79 research outputs found

    Cardiovascular disease biomarkers are associated with declining renal function in type 2 diabetes

    Get PDF
    Aims/hypothesis: We investigated whether biochemical cardiovascular risk factors and/or markers of subclinical cardiovascular disease were associated with the development of reduced renal function in people with type 2 diabetes. Methods: A cohort of 1066 Scottish men and women aged 60–74 years with type 2 diabetes from the Edinburgh Type 2 Diabetes Study were followed up for a median of 6.7 years. New-onset reduced renal function was defined as two eGFRs <60 ml−1 min−1 (1.73 m)−2 at least 3 months apart with a > 25% decline from baseline eGFR. Ankle brachial pressure index (ABI), N-terminal pro-B-type natriuretic peptide (NT-proBNP) and high-sensitivity troponin T (hsTnT) were measured at baseline. Pulse wave velocity (PWV) and carotid intima media thickness were measured 1 year into follow-up. Data were analysed using Cox proportional hazards models. Results: A total of 119 participants developed reduced renal function during follow-up. ABI, PWV, NT-proBNP and hsTnT were all associated with onset of decline in renal function following adjustment for age and sex. These associations were attenuated after adjustment for additional diabetes renal disease risk factors (systolic BP, baseline eGFR, albumin:creatinine ratio and smoking pack-years), with the exception of hsTnT which remained independently associated (HR 1.51 [95% CI 1.22, 1.87]). Inclusion of hsTnT in a predictive model improved the continuous net reclassification index by 0.165 (0.008, 0.286). Conclusions/interpretation: Our findings demonstrate an association between hsTnT, a marker of subclinical cardiac ischaemia, and subsequent renal function decline. Further research is required to establish the predictive value of hsTnT and response to intervention

    Alpha-fetoprotein detection of hepatocellular carcinoma leads to a standardized analysis of dynamic AFP to improve screening based detection

    Get PDF
    Detection of hepatocellular carcinoma (HCC) through screening can improve outcomes. However, HCC surveillance remains costly, cumbersome and suboptimal. We tested whether and how serum Alpha-Fetoprotein (AFP) should be used in HCC surveillance. Record linkage, dedicated pathways for management and AFP data-storage identified i) consecutive highly characterised cases of HCC diagnosed in 2009-14 and ii) a cohort of ongoing HCC-free patients undergoing regular HCC surveillance from 2009. These two well-defined Scottish patient cohorts enabled us to test the utility of AFP surveillance. Of 04 cases of HCC diagnosed over 6 years, 42% (129) were identified by a dedicated HCC surveillance programme. Of these 129, 47% (61) had a detectable lesion first identified by screening ultrasound (US) but 38% (49) were prompted by elevated AFP. Despite pre-HCC diagnosis AFP >20kU/L being associated with poor outcome, 'AFP-detected' tumours were offered potentially curative management as frequently as 'US-detected' HCCs; and had comparable survival. Linearity of serial log10 -transformed AFPs in HCC cases and in the screening 'HCC-free' cohort (n = 1509) provided indicators of high-risk AFP behaviour in HCC cases. An algorithm was devised in static mode, then tested dynamically. A case/control series in hepatitis C related disease demonstrated highly significant detection (p-5) of patients at high risk of developing HCC. These data support the use of AFP in HCC surveillance. We show proof-of-principle that an automated and further refineable algorithmic interpretation of AFP can identify patients at higher risk of HCC. This approach could provide a cost-effective, user-friendly and much needed addition to US surveillance

    Evaluation of SARS-CoV-2 antibody point of care devices in the laboratory and clinical setting

    Get PDF
    SARS-CoV-2 antibody tests have been marketed to diagnose previous SARS-CoV-2 infection and as a test of immune status. There is a lack of evidence on the performance and clinical utility of these tests. We aimed to carry out an evaluation of 14 point of care (POC) SARS-CoV-2 antibody tests. Serum from participants with previous RT-PCR (real-time polymerase chain reaction) confirmed SARS-CoV-2 infection and pre-pandemic serum controls were used to determine specificity and sensitivity of each POC device. Changes in sensitivity with increasing time from infection were determined on a cohort of study participants. Corresponding neutralising antibody status was measured to establish whether the detection of antibodies by the POC device correlated with immune status. Paired capillary and serum samples were collected to ascertain whether POC devices performed comparably on capillary samples. Sensitivity and specificity varied between the POC devices and in general did not meet the manufacturers’ reported performance characteristics, which signifies the importance of independent evaluation of these tests. The sensitivity peaked at ≥20 days following onset of symptoms, however sensitivity of 3 of the POC devices evaluated at extended time points showed that sensitivity declined with time. This was particularly marked at >140 days post infection. This is relevant if the tests are to be used for sero-prevalence studies. Neutralising antibody data showed that positive antibody results on POC devices did not necessarily confer high neutralising antibody titres, and that these POC devices cannot be used to determine immune status to the SARS-CoV-2 virus. Comparison of paired serum and capillary results showed that there was a decline in sensitivity using capillary blood. This has implications in the utility of the tests as they are designed to be used on capillary blood by the general population

    Comparison of SARS-CoV-2 serological assays for use in epidemiological surveillance in Scotland

