189 research outputs found

    Validation of the SenseWear armband in circuit resistance training with different loads

    Get PDF
    The use of the SenseWear™ armband (SWA), an objective monitor of physical activity, is a relatively new device used by researchers to measure energy expenditure. These monitors are practical, relatively inexpensive and easy-to-use. The aim of the present study was to assess the validity of SWAs for the measurement of energy expenditure (EE) in circuit resistance training (CRT) at three different intensities in moderately active, healthy subjects. The study subjects (17 females, 12 males) undertook CRT at 30, 50 and 70% of the 15 repetition maximum for each exercise component wearing an SWA as well as an Oxycon Mobile (OM) portable metabolic system (a gold standard method for measuring EE). The EE rose as exercise intensity increased, but was underestimated by the SWAs. For women, Bland-Altman plots showed a bias of 1.13 ± 1.48 METs and 32.1 ± 34.0 kcal in favour of the OM system, while for men values of 2.33 ± 1.82 METs and 75.8 ± 50.8 kcal were recorded

    Step detection and activity recognition accuracy of seven physical activity monitors

    Get PDF
    The aim of this study was to compare the seven following commercially available activity monitors in terms of step count detection accuracy: Movemonitor (Mc Roberts), Up (Jawbone), One (Fitbit), ActivPAL (PAL Technologies Ltd.), Nike+ Fuelband (Nike Inc.), Tractivity (Kineteks Corp.) and Sensewear Armband Mini (Bodymedia). Sixteen healthy adults consented to take part in the study. The experimental protocol included walking along an indoor straight walkway, descending and ascending 24 steps, free outdoor walking and free indoor walking. These tasks were repeated at three self-selected walking speeds. Angular velocity signals collected at both shanks using two wireless inertial measurement units (OPAL, ADPM Inc) were used as a reference for the step count, computed using previously validated algorithms. Step detection accuracy was assessed using the mean absolute percentage error computed for each sensor. The Movemonitor and the ActivPAL were also tested within a nine-minute activity recognition protocol, during which the participants performed a set of complex tasks. Posture classifications were obtained from the two monitors and expressed as a percentage of the total task duration. The Movemonitor, One, ActivPAL, Nike+ Fuelband and Sensewear Armband Mini underestimated the number of steps in all the observed walking speeds, whereas the Tractivity significantly overestimated step count. The Movemonitor was the best performing sensor, with an error lower than 2% at all speeds and the smallest error obtained in the outdoor walking. The activity recognition protocol showed that the Movemonitor performed best in the walking recognition, but had difficulty in discriminating between standing and sitting. Results of this study can be used to inform choice of a monitor for specific applications

    Does child weight influence how mothers report their feeding practices?

    Get PDF
    Objectives. The present study aimed to ascertain whether parental reports of their feeding practices are associated with independent observations of these behaviours, and whether the reliability of maternal report depends upon the child's weight. Methods. A total of 56 mothers and their children ate a lunch to satiety which was videotaped and coded for maternal use of control during feeding. Mothers also completed questionnaires about their feeding practices and children were weighed and measured. Results. Maternal reports of controlling feeding practices were poorly related to independent observations of these behaviours in the laboratory. However, there was a significant interaction between child BMI z score and observed pressure to eat in predicting maternally reported pressure to eat. There was also a significant interaction between child BMI z score and observed maternal restriction with food in predicting maternally reported restriction. When decomposed, these interactions suggested that only mothers of relatively underweight children were accurate at reporting their use of pressure to eat when compared to independent observations. For mothers of relatively overweight children there was a significant negative relationship between observed and reported restriction over food. Conclusions. Overall there was poor correspondence between maternal reports and independent observations of the use of controlling feeding practices. Further research is needed to replicate these findings and to ascertain whether parents who are inaccurate at reporting their use of these feeding practices are unaware that they are using controlling feeding practices or whether they are responding in socially desirable ways to questionnaires assessing their feeding behaviour. © 2011 Informa Healthcare

    Validity of physical activity monitors for assessing lower intensity activity in adults

