2,623 research outputs found

    Classification dynamique d'un flux documentaire : une évaluation statique préalable de l'algorithme GERMEN.

    No full text
    International audienceData-stream clustering is an ever-expanding subdomain of knowledge extraction. Most of the past and present research effort aims at efficient scaling up for the huge data repositories. Our approach focuses on qualitative improvement, mainly for "weak signals" detection and precise tracking of topical evolutions in the framework of information watch - though scalability is intrinsically guaranteed in a possibly distributed implementation. Our GERMEN algorithm exhaustively picks up the whole set of density peaks of the data at time t, by identifying the local perturbations induced by the current document vector, such as changing cluster borders, or new/vanishing clusters. Optimality yields from the uniqueness 1) of the density landscape for any value of our zoom parameter, 2) of the cluster allocation operated by our border propagation rule. This results in a rigorous independence from the data presentation ranking or any initialization parameter. We present here as a first step the only assessment of a static view resulting from one year of the CNRS/INIST Pascal database in the field of geotechnics

    The convention center in secondary cities

    Get PDF
    Thesis (M.S.)--Massachusetts Institute of Technology, Dept. of Architecture, 1989.Includes bibliographical references (leaves 65-67).by Alain Robert Vallès, Joel Thomas Warshauer.M.S

    The “pharmaceuticalisation” of life

    Get PDF

    Attention, Awareness, and the Perception of Auditory Scenes

    Get PDF
    Auditory perception and cognition entails both low-level and high-level processes, which are likely to interact with each other to create our rich conscious experience of soundscapes. Recent research that we review has revealed numerous influences of high-level factors, such as attention, intention, and prior experience, on conscious auditory perception. And recently, studies have shown that auditory scene analysis tasks can exhibit multistability in a manner very similar to ambiguous visual stimuli, presenting a unique opportunity to study neural correlates of auditory awareness and the extent to which mechanisms of perception are shared across sensory modalities. Research has also led to a growing number of techniques through which auditory perception can be manipulated and even completely suppressed. Such findings have important consequences for our understanding of the mechanisms of perception and also should allow scientists to precisely distinguish the influences of different higher-level influences

    Biological Markers of Auditory Gap Detection in Young, Middle-Aged, and Older Adults

    Get PDF
    The capability of processing rapid fluctuations in the temporal envelope of sound declines with age and this contributes to older adults' difficulties in understanding speech. Although, changes in central auditory processing during aging have been proposed as cause for communication deficits, an open question remains which stage of processing is mostly affected by age related changes. We investigated auditory temporal resolution in young, middle-aged, and older listeners with neuromagnetic evoked responses to gap stimuli with different leading marker and gap durations. Signal components specific for processing the physical details of sound stimuli as well as the auditory objects as a whole were derived from the evoked activity and served as biological markers for temporal processing at different cortical levels. Early oscillatory 40-Hz responses were elicited by the onsets of leading and lagging markers and indicated central registration of the gap with similar amplitude in all three age groups. High-gamma responses were predominantly related to the duration of no-gap stimuli or to the duration of gaps when present, and decreased in amplitude and phase locking with increasing age. Correspondingly, low-frequency activity around 200 ms and later was reduced in middle aged and older participants. High-gamma band, and long-latency low-frequency responses were interpreted as reflecting higher order processes related to the grouping of sound items into auditory objects and updating of memory for these objects. The observed effects indicate that age-related changes in auditory acuity have more to do with higher-order brain functions than previously thought

    Use of a beta microprobe system to measure arterial input function in PET via an arteriovenous shunt in rats

    Get PDF
    Kinetic modeling of physiological function using imaging techniques requires the accurate measurement of the time-activity curve of the tracer in plasma, known as the arterial input function (IF). The measurement of IF can be achieved through manual blood sampling, the use of small counting systems such as beta microprobes, or by derivation from PET images. Previous studies using beta microprobe systems to continuously measure IF have suffered from high background counts. In the present study, a light-insensitive beta microprobe with a temporal resolution of up to 1 s was used in combination with a pump-driven femoral arteriovenous shunt to measure IF in rats. The shunt apparatus was designed such that the placement of the beta microprobe was highly reproducible. The probe-derived IF was compared to that obtained from manual sampling at 5-s intervals and IF derived from a left ventricle VOI in a dynamic PET image of the heart. Probe-derived IFs were very well matched to that obtained by "gold standard" manual blood sampling, but with an increased temporal resolution of up to 1 s. The area under the curve (AUC) ratio between probe- and manually derived IFs was 1.07 ± 0.05 with a coefficient of variation of 0.04. However, image-derived IFs were significantly underestimated compared to the manually sampled IFs, with an AUC ratio of 0.76 ± 0.24 with a coefficient of variation of 0.32. IF derived from the beta microprobe accurately represented the IF as measured by blood sampling, was reproducible, and was more accurate than an image-derived technique. The use of the shunt removed problems of tissue-background activity, and the use of a light-tight probe with minimal gamma sensitivity refined the system. The probe/shunt apparatus can be used in both microprobe and PET studies

    The Next Generation Virgo Cluster Survey. IX. Estimating the Efficiency of Galaxy Formation on the Lowest-Mass Scales

    Full text link
    The Next Generation Virgo Cluster Survey has recently determined the luminosity function of galaxies in the core of the Virgo cluster down to unprecedented magnitude and surface brightness limits. Comparing simulations of cluster formation to the derived central stellar mass function, we attempt to estimate the stellar-to-halo-mass ratio (SHMR) for dwarf galaxies, as it would have been before they fell into the cluster. This approach ignores several details and complications, e.g., the contribution of ongoing star formation to the present-day stellar mass of cluster members, and the effects of adiabatic contraction and/or violent feedback on the subhalo and cluster potentials. The final results are startlingly simple, however; we find that the trends in the SHMR determined previously for bright galaxies appear to extend down in a scale-invariant way to the faintest objects detected in the survey. These results extend measurements of the formation efficiency of field galaxies by two decades in halo mass, or five decades in stellar mass, down to some of the least massive dwarf galaxies known, with stellar masses of 105M\sim 10^5 M_\odot.Comment: 18 pages, 12 figures; published in ApJ July 1st 201
    corecore