3,078 research outputs found

    Spray-dried Ni catalysts with tailored properties for CO2 methanation

    Get PDF
    A catalyst production method that enables the independent tailoring of the structural properties of the catalyst, such as pore size, metal particle size, metal loading or surface area, allows to increase the efficiency of a catalytic process. Such tailoring can help to make the valorization of CO2 into synthetic fuels on Ni catalysts competitive to conventional fossil fuel production. In this work, a new spray-drying method was used to produce Ni catalysts supported on SiO2 and Al2O3 nanoparticles with tunable properties. The influence of the primary particle size of the support, different metal loadings, and heat treatments were applied to investigate the potential to tailor the properties of catalysts. The catalysts were examined with physical and chemical characterization methods, including X-ray diffraction, temperature-programmed reduction, and chemisorption. A temperature-scanning technique was applied to screen the catalysts for CO2 methanation. With the spray-drying method presented here, well-organized porous spherical nanoparticles of highly dispersed NiO nanoparticles supported on silica with tunable properties were produced and characterized. Moreover, the pore size, metal particle size, and metal loading can be controlled independently, which allows to produce catalyst particles with the desired properties. Ni/SiO2 catalysts with surface areas of up to 40 m2 g−1 with Ni crystals in the range of 4 nm were produced, which exhibited a high activity for the CO2 methanation

    User involvement and desired service developments in drug treatment: Service user and provider views

    Get PDF
    Aims - To investigate the existing level of user involvement at selected agencies, to examine views about user involvement from both service-user and provider perspectives and to compare desired service developments. Design/Measurements - As part of a larger project, a series of semi-structured interviews was carried out between 2001 and 2003. Setting - Community-based drug services in Northern England. Participants - Service users (46) and service providers (51). Findings - Overall, the level of service-user involvement was low, with 16% of services having no user involvement at all. Nevertheless, service users expressed a desire for a high level of user involvement, compared with the low aspirations expressed by service providers. Service users' first priority for desired service developments was reduced waiting times, whereas service providers wished for increased provision of complementary therapies. Conclusions - The study highlighted important discrepancies regarding both desired level of user involvement and priorities for service developments between service users und providers. Given the current policies in this field and evidence that user involvement and closer partnerships between users and providers enhances treatment effectiveness, this lack of concurrence might be of major concern and working towards better understanding and balancing users' and providers' needs is highly recommended

    A liquid Xenon Positron Emission Tomograph for small animal imaging : first experimental results of a prototype cell

    Full text link
    A detector using liquid Xenon (LXe) in the scintillation mode is studied for Positron Emission Tomography (PET) of small animals. Its specific design aims at taking full advantage of the Liquid Xenon scintillation properties. This paper reports on energy, time and spatial resolution capabilities of the first LXe prototype module equipped with a Position Sensitive Photo- Multiplier tube (PSPMT) operating in the VUV range (178 nm) and at 165 K. The experimental results show that such a LXe PET configuration might be a promising solution insensitive to any parallax effect.Comment: 34 pages, 18 pages, to appear in NIM

    Dual-probe decoherence microscopy: Probing pockets of coherence in a decohering environment

    Get PDF
    We study the use of a pair of qubits as a decoherence probe of a non-trivial environment. This dual-probe configuration is modelled by three two-level-systems which are coupled in a chain in which the middle system represents an environmental two-level-system (TLS). This TLS resides within the environment of the qubits and therefore its coupling to perturbing fluctuations (i.e. its decoherence) is assumed much stronger than the decoherence acting on the probe qubits. We study the evolution of such a tripartite system including the appearance of a decoherence-free state (dark state) and non-Markovian behaviour. We find that all parameters of this TLS can be obtained from measurements of one of the probe qubits. Furthermore we show the advantages of two qubits in probing environments and the new dynamics imposed by a TLS which couples to two qubits at once.Comment: 29 pages, 10 figure

    Multichannel interference mitigation methods in radio astronomy

    Full text link
    Radio-astronomical observations are increasingly corrupted by RF interference, and online detection and filtering algorithms are becoming essential. To facilitate the introduction of such techniques into radio astronomy, we formulate the astronomical problem in an array signal processing language, and give an introduction to some elementary algorithms from that field. We consider two topics in detail: interference detection by rank estimation of short-term covariance matrices, and spatial filtering by subspace estimation and projection. We discuss experimental data collected at the Westerbork radio telescope, and illustrate the effectiveness of the space-time detection and blanking process on the recovery of a 3C48 absorption line in the presence of GSM mobile telephony interference.Comment: 39 pages, 18 figures.Enhanced figures can be downloaded from http://cas.et.tudelft.nl/~leshem/postscripts/leshem/figs34567.ps.gz To appear in Astrophysical Journal Supplements serie

    Blockchains for Business Process Management - Challenges and Opportunities

    Get PDF
    Blockchain technology promises a sizable potential for executing inter-organizational business processes without requiring a central party serving as a single point of trust (and failure). This paper analyzes its impact on business process management (BPM). We structure the discussion using two BPM frameworks, namely the six BPM core capabilities and the BPM lifecycle. This paper provides research directions for investigating the application of blockchain technology to BPM.Comment: Preprint for ACM TMI