    Get PDF
    Background: Accelerometers can provide accurate estimates of moderate-to-vigorous physical activity (MVPA). However, one of the limitations of these instruments is the inability to capture light activity within an acceptable range of error. The purpose of the present study was to determine the validity of different activity monitors for estimating energy expenditure (EE) of light intensity, semi-structured activities. Methods: Forty healthy participants wore a SenseWear Pro3 Armband (SWA, v.6.1), the SenseWear Mini, the Actiheart, ActiGraph, and ActivPAL monitors, while being monitored with a portable indirect calorimetry (IC). Participants engaged in a variety of low intensity activities but no formalized scripts or protocols were used during these periods. Results: The Mini and SWA overestimated total EE on average by 1.0% and 4.0%, respectively, while the AH, the GT3X, and the AP underestimated total EE on average by 7.8%, 25.5%, and 22.2%, respectively. The pattern-recognition monitors yielded non-significant differences in EE estimates during the semi-structured period (p = 0.66, p = 0.27, and p = 0.21 for the Mini, SWA, and AH, respectively). Conclusions: The SenseWear Mini provided more accurate estimates of EE during light to moderate intensity semi-structured activities compared to other activity monitors. This monitor should be considered when there is interest in tracking low intensity activities in groups of individuals.This research was funded by a grant from Bodymedia Inc. awarded to Dr. Greg Welk

    How much locomotive activity is needed for an active physical activity level: analysis of total step counts

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>Although physical activity recommendations for public health have focused on locomotive activity such as walking and running, it is uncertain how much these activities contribute to overall physical activity level (PAL). The purpose of the present study was to determine the contribution of locomotive activity to PAL using total step counts measured in a calorimeter study.</p> <p>Methods</p> <p>PAL, calculated as total energy expenditure divided by basal metabolic rate, was evaluated in 11 adult men using three different conditions for 24-hour human calorimeter measurements: a low-activity day (L-day) targeted at a low active level of PAL (1.45), and a high-frequency moderate activity day (M-day) or a high-frequency vigorous activity day (V-day) targeted at an active level of PAL (1.75). These subjects were permitted only light activities except prescribed activities. In a separate group of 41 adults, free-living PAL was evaluated using doubly-labeled water (DLW). In both experiments, step counts per day were also measured using an accelerometer.</p> <p>Results</p> <p>In the human calorimeter study, PAL and step counts were 1.42 ± 0.10 and 8,973 ± 543 steps/d (L-day), 1.82 ± 0.14 and 29,588 ± 1,126 steps/d (M-day), and 1.74 ± 0.15 and 23,755 ± 1,038 steps/d (V-day), respectively. In the DLW study, PAL and step counts were 1.73 ± 0.15 and 10,022 ± 2,605 steps/d, and there was no significant relationship between PAL and daily step counts.</p> <p>Conclusions</p> <p>These results indicate that an enormous number of steps are needed for an active level of PAL if individuals extend physical activity-induced energy expenditure by only locomotive activity. Therefore, non-locomotive activity such as household activity should also play a significant role in increasing PAL under free-living conditions.</p

    Dissecting Genetic Networks Underlying Complex Phenotypes: The Theoretical Framework

    Get PDF
    Great progress has been made in genetic dissection of quantitative trait variation during the past two decades, but many studies still reveal only a small fraction of quantitative trait loci (QTLs), and epistasis remains elusive. We integrate contemporary knowledge of signal transduction pathways with principles of quantitative and population genetics to characterize genetic networks underlying complex traits, using a model founded upon one-way functional dependency of downstream genes on upstream regulators (the principle of hierarchy) and mutual functional dependency among related genes (functional genetic units, FGU). Both simulated and real data suggest that complementary epistasis contributes greatly to quantitative trait variation, and obscures the phenotypic effects of many ‘downstream’ loci in pathways. The mathematical relationships between the main effects and epistatic effects of genes acting at different levels of signaling pathways were established using the quantitative and population genetic parameters. Both loss of function and “co-adapted” gene complexes formed by multiple alleles with differentiated functions (effects) are predicted to be frequent types of allelic diversity at loci that contribute to the genetic variation of complex traits in populations. Downstream FGUs appear to be more vulnerable to loss of function than their upstream regulators, but this vulnerability is apparently compensated by different FGUs of similar functions. Other predictions from the model may account for puzzling results regarding responses to selection, genotype by environment interaction, and the genetic basis of heterosis

