129 research outputs found

    Photon counting strategies with low light level CCDs

    Full text link
    Low light level charge coupled devices (L3CCDs) have recently been developed, incorporating on-chip gain. They may be operated to give an effective readout noise much less than one electron by implementing an on-chip gain process allowing the detection of individual photons. However, the gain mechanism is stochastic and so introduces significant extra noise into the system. In this paper we examine how best to process the output signal from an L3CCD so as to minimize the contribution of stochastic noise, while still maintaining photometric accuracy. We achieve this by optimising a transfer function which translates the digitised output signal levels from the L3CCD into a value approximating the photon input as closely as possible by applying thresholding techniques. We identify several thresholding strategies and quantify their impact on photon counting accuracy and effective signal-to-noise. We find that it is possible to eliminate the noise introduced by the gain process at the lowest light levels. Reduced improvements are achieved as the light level increases up to about twenty photons per pixel and above this there is negligible improvement. Operating L3CCDs at very high speeds will keep the photon flux low, giving the best improvements in signal-to-noise ratio.Comment: 7 pages, accepted by MNRA

    Development of EM-CCD-based X-ray detector for synchrotron applications

    Get PDF
    A high speed, low noise camera system for crystallography and X-ray imaging applications is developed and successfully demonstrated. By coupling an electron-multiplying (EM)-CCD to a 3:1 fibre-optic taper and a CsI(Tl) scintillator, it was possible to detect hard X-rays. This novel approach to hard X-ray imaging takes advantage of sub-electron equivalent readout noise performance at high pixel readout frequencies of EM-CCD detectors with the increase in the imaging area that is offered through the use of a fibre-optic taper. Compared with the industry state of the art, based on CCD camera systems, a high frame rate for a full-frame readout (50 ms) and a lower readout noise (<1 electron root mean square) across a range of X-ray energies (6–18 keV) were achieved

    Three-Dimensional Seismic Imaging of Ancient Submarine Lava Flows : An Example From the Southern Australian Margin

    Get PDF
    This work comprises a part of the Great Australian Bight Deepwater Marine Program (GABDMP) for funding this project. The GABDMP is a CSIRO research program, sponsored by Chevron Australia the results of which will be made publicly available. 3D seismic data was gratefully provided by TGS. IHS are thanked for access to seismic interpretation software. Spectral decomposition was carried out using Foster-Findlay Associates Geoteric Software. Sverre Planke and Tracy Gregg are thanked for constructive reviews.Peer reviewedPublisher PD

    Electron Multiplying CCDs

    Get PDF
    Electron multiplying CCD (EMCCD) technology has found important initial applications in low light surveillance and photon starved scientific instrumentation. This paper provides a description of the technology and discusses the attributes of the EMCCD which may make it useful for other detectors, particularly those which are photon starve

    Combining thermal imaging with photogrammetry of an active volcano using UAV : an example from Stromboli, Italy

    Get PDF
    The authors would like to thank the Istituto Nazionale di Geofisica e Vulcanologia – Sezione di Catania (INGV‐CT) for granting permission to conduct the UAV surveys over the Stromboli volcano. This work was supported by the School for Early Career Researchers at the University of Aberdeen, UK. Dougal Jerram is partly funded through a Norwegian Research Council Centres of Excellence project (project number 223272, CEED). The team would like to thank Angelo Cristaudo for logistical help during the fieldwork efforts on Stromboli.Peer reviewedPostprin