    Get PDF
    Background: Sero-surveillance of SARS-CoV-2 is crucial to monitoring levels of population exposure and informing public health responses, but may be influenced by variability in performance between available assays. Methods: Five commercial immunoassays and a neutralising activity assay were used to detect antibodies to SARS-CoV-2 in routine primary care and paediatric samples collected during the first wave of the pandemic in NHS Lothian, Scotland as part of ongoing surveillance efforts. For each assay, sensitivity and specificity was calculated relative to consensus results (majority of immunoassays positive = overall positive) and neutralising activity. Quantitative correlation was performed between serological and neutralising titres. Results: Seroprevalence ranged from 3.4–7.3 % in primary care patients and 3–5.9 % in paediatric patients according to different immunoassays. Neutralising activity was detectable in 2.8 % and 1.3 % respectively. Relative assay performance changed depending on comparison to immunoassay consensus versus neutralising activity and qualititative versus quantitative agreement. Cross-reactivity with endemic seasonal coronaviruses was confirmed by neutralising assay in false positives for one immunoassay. Presence of false positives for another assay was found specifically in paediatric but not adult samples. Conclusions: Five serological assays show variable accuracy when applied to the general population, impacting seroprevalence estimates. Assay performance may also vary in detection of protective neutralising antibody levels. These aspects should be considered in assay selection and interpretation in epidemiological studies

    Longitudinal variation in SARS-CoV-2 antibody levels and emergence of viral variants:a serological analysis

    Get PDF
    BACKGROUND: Serological assays are being used to monitor antibody responses in individuals who had SARS-CoV-2 infection and those who received a COVID-19 vaccine. We aimed to determine whether such assays can predict neutralising antibody titres as antibody levels wane and viral variants emerge. METHODS: We measured antibody levels in serum samples from a cohort of 112 participants with SARS-CoV-2 infection using ten high-throughput serological tests and functional neutralisation assays. Serum samples were taken at baseline and at up to four subsequent visits. We assessed the effects of time and spike protein sequence variation on the performance and predictive value of the various assays. We did correlation analyses for individual timepoints using non-parametric Spearman correlation, and differences between timepoints were determined by use of a two-tailed Wilcoxon matched-pairs signed rank test. FINDINGS: Neutralising antibody titres decreased over the first few months post-infection but stabilised thereafter, at about 30% of the level observed shortly after infection. Serological assays commonly used to measure antibodies against SARS-CoV-2 displayed a range of sensitivities that declined to varying extents over time. Quantitative measurements generated by serological assays based on the spike protein were better at predicting neutralising antibody titres than those based on nucleocapsid, but performance was variable, and manufacturer positivity thresholds were not able to predict the presence or absence of detectable neutralising activity. Although we observed some deterioration in correlation between serological measurements and functional neutralisation activity, some assays maintained an ability to predict neutralising titres, even against variants of concern. INTERPRETATION: The ability of high-throughput serological assays to predict neutralising antibody titres is likely to be crucial for evaluation of immunity at the population scale. These data can facilitate the selection of the most suitable assays as surrogates of functional neutralising activity and suggest that such measurements might be useful in clinical practice. FUNDING: US National Institutes of Health and National Health Service Research Scotland BioResource

    Diagnostic performance of the combined nasal and throat swab in patients admitted to hospital with suspected COVID-19.

    Get PDF
    BACKGROUND: Accurate diagnosis in patients with suspected coronavirus disease 2019 (COVID-19) is essential to guide treatment and limit spread of the virus. The combined nasal and throat swab is used widely, but its diagnostic performance is uncertain. METHODS: In a prospective, multi-centre, cohort study conducted in secondary and tertiary care hospitals in Scotland, we evaluated the combined nasal and throat swab with reverse transcriptase-polymerase chain reaction (RT-PCR) for severe acute respiratory syndrome coronavirus-2 (SARS-CoV-2) in consecutive patients admitted to hospital with suspected COVID-19. Diagnostic performance of the index and serial tests was evaluated for a primary outcome of confirmed or probable COVID-19, and a secondary outcome of confirmed COVID-19 on serial testing. The diagnosis was adjudicated by a panel, who recorded clinical, laboratory and radiological features blinded to the test results. RESULTS: We enrolled 1368 consecutive patients (median age 68 [interquartile range, IQR 53-80] years, 47% women) who underwent a total of 3822 tests (median 2 [IQR 1-3] tests per patient). The primary outcome occurred in 36% (496/1368), of whom 65% (323/496) and 35% (173/496) had confirmed and probable COVID-19, respectively. The index test was positive in 255/496 (51%) patients with the primary outcome, giving a sensitivity and specificity of 51.4% (95% confidence interval [CI] 48.8 to 54.1%) and 99.5% (95% CI 99.0 to 99.8%). Sensitivity increased in those undergoing 2, 3 or 4 tests to 60.1% (95% CI 56.7 to 63.4%), 68.3% (95% CI 64.0 to 72.3%) and 77.6% (95% CI 72.7 to 81.9%), respectively. The sensitivity of the index test was 78.9% (95% CI 74.4 to 83.2%) for the secondary outcome of confirmed COVID-19 on serial testing. CONCLUSIONS: In patients admitted to hospital, a single combined nasal and throat swab with RT-PCR for SARS-CoV-2 has excellent specificity, but limited diagnostic sensitivity for COVID-19. Diagnostic performance is significantly improved by repeated testing

    Theory and description in African Linguistics: Selected papers from the 47th Annual Conference on African Linguistics

    Get PDF
    The papers in this volume were presented at the 47th Annual Conference on African Linguistics at UC Berkeley in 2016. The papers offer new descriptions of African languages and propose novel theoretical analyses of them. The contributions span topics in phonetics, phonology, syntax, semantics, and pragmatics and reflect the typological and genetic diversity of languages in Africa. Four papers in the volume examine Areal Features and Linguistic Reconstruction in Africa, and were presented at a special workshop on this topic held alongside the general session of ACAL
    • …
    corecore