4 research outputs found

    The Impact of Supply Chain Capabilities on Logistic Efficiency for the Construction Projects

    Get PDF
    Rapid technological advancements force organizations to be more proactive and efficient it operations while previous studies revealed that most of the public sector projects go over in term of time and cost. Although extensive literature is available but only for the private sector, the investigations on the public sector are scarce. After plentiful literature, it has found that timely and sage supply chain is a major hurdle. Various strategies and approaches have been proposed to tackle the situation but after a thorough investigation, it was found that flexibility and collaboration are the topmost influencing factors in improving logistic efficiency. Thus the aim of this study is to empirically verify the positive impact of flexibility and collaboration on logistic efficiency. A questionnaire was adopted and distributed by random sampling to the strategic level of the construction projects in the city of Lahore, Pakistan. Multiple regressions were applied through SPSS. The finding of the study revealed that flexibility contributes 33%, collaboration contributes 35.5% in the logistic efficiency. It can be concluded that construction projects must be flexible and force stakeholders for collaboration. This study added in the frame of knowledge as new findings for public sector projects. This study will help the managers in completing their projects timely and accurately

    INVESTIGATION OF GEOTHERMAL ENERGY POTENTIAL USING ELECTRICAL RESISTIVITY SURVEY AND CHEMICAL GEOTHERMOMETERS: A STUDY OF THE MANGHOPIR HOT SPRING KARACHI, SINDH PAKISTAN

    Get PDF
    Electrical resistivity survey and chemical geothermometers methods were used to find the geothermal gradient energy potential of the Manghopir hot spring which is located in Karachi, Sindh. Schlumberger electrode configurations were used to demarcate the two shallow potential subsurface aquifers. At various depths, three lithological units were encountered: alluvium, sandstone, and shale. The first thermal water aquifer lies below at the average depth of 10m and average thickness of 9 m lies in sandstone lithology of Nari Formation of Oligocene age. The second thermal water aquifer encountered at the average depth of 68 m and the average thickness of aquifer was 40.5m in sandstone lithology of Nari Formation. The surface water temperature was calculated with digital thermometer which shows the range in between 48 °C to 50 °C and subsurface temperature was calculated with the help of chemical geothermometers. The Na–K geothermometers indicate the subsurface equilibrium reservoir temperature in the range of 135.52 °C,125.54 °C, 172.964 °C and 184.08°C and the Na-K-Ca chemical geothermometers indicate the subsurface reservoir temperature 148.493°C. The Na-K-Ca geothermometers show a high temperature, but the reservoir temperature appears to be lower due to the mixing of sea water with the chemical composition of hot spring water within the subsurface aquifers

    Exploration of Shallow Geothermal Energy Aquifers by Using Electrical Resistivity Survey in Laki Range Jamshoro district Sindh, Pakistan

    Get PDF
    Geothermal water is increasingly used around the world for its exploitation. Bulk electrical resistivity differences can bring significant information on variation of subsurface geothermal aquifer characteristics. The electrical resistivity survey was carried out in Laki range in lower Indus basin in the study area to explore the subsurface geothermal aquifers. The Schlumberger electrode configuration with range from 2 m to 220 m depth was applied. Three prominent locations of hot springs were selected including Laki Shah Saddar, Lalbagh and Kai hot spring near Sehwan city. After processing resistivity image data, two hot water geothermal aquifers were delineated at Laki Shah Sadder hot springs. The depth of first aquifer was 56 m and its thickness 38 m in the limestones. The depth of second aquifer of 190 m and with thickness of 96 m hosted in limestone. In Lalbagh hot springs two geothermal aquifers were delineated on the basis of apparent resistivity contrast, the depth of first aquifer zone in sandstone was in sandstone 15 m and thickness 12 m, while the depth of second aquifer was 61m and thickness was 35m. In Kai hot springs two hot water geothermal aquifers were delineated. The depth of first geothermal aquifer was 21m and thickness was 18 m and the depth of second aquifer was 105 m and thickness was 61m present in sandstone lithology. Present work demonstrates the capability of electrical resistivity images to study the potential of geothermal energy in shallow aquifers. These outcomes could potentially lead to a number of practical applications, such as the monitoring or the design of shallow geothermal systems

    Evaluation of a quality improvement intervention to reduce anastomotic leak following right colectomy (EAGLE): pragmatic, batched stepped-wedge, cluster-randomized trial in 64 countries

    Get PDF
    Background Anastomotic leak affects 8 per cent of patients after right colectomy with a 10-fold increased risk of postoperative death. The EAGLE study aimed to develop and test whether an international, standardized quality improvement intervention could reduce anastomotic leaks. Methods The internationally intended protocol, iteratively co-developed by a multistage Delphi process, comprised an online educational module introducing risk stratification, an intraoperative checklist, and harmonized surgical techniques. Clusters (hospital teams) were randomized to one of three arms with varied sequences of intervention/data collection by a derived stepped-wedge batch design (at least 18 hospital teams per batch). Patients were blinded to the study allocation. Low- and middle-income country enrolment was encouraged. The primary outcome (assessed by intention to treat) was anastomotic leak rate, and subgroup analyses by module completion (at least 80 per cent of surgeons, high engagement; less than 50 per cent, low engagement) were preplanned. Results A total 355 hospital teams registered, with 332 from 64 countries (39.2 per cent low and middle income) included in the final analysis. The online modules were completed by half of the surgeons (2143 of 4411). The primary analysis included 3039 of the 3268 patients recruited (206 patients had no anastomosis and 23 were lost to follow-up), with anastomotic leaks arising before and after the intervention in 10.1 and 9.6 per cent respectively (adjusted OR 0.87, 95 per cent c.i. 0.59 to 1.30; P = 0.498). The proportion of surgeons completing the educational modules was an influence: the leak rate decreased from 12.2 per cent (61 of 500) before intervention to 5.1 per cent (24 of 473) after intervention in high-engagement centres (adjusted OR 0.36, 0.20 to 0.64; P < 0.001), but this was not observed in low-engagement hospitals (8.3 per cent (59 of 714) and 13.8 per cent (61 of 443) respectively; adjusted OR 2.09, 1.31 to 3.31). Conclusion Completion of globally available digital training by engaged teams can alter anastomotic leak rates. Registration number: NCT04270721 (http://www.clinicaltrials.gov)
    corecore