74 research outputs found

    Transcatheter aortic valve resection: new mechanical devices

    Get PDF
    Background To improve periprocedural outcomes of transcatheter aortic valve implantation (TAVI), transcatheter mechanical resection devices were tested for prior ablation of the aortic cusps. Methods Three mechanical transcatheter resection devices were tested in a series of native porcine (n=30) and reassembled calcified human valves (n=54). The resection time, the resected valve area, the number of released cusps, and the degree of surrounding tissue damage were measured. Afterwards, postmortem transapical-transcatheter-resections of the aortic valve in two humans were performed. Results In the native porcine hearts, the Aesculap II device demonstrated significantly shorter resection time compared to the R&R II and the Randstad devices (6.5±2.0 vs. 28.6±24.1 vs. 23.3±14.4 sec; P=0.001). However, it created more lesions in the surrounding tissue (P=0.002). The R&R II achieved a smaller number of resected cusps than the other two devices (2.7±0.7 vs. 1.1±0.7 vs. 2.4±0.5; P<0.001, respectively). It also resected a smaller area of the aortic valve (306.5±149.2 vs. 106.7±29.6 vs. 256.8±81.3 mm2; P=0.09) but a larger mean area of the resected fragments (110.3±41.5 vs. 160.7±29.6 vs. 111.5±43.9 mm2; P=0.01). The resection of the reassembled human valves demonstrated the same results between the devices regarding resection time (P=0.001) and resected area (P=0.016), but not fragment sizes (P=0.610). Finally, transapical-transcatheter-resection of aortic valve was performed in two cadavers. Conclusions Transcatheter aortic valve resection is feasible with variable aortic leaflet resection times and mild risk of lesions of the surrounding tissue

    Transcatheter heart valve commissural alignment: an updated review

    Get PDF
    Transcatheter aortic valve replacement (TAVR) indications recently extended to lower surgical risk patients with longer life expectancy. Commissural alignment (CA) is one of the emerging concepts and is becoming one of the cornerstones of the TAVR procedure in a patient with increased longevity. Indeed, CA may improve transcatheter heart valve (THV) hemodynamics, future coronary access, and repeatability. The definition of CA has been recently standardized by the ALIGN-TAVR consortium using a four-tier scale based on CT analysis. Progress has been made during the index TAVR procedure to optimize CA, especially with self-expandable platforms. Indeed, specific delivery catheter orientation, THV rotation, and computed-tomography-derived views have been proposed to achieve a reasonable degree of CA. Recent data demonstrate feasibility, safety, and a significant reduction in coronary overlap using these techniques, especially with self-expandable platforms. This review provides an overview of THV CA including assessment methods, alignment techniques during the index TAVR procedure with different THV platforms, the clinical impact of commissural misalignment, and challenging situations for CA

    Dedicated plug based closure for large bore access -The MARVEL prospective registry

    Get PDF
    Objectives To study safety and performance of the MANTA Vascular closure device (VCD) under real world conditions in 10 centers. Background The MANTA is a novel plug-based device for large bore arteriotomy closure. Methods We included all eligible patients who underwent transfemoral large bore percutaneous procedures. Exclusion criteria were per operator's discretion and included severe calcification or marked tortuosity of the access vessel, presence of marked obesity/cachexia or a systolic blood pressure above 180 mmHg. The primary performance endpoint was time to hemostasis. Primary and secondary safety endpoints were major and minor access site related vascular complications up to 30 days, respectively. Vascular complications were adjudicated by an independent clinical event committee according to VARC-2 criteria. We performed multivariable logistic regression to estimate the effect of baseline and procedural characteristics on any and major vascular complications. Results Between February 2018 and July 2019 500 patients were enrolled undergoing Transcatheter aortic valve replacement (TAVR, N = 496), Balloon aortic valvuloplasty (BAV, N = 2), Mechanical circulatory support (MCS, N = 1) or Endovascular aneurysm repair (EVAR, N = 1). Mean age was 80.8 +/- 6.6 years with a median STS-score of 2.7 [IQR 2.0-4.3] %. MANTA access site complications were major in 20 (4%) and minor in 28 patients (5.6%). Median time to hemostasis was 50 [IQR 20-120] sec. Severe femoral artery calcification, scar presence in groin, longer procedure duration, female gender and history of hypertension were independent predictors for vascular complications. Conclusion In this study, MANTA appeared to be a safe and effective device for large bore access closure under real-world conditions.Peer reviewe

    Standardized Definitions for Bioprosthetic Valve Dysfunction Following Aortic or Mitral Valve Replacement: JACC State-of-the-Art Review.

    Full text link
    peer reviewedBioprosthetic valve dysfunction (BVD) and bioprosthetic valve failure (BVF) may be caused by structural or nonstructural valve dysfunction. Both surgical and transcatheter bioprosthetic valves have limited durability because of structural valve deterioration. The main objective of this summary of experts participating in a virtual workshop was to propose standardized definitions for nonstructural and structural BVD and BVF following aortic or mitral biological valve replacement with the goal of facilitating research reporting and implementation of these terms in clinical practice. Definitions of structural BVF, based on valve reintervention or death, underestimate the true incidence of BVF. However, definitions solely based on the presence of high transprosthetic gradient at a given echocardiogram during follow-up overestimate the incidence of structural BVD and BVF. Definitions of aortic or mitral structural BVD must therefore include the confirmation by imaging of permanent structural changes to the leaflets alongside evidence of deterioration in valve hemodynamic function at echocardiography follow-up

    Same-Day Discharge Post–Transcatheter Aortic Valve Replacement During the COVID-19 Pandemic: The Multicenter PROTECT TAVR Study

    No full text
    Objectives: The aim of this study was to determine the safety and efficacy of same-day discharge (SDD) after transcatheter aortic valve replacement (TAVR) during the COVID-19 pandemic. Background: The COVID-19 pandemic has placed significant stress on health care systems worldwide. SDD in highly selected TAVR patients can facilitate the provision of essential cardiovascular care while managing competing COVID-19 resource demands. Methods: Patient selection for SDD was at the discretion of the local multidisciplinary heart team, across 7 international sites. The primary outcome was a composite of cardiovascular death, stroke, myocardial infarction, all-cause readmission, major vascular complications, and new permanent pacemaker (PPM) implantation. Results: From March 2020 to August 2021, 124 of 2,100 patients who underwent elective transfemoral TAVR were selected for SDD. The average age was 78.9 ± 7.8 years, the median Society of Thoracic Surgeons score was 2.4 (IQR: 1.4-4.2), and 32.3% (n = 40) had preexisting PPMs. There were no major vascular complications, strokes, or deaths during the index admission. One patient (0.8%) required PPM implantation for complete heart block and was discharged the same day. No patient required a PPM between discharge home and 30-day follow-up. The composite of cardiovascular death, stroke, myocardial infarction, all-cause readmission, major vascular complications, and new PPM at 30 days occurred in 5.7% patients (n = 6 of 106). Conclusions: SDD post-TAVR is safe and feasible in selected patients at low risk for adverse clinical events postdischarge. This strategy may have a potential role in highly selected patients even when the COVID-19 pandemic abates

    Reply

    No full text
    • …
    corecore