    Foundations of Black Hole Accretion Disk Theory

    Get PDF
    This review covers the main aspects of black hole accretion disk theory. We begin with the view that one of the main goals of the theory is to better understand the nature of black holes themselves. In this light we discuss how accretion disks might reveal some of the unique signatures of strong gravity: the event horizon, the innermost stable circular orbit, and the ergosphere. We then review, from a first-principles perspective, the physical processes at play in accretion disks. This leads us to the four primary accretion disk models that we review: Polish doughnuts (thick disks), Shakura-Sunyaev (thin) disks, slim disks, and advection-dominated accretion flows (ADAFs). After presenting the models we discuss issues of stability, oscillations, and jets. Following our review of the analytic work, we take a parallel approach in reviewing numerical studies of black hole accretion disks. We finish with a few select applications that highlight particular astrophysical applications: measurements of black hole mass and spin, black hole vs. neutron star accretion disks, black hole accretion disk spectral states, and quasi-periodic oscillations (QPOs).Comment: 91 pages, 23 figures, final published version available at http://www.livingreviews.org/lrr-2013-

    Child Fitness and Father’s BMI Are Important Factors in Childhood Obesity: A School Based Cross-Sectional Study

    Get PDF
    BACKGROUND: This study examines obesity and factors associated with obesity in children aged 11-13 years in the UK. METHODS: 1147 children from ten secondary schools participated in a health survey that included blood samples, fitness test and anthropometric measures. Factors associated with obesity were examined using multilevel logistic regression. FINDINGS: Of the children examined (490 male; 657 female) a third were overweight, 1 in 6 had elevated blood pressure, more than 1 in 10 had high cholesterol, 58% consumed more fat than recommended, whilst 37% were classified as unfit. Children in deprived areas had a higher proportion of risk factors; for example, they had higher blood pressure (20% (deprived) compared to 11% (non-deprived), difference: 9.0% (95%CI: 4.7%-13.4%)). Obesity is associated with risk factors for heart disease and diabetes. Maintaining fitness is associated with a reduction in the risk factors for heart disease (high blood pressure and cholesterol) but not on risk factors for diabetes (insulin levels). In order of importance, the main risk factors for childhood obesity are being unfit, having an obese father, and being large at birth. CONCLUSION: The high proportion of children with risk factors suggests future interventions need to focus on community and policy change to shift the population norm rather than targeting the behaviour of high risk individuals. Interventions need to focus on mothers' lifestyle in pregnancy, fathers' health, as well as promoting fitness among children. Obesity was not associated with deprivation. Therefore, strategies should be adopted in both deprived and non deprived areas

    The morphometry of soft tissue insertions on the tibial plateau: Data acquisition and statistical shape analysis

    Get PDF
    This study characterized the soft tissue insertion morphometrics on the tibial plateau and their inter-relationships as well as variabilities. The outlines of the cruciate ligament and meniscal root insertions along with the medial and lateral cartilage on 20 cadaveric tibias (10 left and 10 right knees) were digitized and co-registered with corresponding CT-based 3D bone models. Generalized Procrustes Analysis was employed in conjunction with Principal Components Analysis to first create a geometric consensus based on tibial cartilage and then determine the means and variations of insertion morphometrics including shape, size, location, and inter-relationship measures. Step-wise regression analysis was conducted in search of parsimonious models relating the morphometric measures to the tibial plateau width and depth, and basic anthropometric and gender factors. The analyses resulted in statistical morphometric representations for Procrustes-superimposed cruciate ligament and meniscus insertions, and identified only a few moderate correlations (R 2: 0.37-0.49). The study provided evidence challenging the isometric scaling based on a single dimension frequently employed in related morphometric studies, and data for evaluating cruciate ligament reconstruction strategies in terms of re-creating the native anatomy and minimizing the risk of iatrogenic injury. It paved the way for future development of computer-aided personalized orthopaedic surgery applications improving the quality of care and patient safety, and biomechanical models with a better population or average representation
    corecore