6,887 research outputs found

    Climatic impacts of stratospheric geoengineering with sulfate, black carbon and titania injection

    Get PDF
    In this paper, we examine the potential climatic effects of geoengineering by sulfate, black carbon and titania injection against a baseline RCP8.5 scenario. We use the HadGEM2-CCS model to simulate scenarios in which the top-of-the-atmosphere radiative imbalance due to rising greenhouse gas concentrations is offset by sufficient aerosol injection throughout the 2020–2100 period. We find that the global-mean temperature is effectively maintained at historical levels for the entirety of the period for all 3 aerosol-injection scenarios, though there are a wide range of side-effects which are discussed in detail. The most prominent conclusion is that although the BC injection rate necessary to produce an equivalent global mean temperature-response is much lower, the severity of stratospheric temperature changes (> +70 °C) and precipitation impacts effectively exclude BC from being a viable option for geoengineering. Additionally, while it has been suggested that titania would be an effective particle because of its high scattering efficiency, it also efficiently absorbs solar ultraviolet radiation producing a significant stratospheric warming (> +20 °C). As injection rates for titania are close to those for sulfate, there appears little benefit of using titania when compared to injection of sulfur dioxide, which has the added benefit of being well modelled through extensive research that has been carried out on naturally occurring explosive volcanic eruptions.The authors would like to thank Valentina Aquila for supplying AVHRR and SAGE data, and to Peter Cox, Angus Ferraro, David Keith and Alan Robock for helpful discussions. A. C. Jones was supported by a Met Office/NERC CASE (ref. 580 009 183) PhD studentship; J. M. Haywood and A. Jones were supported by the Joint UK DECC/Defra Met Office Hadley Centre Climate Programme (GA01101)

    The role of ECL2 in CGRP receptor activation: a combined modelling and experimental approach

    Get PDF
    The calcitonin gene-related peptide (CGRP) receptor is a complex of a calcitonin receptor-like receptor (CLR), which is a family B G-protein-coupled receptor (GPCR) and receptor activity modifying protein 1. The role of the second extracellular loop (ECL2) of CLR in binding CGRP and coupling to Gs was investigated using a combination of mutagenesis and modelling. An alanine scan of residues 271–294 of CLR showed that the ability of CGRP to produce cAMP was impaired by point mutations at 13 residues; most of these also impaired the response to adrenomedullin (AM). These data were used to select probable ECL2-modelled conformations that are involved in agonist binding, allowing the identification of the likely contacts between the peptide and receptor. The implications of the most likely structures for receptor activation are discussed.</jats:p

    Microalbuminuria could improve risk stratification in patients with TIA and minor stroke.

    Get PDF
    Published onlineJournal ArticleThis is the final version of the article. Available from Wiley Open Access via the DOI in this record.OBJECTIVE: Transient ischemic attacks (TIA) and minor strokes are important risk factors for recurrent strokes. Current stroke risk prediction scores such as ABCD2, although widely used, lack optimal sensitivity and specificity. Elevated urinary albumin excretion predicts cardiovascular disease, stroke, and mortality. We explored the role of microalbuminuria (using albumin creatinine ratio (ACR)) in predicting recurrence risk in patients with TIA and minor stroke. METHODS: Urinary ACR was measured on a spot sample in 150 patients attending a daily stroke clinic with TIA or minor stroke. Patients were followed up at day 7, 30, and 90 to determine recurrent stroke, cardiovascular events, or death. Eligible patients had a carotid ultrasound Doppler investigation. High-risk patients were defined as those who had an event within 90 days or had >50% internal carotid artery (ICA) stenosis. RESULTS: Fourteen (9.8%) recurrent events were reported by day 90 including two deaths. Fifteen patients had severe ICA stenosis. In total, 26 patients were identified as high risk. These patients had a higher frequency of previous stroke or hypercholesterolemia compared to low-risk patients (P = 0.04). ACR was higher in high-risk patients (3.4 [95% CI 2.2-5.2] vs. 1.7 [1.5-2.1] mg/mmol, P = 0.004), independent of age, sex, blood pressure, diabetes, and previous stroke. An ACR greater than 1.5 mg/mmol predicted high-risk patients (Cox proportional hazard ratio 3.5 (95% CI 1.3-9.5, P = 0.01). INTERPRETATION: After TIA or minor stroke, a higher ACR predicted recurrent events and significant ICA stenosis. Incorporation of urinary ACR from a spot sample in the acute setting could improve risk stratification in patients with TIA and minor stroke.This article presents independent research supported by the NIHR Exeter Clinical Research Facility and the NIHR Collaboration for Leadership in Applied Health Research and Care (CLAHRC) for the South West Peninsula. The views expressed in this publication are those of the author(s) and not necessarily those of the NIHR Exeter Clinical Research Facility, the NHS, the NIHR or the Department of Health in England. We also acknowledge and thank the South West Stroke Research Network for their help with patient recruitment and follow-up, and Mrs. Audrey Peters and Mr. Frank Summers for performing the carotid Doppler scans