    Two-dimensional electron gas at the (001) surface of ferromagnetic EuTiO3

    Get PDF
    Studies on oxide quasi-two-dimensional electron gas (q2DEG) have been a playground for the discovery of novel and sometimes unexpected phenomena, like the reported magnetism at the surface of SrTiO3 (001) and at the interface between nonmagnetic LaAlO3 and SrTiO3 band insulators. However, magnetism in this system is weak and there is evidence of a nonintrinsic origin. Here, by using in situ high-resolution angle-resolved photoemission, we demonstrate that ferromagnetic EuTiO3, the magnetic counterpart of SrTiO3 in the bulk, hosts a q2DEG at its (001) surface. This is confirmed by density functional theory calculations with Hubbard U terms in the presence of oxygen divacancies in various configurations, all of them leading to a spin-polarized q2DEG related to the ferromagnetic order of Eu-4f magnetic moments. The results suggest EuTiO3(001) as a new material platform for oxide q2DEGs, characterized by broken inversion and time-reversal symmetries

    Fluorescence characterization of clinically-important bacteria

    Get PDF
    Healthcare-associated infections (HCAI/HAI) represent a substantial threat to patient health during hospitalization and incur billions of dollars additional cost for subsequent treatment. One promising method for the detection of bacterial contamination in a clinical setting before an HAI outbreak occurs is to exploit native fluorescence of cellular molecules for a hand-held, rapid-sweep surveillance instrument. Previous studies have shown fluorescence-based detection to be sensitive and effective for food-borne and environmental microorganisms, and even to be able to distinguish between cell types, but this powerful technique has not yet been deployed on the macroscale for the primary surveillance of contamination in healthcare facilities to prevent HAI. Here we report experimental data for the specification and design of such a fluorescence-based detection instrument. We have characterized the complete fluorescence response of eleven clinically-relevant bacteria by generating excitation-emission matrices (EEMs) over broad wavelength ranges. Furthermore, a number of surfaces and items of equipment commonly present on a ward, and potentially responsible for pathogen transfer, have been analyzed for potential issues of background fluorescence masking the signal from contaminant bacteria. These include bedside handrails, nurse call button, blood pressure cuff and ward computer keyboard, as well as disinfectant cleaning products and microfiber cloth. All examined bacterial strains exhibited a distinctive double-peak fluorescence feature associated with tryptophan with no other cellular fluorophore detected. Thus, this fluorescence survey found that an emission peak of 340nm, from an excitation source at 280nm, was the cellular fluorescence signal to target for detection of bacterial contamination. The majority of materials analysed offer a spectral window through which bacterial contamination could indeed be detected. A few instances were found of potential problems of background fluorescence masking that of bacteria, but in the case of the microfiber cleaning cloth, imaging techniques could morphologically distinguish between stray strands and bacterial contamination

    A prospective cohort study assessing clinical referral management & workforce allocation within a UK regional medical genetics service

    Get PDF
    Abstract Ensuring patient access to genomic information in the face of increasing demand requires clinicians to develop innovative ways of working. This paper presents the first empirical prospective observational cohort study of UK multi-disciplinary genetic service delivery. It describes and explores collaborative working practices including the utilisation and role of clinical geneticists and non-medical genetic counsellors. Six hundred and fifty new patients referred to a regional genetics service were tracked through 850 clinical contacts until discharge. Referral decisions regarding allocation of lead health professional assigned to the case were monitored, including the use of initial clinical contact guidelines. Significant differences were found in the cases led by genetic counsellors and those led by clinical geneticists. Around a sixth, 16.8% (109/650) of referrals were dealt with by a letter back to the referrer or re-directed to another service provider and 14.8% (80/541) of the remaining patients chose not to schedule an appointment. Of the remaining 461 patients, genetic counsellors were allocated as lead health professional for 46.2% (213/461). A further 61 patients did not attend. Of those who did, 86% (345/400) were discharged after one or two appointments. Genetic counsellors contributed to 95% (784/825) of total patient contacts. They provided 93.7% (395/432) of initial contacts and 26.8% (106/395) of patients were discharged at that point. The information from this study informed a planned service re-design. More research is needed to assess the effectiveness and efficiency of different models of collaborative multi-disciplinary working within genetics services. Keywords (MeSH terms) Genetic Services, Genetic Counseling, Interdisciplinary Communication, Cohort Studies, Delivery of Healthcare, Referral and Consultation

    Comparing the performance of FA, DFA and DMA using different synthetic long-range correlated time series

    Get PDF
    Notwithstanding the significant efforts to develop estimators of long-range correlations (LRC) and to compare their performance, no clear consensus exists on what is the best method and under which conditions. In addition, synthetic tests suggest that the performance of LRC estimators varies when using different generators of LRC time series. Here, we compare the performances of four estimators [Fluctuation Analysis (FA), Detrended Fluctuation Analysis (DFA), Backward Detrending Moving Average (BDMA), and centred Detrending Moving Average (CDMA)]. We use three different generators [Fractional Gaussian Noises, and two ways of generating Fractional Brownian Motions]. We find that CDMA has the best performance and DFA is only slightly worse in some situations, while FA performs the worst. In addition, CDMA and DFA are less sensitive to the scaling range than FA. Hence, CDMA and DFA remain "The Methods of Choice" in determining the Hurst index of time series.Comment: 6 pages (including 3 figures) + 3 supplementary figure
    corecore