3,059 research outputs found

    Quantifying below-water fluvial geomorphic change: the implications of refraction correction, water surface elevations, and spatially variable error

    Get PDF
    Much of the geomorphic work of rivers occurs underwater. As a result, high resolutionquantification of geomorphic change in these submerged areas is important. Currently, to quantify thischange, multiple methods are required to get high resolution data for both the exposed and submergedareas. Remote sensing methods are often limited to the exposed areas due to the challenges imposedby the water, and those remote sensing methods for below the water surface require the collection ofextensive calibration data in-channel, which is time-consuming, labour-intensive, and sometimesprohibitive in dicult-to-access areas. Within this paper, we pioneer a novel approach for quantifyingabove- and below-water geomorphic change using Structure-from-Motion photogrammetry andinvestigate the implications of water surface elevations, refraction correction measures, and thespatial variability of topographic errors. We use two epochs of imagery from a site on the River Teme,Herefordshire, UK, collected using a remotely piloted aircraft system (RPAS) and processed usingStructure-from-Motion (SfM) photogrammetry. For the first time, we show that: (1) Quantification ofsubmerged geomorphic change to levels of accuracy commensurate with exposed areas is possiblewithout the need for calibration data or a dierent method from exposed areas; (2) there is minimaldierence in results produced by dierent refraction correction procedures using predominantlynadir imagery (small angle vs. multi-view), allowing users a choice of software packages/processingcomplexity; (3) improvements to our estimations of water surface elevations are critical for accuratetopographic estimation in submerged areas and can reduce mean elevation error by up to 73%;and (4) we can use machine learning, in the form of multiple linear regressions, and a Gaussian NaïveBayes classifier, based on the relationship between error and 11 independent variables, to generate ahigh resolution, spatially continuous model of geomorphic change in submerged areas, constrained byspatially variable error estimates. Our multiple regression model is capable of explaining up to 54%of magnitude and direction of topographic error, with accuracies of less than 0.04 m. With on-goingtesting and improvements, this machine learning approach has potential for routine application inspatially variable error estimation within the RPAS–SfM workflow

    Distribution patterns of HP1, a heterochromatin-associated nonhistone chromosomal protein of Drosophila

    Get PDF
    We have previously reported the identification of a nonhistone chromosomal protein (nhcp-19; now called HP1) preferentially associated with the heterochromatin of Drosophila melanogaster. A detailed study of the HP1 distribution pattern on polytene chromosomes by immunofluorescent staining, using monoclonal antibody C1A9, has been carried out. The results indicate that this protein is found within the centric beta-heterochromatin, in cytological regions 31, 41 and 80, and throughout polytene chromosome 4. Staining of telomeres is frequently observed, those of chromosome arms 2R and 3R and the X chromosome being the most conspicuous. Analysis of a fourth chromosome insertional translocation T(3;4)f/In(3L)P confirms an autonomous interaction with chromosome 4 material. Similarly, the beta-heterochromatin distal to light on chromosome arm 2L, moved to position 97D2 on chromosome arm 3R in the rearrangement ltx13, is prominently stained using the C1A9 antibody. Staining of intact salivary glands indicates that this rearranged segment of beta-heterochromatin is not associated with the polytene chromocenter, but provides an independent structural reference point. HP1 is not observed in the nuclei of the early syncytial embryo, but becomes concentrated in the nuclei at the syncytial blastoderm stage (ca. nuclear division cycle 10). This suggests that heterochromatin formation occurs at approximately the same stage at which nuclei first become transcriptionally competent. Thus, the C1A9 antibody may serve as a useful marker for both structural and functional studies of the Drosophila nucleus

