detection

    Get PDF
    An eddy current system and method enables detection of sub-surface damage in a cylindrical object. The invention incorporates a dual frequency, orthogonally wound eddy current probe mounted on a stepper motor-controlled scanning system. The system is designed to inspect for outer surface damage from the interior of the cylindrical object

    Separating signal from noise: the challenge of identifying useful biomarkers in sepsis

    Get PDF
    Abstract Sepsis diagnosis remains based largely on clinical presentation despite significant advances in the understanding of underlying pathophysiology and host-pathogen interactions. The systematic review article by Zonneveld and colleagues in the previous issue of Critical Care describes another potential avenue of study for using biomarkers for sepsis diagnosis and prognostication. Soluble leukocyte adhesion molecules and their associated sheddase enzymes vary in detectable levels and activity in patients in relation to immunologic status, age, and systemic inflammation, including in the setting of sepsis. Unfortunately, studies of these molecules as diagnostic or prognostic aids (or both) in sepsis have thus far been disappointing. Zonneveld and colleagues propose two potential avenues to enhance the performance characteristics of soluble adhesion molecules and their sheddases in sepsis diagnosis and prognosis: (a) identifying age-adjusted normal values for soluble leukocyte adhesion molecules and their sheddases and (b) investigating simultaneous measurement of both soluble adhesion molecules and sheddases in integrated sepsis evaluation schema. This commentary discusses the proposed solutions of Zonneveld and colleagues in more detail and outlines additional considerations that should be addressed in order to develop robust and valid diagnostic and prognostic tools for clinicians managing patients with sepsis.Peer Reviewe

    Si3N4 emissivity and the unidentified infrared bands

    Get PDF
    Infrared spectroscopy of warm (about 150 to 750 K), dusty astronomical sources has revealed a structured emission spectrum which can be diagnostic of the composition, temperature, and in some cases, even size and shape of the grains giving rise to the observed emission. The identifications of silicate emission in oxygen rich objects and SiC in carbon rich object are two examples of this type of analysis. Cometary spectra at moderate resolution have similarly revealed silicate emission, tying together interstellar and interplanetary dust. However, Goebel has pointed out that some astronomical sources appear to contain a different type of dust which results in a qualitatively different spectral shape in the 8 to 13 micron region. The spectra shown make it appear unlikely that silicon nitride can be identified as the source of the 8 to 13 micron emission in either NGC 6572 or Nova Aql 1982. The similarity between the general wavelength and shape of the 10 micron emission from some silicates and that from the two forms of silicon nitride reported could allow a mix of cosmic grains which include some silicon nitride if only the 8 to 13 micron data are considered

    Impact of Ranch and Market Factors on an Index of Agricultural Holding Period Returns

    Get PDF
    This study develops nominal and real holding period return indices for operating ranches. The indices contain two components, monthly ranch operating profit and capital appreciation. A regression model that determines the effect of various attributes on total market value is used to estimate capital appreciation, and a second model determines operating profit. The two different ranch data series are compared with United States Long Term Government Bonds, the S&P 500 Index and Small Capitalization Stocks. Both ranch indices show very low correlation with the S&P 500 Index and very low or negative betas. Further, both ranch series have excess actual nominal and real returns when compared to expected returns determined from the Capital Asset Pricing Model.

    Robust designs for Poisson regression models

    Get PDF
    We consider the problem of how to construct robust designs for Poisson regression models. An analytical expression is derived for robust designs for first-order Poisson regression models where uncertainty exists in the prior parameter estimates. Given certain constraints in the methodology, it may be necessary to extend the robust designs for implementation in practical experiments. With these extensions, our methodology constructs designs which perform similarly, in terms of estimation, to current techniques, and offers the solution in a more timely manner. We further apply this analytic result to cases where uncertainty exists in the linear predictor. The application of this methodology to practical design problems such as screening experiments is explored. Given the minimal prior knowledge that is usually available when conducting such experiments, it is recommended to derive designs robust across a variety of systems. However, incorporating such uncertainty into the design process can be a computationally intense exercise. Hence, our analytic approach is explored as an alternative

    Magnetoresistive flux focusing eddy current flaw detection

    Get PDF
    A giant magnetoresistive flux focusing eddy current device effectively detects deep flaws in thick multilayer conductive materials. The probe uses an excitation coil to induce eddy currents in conducting material perpendicularly oriented to the coil's longitudinal axis. A giant magnetoresistive (GMR) sensor, surrounded by the excitation coil, is used to detect generated fields. Between the excitation coil and GMR sensor is a highly permeable flux focusing lens which magnetically separates the GMR sensor and excitation coil and produces high flux density at the outer edge of the GMR sensor. The use of feedback inside the flux focusing lens enables complete cancellation of the leakage fields at the GMR sensor location and biasing of the GMR sensor to a location of high magnetic field sensitivity. In an alternate embodiment, a permanent magnet is positioned adjacent to the GMR sensor to accomplish the biasing. Experimental results have demonstrated identification of flaws up to 1 cm deep in aluminum alloy structures. To detect deep flaws about circular fasteners or inhomogeneities in thick multilayer conductive materials, the device is mounted in a hand-held rotating probe assembly that is connected to a computer for system control, data acquisition, processing and storage
    corecore