29 research outputs found

    Microfluidic Production of Polymeric Core-Shell Microspheres for the Delayed Pulsatile Release of Bovine Serum Albumin as a Model Antigen

    Get PDF
    For many vaccines, multiple injections are required to confer protective immunity against targeted pathogens. These injections often consist of a primer administration followed by a booster administration of the vaccine a few weeks or months later. A single-injection vaccine formulation that provides for both administrations could greatly improve the convenience and vaccinee’s compliance. In this study, we developed parenterally injectable core-shell microspheres with a delayed pulsatile release profile that could serve as the booster in such a vaccine formulation. These microspheres contained bovine serum albumin (BSA) as the model antigen and poly(DL-lactide-co-glycolide) (PLGA) with various DL-lactide:glycolide monomer ratios as the shell material. Highly monodisperse particles with different particle characteristics were obtained using a microfluidic setup. All formulations exhibited a pulsatile in vitro release of BSA after an adjustable lag time. This lag time increased with the increasing lactide content of the polymer and ranged from 3 to 7 weeks. Shell thickness and bovine serum albumin loading had no effect on the release behavior, which could be ascribed to the degradation mechanism of the polymer, with bulk degradation being the main pathway. Co-injection of the core-shell microspheres together with a solution of the antigen that serves as the primer would allow for the desired biphasic release profile. Altogether, these findings show that injectable core-shell microspheres combined with a primer are a promising alternative for the current multiple-injection vaccines

    Microsphere-Based Rapamycin Delivery, Systemic Versus Local Administration in a Rat Model of Renal Ischemia/Reperfusion Injury

    Get PDF
    The increasing prevalence and treatment costs of kidney diseases call for innovative therapeutic strategies that prevent disease progression at an early stage. We studied a novel method of subcapsular injection of monodisperse microspheres, to use as a local delivery system of drugs to the kidney. We generated placebo- and rapamycin monodisperse microspheres to investigate subcapsular delivery of drugs. Using a rat model of acute kidney injury, subcapsular injection of placebo and rapamycin monodisperse microspheres (monospheres) was compared to subcutaneous injection, mimicking systemic administration. We did not find any adverse effects related to the delivery method. Irrespective of the injection site, a similar low dose of rapamycin was present in the circulation. However, only local intrarenal delivery of rapamycin from monospheres led to decreased macrophage infiltration and a significantly lower amount of myofibroblasts in the kidney, where systemic administration did not. Local delivery of rapamycin did cause a transient increase in the deposition of collagen I, but not of collagen III. We conclude that therapeutic effects can be increased when rapamycin is delivered subcapsularly by monospheres, which, combined with low systemic concentrations, may lead to an effective intrarenal delivery method

    Титульні сторінки та зміст

    Get PDF
    Kidney injury triggers fibrosis, the final common pathway of chronic kidney disease (CKD). The increase of CKD prevalence worldwide urgently calls for new therapies. Available systemic treatment such as rapamycin are associated with serious side effects. To study the potential of local antifibrotic therapy, we administered rapamycin-loaded microspheres under the kidney capsule of ureter-obstructed rats and assessed the local antifibrotic effects and systemic side effects of rapamycin. After 7 days, microsphere depots were easily identifiable under the kidney capsule. Both systemic and local rapamycin treatment reduced intrarenal mTOR activity, myofibroblast accumulation, expression of fibrotic genes, and T-lymphocyte infiltration. Upon local treatment, inhibition of mTOR activity and reduction of myofibroblast accumulation were limited to the immediate vicinity of the subcapsular pocket, while reduction of T-cell infiltration was widespread. In contrast to systemically administered rapamycin, local treatment did not induce off target effects such as weight loss. Thus subcapsular delivery of rapamycin-loaded microspheres successfully inhibited local fibrotic response in UUO with less systemic effects. Therapeutic effect of released rapamycin was most prominent in close vicinity to the implanted microspheres. (C) 2014 Elsevier Ltd. All rights reserved