    Double-Peaked Low-Ionization Emission Lines in Active Galactic Nuclei

    Full text link
    We present a new sample of 116 double-peaked Balmer line Active Galactic Nuclei (AGN) selected from the Sloan Digital Sky Survey. Double-peaked emission lines are believed to originate in the accretion disks of AGN, a few hundred gravitational radii (Rg) from the supermassive black hole. We investigate the properties of the candidate disk emitters with respect to the full sample of AGN over the same redshifts, focusing on optical, radio and X-ray flux, broad line shapes and narrow line equivalent widths and line flux-ratios. We find that the disk-emitters have medium luminosities (~10^44erg/s) and FWHM on average six times broader than the AGN in the parent sample. The double-peaked AGN are 1.6 times more likely to be radio-sources and are predominantly (76%) radio quiet, with about 12% of the objects classified as LINERs. Statistical comparison of the observed double-peaked line profiles with those produced by axisymmetric and non-axisymmetric accretion disk models allows us to impose constraints on accretion disk parameters. The observed Halpha line profiles are consistent with accretion disks with inclinations smaller than 50 deg, surface emissivity slopes of 1.0-2.5, outer radii larger than ~2000 Rg, inner radii between 200-800Rg, and local turbulent broadening of 780-1800 km/s. The comparison suggests that 60% of accretion disks require some form of asymmetry (e.g., elliptical disks, warps, spiral shocks or hot spots).Comment: 60 pages, 19 figures, accepted for publication in AJ. For high quality figures and full tables, please see http://astro.princeton.edu/~iskra/disks.htm

    Holography of a Composite Inflaton

    Full text link
    We study the time evolution of a brane construction that is holographically dual to a strongly coupled gauge theory that dynamically breaks a global symmetry through the generation of an effective composite Higgs vev. The D3/D7 system with a background magnetic field or non-trivial gauge coupling (dilaton) profile displays the symmetry breaking. We study motion of the D7 brane in the background of the D3 branes. For small field inflation in the field theory the effective Higgs vev rolls from zero to the true vacuum value. We study what phenomenological dilaton profile generates the slow rolling needed, hence learning how the strongly coupled gauge theory's coupling must run. We note that evolution of our configuration in the holographic direction, representing the phyiscs of the strong interactions, can provide additional slowing of the roll time. Inflation seems to be favoured if the coupling changes by only a small amount or very gently. We speculate on how such a scenario could be realized away from N=4 gauge theory, for example, in a walking gauge theory.Comment: 13 pages, 12 figures; v2: Added reference

    Submucosal diclofenac for acute postoperative pain in third molar surgery: A randomized, controlled clinical trial

    Get PDF
    Diclofenac sodium is a widely used nonsteroidal anti-inflammatory drug (NSAID) for relief of inflammatory pain. A recent formulation combines this drug with hydroxypropyl-β-cyclodextrin (HPβCD) to improve its solubility and to enable subcutaneous administration. Previous studies confirmed the efficacy of this combination. This study’s aim was to evaluate the efficacy, safety, and local tolerability of diclofenac HPβCD administered as a local submucosal injection prior to lower third molar surgery. We conducted a prospective, randomized, double-blind, placebo-controlled, parallel-group phase II single-center study. Seventy-five patients requiring mandibular third molar surgery were randomized into 1 of 5 groups: 5 mg/1 mL diclofenac HPβCD, 12.5 mg/1 mL diclofenac HPβCD, 25 mg/1 mL diclofenac HPβCD, 50 mg/1 mL diclofenac HPβCD, or 1 mL placebo. The respective study drug was injected into the mucosal tissue surrounding the surgical site prior to surgery following achievement of local anesthesia. The primary outcome measure was the area under the curve (AUC) of cumulative pain scores from end of surgery to 6 h postsurgery. This demonstrated a global treatment effect between the active groups and placebo, hence confirming the study drug’s efficacy (P = 0.0126). Secondary outcome measures included the time until onset of pain and the time until patients required rescue medication, both showing statistical significance of the study drug compared to placebo (P < 0.0161 and P < 0.0001, respectively). The time until rescue medication ranged between 7.8 h (for 25 mg/1 mL diclofenac HPβCD) and 16 h (for 50 mg/1 mL diclofenac HPβCD). Interestingly, the 5-mg/1-mL solution appeared superior to the 12.5-mg/1-mL and 25-mg/1-mL solutions (time until rescue medication = 12.44 h). A total of 14% of patients experienced minor adverse drug reactions (ADRs), of which 2 cases demonstrated flap necrosis. These resolved without further intervention. The study results overall indicate efficacy, safety, and relative tolerability of diclofenac HPβCD used locally as a submucosal injection prior to third molar surgery (ClinicalTrials.gov NCT01706588)
    • …
    corecore