    Ferritin and Iron Studies in Anaemia and Chronic Disease

    Get PDF
    Anaemia is a condition in which the number of red cells necessary to meet the body's physiological requirements is insufficient. Iron deficiency anaemia (IDA) and the anaemia of chronic disease (ACD) are the two most common causes of anaemia worldwide; iron homeostasis plays a pivotal role in the pathogenesis of both diseases. An understanding of how iron studies can be used to distinguish between these diseases is therefore essential, not only for diagnosis but also in guiding management. This review will primarily focus on IDA and ACD; however iron overload in anaemia will also be briefly discussed

    The secret world of shrimps: polarisation vision at its best

    Get PDF
    Animal vision spans a great range of complexity, with systems evolving to detect variations in optical intensity, distribution, colour, and polarisation. Polarisation vision systems studied to date detect one to four channels of linear polarisation, combining them in opponent pairs to provide intensity-independent operation. Circular polarisation vision has never been seen, and is widely believed to play no part in animal vision. Polarisation is fully measured via Stokes' parameters--obtained by combined linear and circular polarisation measurements. Optimal polarisation vision is the ability to see Stokes' parameters: here we show that the crustacean \emph{Gonodactylus smithii} measures the exact components required. This vision provides optimal contrast-enhancement, and precise determination of polarisation with no confusion-states or neutral-points--significant advantages. We emphasise that linear and circular polarisation vision are not different modalities--both are necessary for optimal polarisation vision, regardless of the presence of strongly linear or circularly polarised features in the animal's environment.Comment: 10 pages, 6 figures, 2 table

    Performance of Monolayer Graphene Nanomechanical Resonators with Electrical Readout

    Full text link
    The enormous stiffness and low density of graphene make it an ideal material for nanoelectromechanical (NEMS) applications. We demonstrate fabrication and electrical readout of monolayer graphene resonators, and test their response to changes in mass and temperature. The devices show resonances in the MHz range. The strong dependence of the resonant frequency on applied gate voltage can be fit to a membrane model, which yields the mass density and built-in strain. Upon removal and addition of mass, we observe changes in both the density and the strain, indicating that adsorbates impart tension to the graphene. Upon cooling, the frequency increases; the shift rate can be used to measure the unusual negative thermal expansion coefficient of graphene. The quality factor increases with decreasing temperature, reaching ~10,000 at 5 K. By establishing many of the basic attributes of monolayer graphene resonators, these studies lay the groundwork for applications, including high-sensitivity mass detectors

    Symptoms associated with victimization in patients with schizophrenia and related disorders

    Get PDF
    Background: Patients with psychoses have an increased risk of becoming victims of violence. Previous studies have suggested that higher symptom levels are associated with a raised risk of becoming a victim of physical violence. There has been, however, no evidence on the type of symptoms that are linked with an increased risk of recent victimization. Methods: Data was taken from two studies on involuntarily admitted patients, one national study in England and an international one in six other European countries. In the week following admission, trained interviewers asked patients whether they had been victims of physical violence in the year prior to admission, and assessed symptoms on the Brief Psychiatric Rating Scale (BPRS). Only patients with a diagnosis of schizophrenia or related disorders (ICD-10 F20–29) were included in the analysis which was conducted separately for the two samples. Symptom levels assessed on the BPRS subscales were tested as predictors of victimization. Univariable and multivariable logistic regression models were fitted to estimate adjusted odds ratios. Results: Data from 383 patients in the English sample and 543 patients in the European sample was analysed. Rates of victimization were 37.8% and 28.0% respectively. In multivariable models, the BPRS manic subscale was significantly associated with victimization in both samples. Conclusions: Higher levels of manic symptoms indicate a raised risk of being a victim of violence in involuntary patients with schizophrenia and related disorders. This might be explained by higher activity levels, impaired judgement or poorer self-control in patients with manic symptoms. Such symptoms should be specifically considered in risk assessments