    Pediatric trauma and emergency surgery: an international cross-sectional survey among WSES members

    Get PDF
    Background: In contrast to adults, the situation for pediatric trauma care from an international point of view and the global management of severely injured children remain rather unclear. The current study investigates structural management of pediatric trauma in centers of different trauma levels as well as experiences with pediatric trauma management around the world. Methods: A web-survey had been distributed to the global mailing list of the World Society of Emergency Surgery from 10/2021-03/2022, investigating characteristics of respondents and affiliated hospitals, case-load of pediatric trauma patients, capacities and infrastructure for critical care in children, trauma team composition, clinical work-up and individual experiences with pediatric trauma management in response to patients´ age. The collaboration group was subdivided regarding sizes of affiliated hospitals to allow comparisons concerning hospital volumes. Comparable results were conducted to statistical analysis. Results: A total of 133 participants from 34 countries, i.e. 5 continents responded to the survey. They were most commonly affiliated with larger hospitals (> 500 beds in 72.9%) and with level I or II trauma centers (82.0%), respectively. 74.4% of hospitals offer unrestricted pediatric medical care, but only 63.2% and 42.9% of the participants had sufficient experiences with trauma care in children ≤ 10 and ≤ 5 years of age (p = 0.0014). This situation is aggravated in participants from smaller hospitals (p < 0.01). With regard to hospital size (≤ 500 versus > 500 in-hospital beds), larger hospitals were more likely affiliated with advanced trauma centers, more elaborated pediatric intensive care infrastructure (p < 0.0001), treated children at all ages more frequently (p = 0.0938) and have higher case-loads of severely injured children < 12 years of age (p = 0.0009). Therefore, the majority of larger hospitals reserve either pediatric surgery departments or board-certified pediatric surgeons (p < 0.0001) and in-hospital trauma management is conducted more multi-disciplinarily. However, the majority of respondents does not feel prepared for treatment of severe pediatric trauma and call for special educational and practical training courses (overall: 80.2% and 64.3%, respectively). Conclusions: Multi-professional management of pediatric trauma and individual experiences with severely injured children depend on volumes, level of trauma centers and infrastructure of the hospital. However, respondents from hospitals at all levels of trauma care complain about an alarming lack of knowledge on pediatric trauma management

    Rechtspraak op verzoekschriften

    No full text
    "Stellingen": [3] p. laid in."Lijst van enkele afkortingen en van werken, alleen met den naam vaden schrijver aangehaald": 3 preceding p. [1].Proefschrift--Utrecht.Mode of access: Internet

    SHOTGUN: converting words into triplets A hybrid approach to grapheme-phoneme conversion in Dutch

    No full text
    Item does not contain fulltext32 p

    Spellingdossier /

    No full text
    1. Spellingrapport2. SpellingbesluitVan Elslander, Antoni

    Protection of stapled colorectal anastomoses with a biodegradable device:the C-Seal feasibility study

    No full text
    BACKGROUND: A colorectal anastomotic leak can be life-threatening. We have assessed the feasibility of a new intraluminal biodegradable bypass device that we designed to avoid anastomotic leakage and the necessity of a temporary stoma.METHODS: Fifteen patients underwent colorectal surgery. Before performing the anastomosis in a standard way, the C-Seal (Polyganics BV, Groningen, The Netherlands) was glued to the anvil of the circular stapler. Consequently, the bypass was fixated in the staple row just proximal of the simultaneously made anastomosis. A water-soluble contrast enema was performed after 1 week.RESULTS: The sheath was well compatible with the standard stapler device and easy to use. All donuts remained intact. No radiologic or clinical leaks were observed after surgery.CONCLUSIONS: This pilot study shows that the C-Seal can be applied successfully in colorectal surgery. Further investigation with large numbers of patients is now necessary to assess the efficacy of the C-Seal as a protective device. (C) 2011 Elsevier Inc. All rights reserved.</p
    corecore