    Compact CMOS camera demonstrator (C3D) for Ukube-1

    Get PDF
    The Open University, in collaboration with e2v technologies and XCAM Ltd, have been selected to fly an EO (Earth Observation) technology demonstrator and in-orbit radiation damage characterisation instrument on board the UK Space Agency's UKube-1 pilot Cubesat programme. Cubesat payloads offer a unique opportunity to rapidly build and fly space hardware for minimal cost, providing easy access to the space environment. Based around the e2v 1.3 MPixel 0.18 micron process eye-on-Si CMOS devices, the instrument consists of a radiation characterisation imager as well as a narrow field imager (NFI) and a wide field imager (WFI). The narrow and wide field imagers are expected to achieve resolutions of 25 m and 350 m respectively from a 650 km orbit, providing sufficient swathe width to view the southern UK with the WFI and London with the NFI. The radiation characterisation experiment has been designed to verify and reinforce ground based testing that has been conducted on the e2v eye-on-Si family of devices and includes TEC temperature control circuitry as well as RADFET in-orbit dosimetry. Of particular interest are SEU and SEL effects. The novel instrument design allows for a wide range of capabilities within highly constrained mass, power and space budgets providing a model for future use on similarly constrained missions, such as planetary rovers. Scheduled for launch in December 2011, this 1 year low cost programme should not only provide valuable data and outreach opportunities but also help to prove flight heritage for future missions

    The Interface Region Imaging Spectrograph (IRIS)

    Get PDF
    The Interface Region Imaging Spectrograph (IRIS) small explorer spacecraft provides simultaneous spectra and images of the photosphere, chromosphere, transition region, and corona with 0.33-0.4 arcsec spatial resolution, 2 s temporal resolution and 1 km/s velocity resolution over a field-of-view of up to 175 arcsec x 175 arcsec. IRIS was launched into a Sun-synchronous orbit on 27 June 2013 using a Pegasus-XL rocket and consists of a 19-cm UV telescope that feeds a slit-based dual-bandpass imaging spectrograph. IRIS obtains spectra in passbands from 1332-1358, 1389-1407 and 2783-2834 Angstrom including bright spectral lines formed in the chromosphere (Mg II h 2803 Angstrom and Mg II k 2796 Angstrom) and transition region (C II 1334/1335 Angstrom and Si IV 1394/1403 Angstrom). Slit-jaw images in four different passbands (C II 1330, Si IV 1400, Mg II k 2796 and Mg II wing 2830 Angstrom) can be taken simultaneously with spectral rasters that sample regions up to 130 arcsec x 175 arcsec at a variety of spatial samplings (from 0.33 arcsec and up). IRIS is sensitive to emission from plasma at temperatures between 5000 K and 10 MK and will advance our understanding of the flow of mass and energy through an interface region, formed by the chromosphere and transition region, between the photosphere and corona. This highly structured and dynamic region not only acts as the conduit of all mass and energy feeding into the corona and solar wind, it also requires an order of magnitude more energy to heat than the corona and solar wind combined. The IRIS investigation includes a strong numerical modeling component based on advanced radiative-MHD codes to facilitate interpretation of observations of this complex region. Approximately eight Gbytes of data (after compression) are acquired by IRIS each day and made available for unrestricted use within a few days of the observation.Comment: 53 pages, 15 figure

    Breakup volcanism and plate tectonics in the NW Atlantic

    Get PDF
    The seismic, magnetic, and gravity data presented in this study were provided by TGS. Seismic interpretation was done using HS Kingdom software. Grid interpolations and map compilations were established using Geosoft Oasis Montaj and ArcGis softwares. We would like thank Craig Magee, Alexander Lewis Peace, the Editor and the Associated Editor for helpful comments and guidance that improved the paper. We acknowledge the support from the Research Council of Norway through its Center of Excellence funding scheme, project 223272 (CEED).Peer reviewedPostprin

    Stress Field Interactions Between Overlapping Shield Volcanoes : Borehole Breakout Evidence From the Island of Hawai'i, USA

    Get PDF
    Acknowledgments: This PTA2 borehole investigation was funded by the International Continental Scientific Drilling Program (ICDP) and by VMAPP (Volcanic Margin Petroleum Prospectivity) project (VBPR/DougalEARTH/TGS) in collaboration with the Humu'ula Groundwater Research Project. D. A. J. and S. P. are partly funded through a Norwegian Research Council Centres of Excellence project (project number 223272, CEED). We thank Marco Groh for the logging operations. We thank two anonymous reviewers for the comments and suggestions. We are particularly grateful to the Associate Editor Mike Poland for his valuable comments and his critical review that greatly improved the manuscript.Peer reviewedPublisher PD
    corecore