    Global parameter search reveals design principles of the mammalian circadian clock

    Get PDF
    Background: Virtually all living organisms have evolved a circadian (~24 hour) clock that controls physiological and behavioural processes with exquisite precision throughout the day/night cycle. The suprachiasmatic nucleus (SCN), which generates these ~24 h rhythms in mammals, consists of several thousand neurons. Each neuron contains a gene-regulatory network generating molecular oscillations, and the individual neuron oscillations are synchronised by intercellular coupling, presumably via neurotransmitters. Although this basic mechanism is currently accepted and has been recapitulated in mathematical models, several fundamental questions about the design principles of the SCN remain little understood. For example, a remarkable property of the SCN is that the phase of the SCN rhythm resets rapidly after a 'jet lag' type experiment, i.e. when the light/ dark (LD) cycle is abruptly advanced or delayed by several hours. Results: Here, we describe an extensive parameter optimization of a previously constructed simplified model of the SCN in order to further understand its design principles. By examining the top 50 solutions from the parameter optimization, we show that the neurotransmitters' role in generating the molecular circadian rhythms is extremely important. In addition, we show that when a neurotransmitter drives the rhythm of a system of coupled damped oscillators, it exhibits very robust synchronization and is much more easily entrained to light/dark cycles. We were also able to recreate in our simulations the fast rhythm resetting seen after a 'jet lag' type experiment. Conclusion: Our work shows that a careful exploration of parameter space for even an extremely simplified model of the mammalian clock can reveal unexpected behaviours and non-trivial predictions. Our results suggest that the neurotransmitter feedback loop plays a crucial role in the robustness and phase resetting properties of the mammalian clock, even at the single neuron level

    Accuracy of magnetic resonance studies in the detection of chondral and labral lesions in femoroacetabular impingement : systematic review and meta-analysis

    Get PDF
    Background: Several types of Magnetic resonance imaging (MRI) are commonly used in imaging of femoroacetabular impingement (FAI), however till now there are no clear protocols and recommendations for each type. The aim of this meta-analysis is to detect the accuracy of conventional magnetic resonance imaging (cMRI), direct magnetic resonance arthrography (dMRA) and indirect magnetic resonance arthrography (iMRA) in the diagnosis of chondral and labral lesions in femoroacetabular impingement (FAI). Methods: A literature search was finalized on the 17th of May 2016 to collect all studies identifying the accuracy of cMRI, dMRA and iMRA in diagnosing chondral and labral lesions associated with FAI using surgical results (arthroscopic or open) as a reference test. Pooled sensitivity and specificity with 95% confidence intervals using a random-effects meta-analysis for MRI, dMRA and iMRA were calculated also area under receiver operating characteristic (ROC) curve (AUC) was retrieved whenever possible where AUC is equivocal to diagnostic accuracy. Results: The search yielded 192 publications which were reviewed according inclusion and exclusion criteria then 21 studies fulfilled the eligibility criteria for the qualitative analysis with a total number of 828 cases, lastly 12 studies were included in the quantitative meta-analysis. Meta-analysis showed that as regard labral lesions the pooled sensitivity, specificity and AUC for cMRI were 0.864, 0.833 and 0.88 and for dMRA were 0.91, 0.58 and 0.92. While in chondral lesions the pooled sensitivity, specificity and AUC for cMRI were 0.76, 0.72 and 0.75 and for dMRA were 0.75, 0.79 and 0.83, while for iMRA were sensitivity of 0.722 and specificity of 0.917. Conclusions: The present meta-analysis showed that the diagnostic test accuracy was superior for dMRA when compared with cMRI for detection of labral and chondral lesions. The diagnostic test accuracy was superior for labral lesions when compared with chondral lesions in both cMRI and dMRA. Promising results are obtained concerning iMRA but further studies still needed to fully assess its diagnostic accuracy
    corecore