25 research outputs found

    Non-commutative multi-dimensional cosmology

    Full text link
    A non-commutative multi-dimensional cosmological model is introduced and used to address the issues of compactification and stabilization of extra dimensions and the cosmological constant problem. We show that in such a scenario these problems find natural solutions in a universe described by an increasing time parameter.Comment: 9 pages, 1 figure, to appear in JHE

    The shadows of quantum gravity on Bell's inequality

    Get PDF
    This study delves into the validity of quantum mechanical operators in the context of quantum gravity, recognizing the potential need for their generalization. A primary objective is to investigate the repercussions of these generalizations on the inherent non-locality within quantum mechanics, as exemplified by Bell's inequality. Additionally, the study scrutinizes the consequences of introducing a non-zero minimal length into the established framework of Bell's inequality. The findings contribute significantly to our theoretical comprehension of the intricate interplay between quantum mechanics and gravity. Moreover, this research explores the impact of quantum gravity on Bell's inequality and its practical applications within quantum technologies, notably in the realms of device-independent protocols, quantum key distribution, and quantum randomness generation

    Multi-dimensional classical and quantum cosmology: Exact solutions, signature transition and stabilization

    Full text link
    We study the classical and quantum cosmology of a (4+d)(4+d)-dimensional spacetime minimally coupled to a scalar field and present exact solutions for the resulting field equations for the case where the universe is spatially flat. These solutions exhibit signature transition from a Euclidean to a Lorentzian domain and lead to stabilization of the internal space, in contrast to the solutions which do not undergo signature transition. The corresponding quantum cosmology is described by the Wheeler-DeWitt equation which has exact solutions in the mini-superspace, resulting in wavefunctions peaking around the classical paths. Such solutions admit parametrizations corresponding to metric solutions of the field equations that admit signature transition.Comment: 15 pages, two figures, to appear in JHE

    Long-term clinical outcomes of losartan in patients with Marfan syndrome:follow-up of the multicentre randomized controlled COMPARE trial

    Get PDF
    AIMS: The COMPARE trial showed a small but significant beneficial effect of 3-year losartan treatment on aortic root dilatation rate in adults with Marfan syndrome (MFS). However, no significant effect was found on clinical endpoints, possibly due to a short follow-up period. The aim of the current study was therefore to investigate the long-term clinical outcomes after losartan treatment. METHODS AND RESULTS: In the original COMPARE study (inclusion 2008-2009), adult patients with MFS (n = 233) were randomly allocated to either the angiotensin-II receptor blocker losartan® on top of regular treatment (β-blockers in 71% of the patients) or no additional medication. After the COMPARE trial period of 3 years, study subjects chose to continue their losartan medication or not. In a median follow-up period of 8 years, 75 patients continued losartan medication, whereas 78 patients, originally allocated to the control group, never used losartan after inclusion. No differences existed between baseline characteristics of the two groups except for age at inclusion [losartan 34 (interquartile range, IQR 26-43) years, control 41 (IQR 30-52) years; P = 0.031], and β-blocker use (losartan 81%, control 64%; P = 0.022). A pathological FBN1 mutation was present in 76% of patients and 58% of the patients were male. Clinical endpoints, defined as all-cause mortality, aortic dissection/rupture, elective aortic root replacement, reoperation, and vascular graft implantation beyond the aortic root, were compared between the two groups. A per-patient composite endpoint was also analysed. Five deaths, 14 aortic dissections, 23 aortic root replacements, 3 reoperations, and 3 vascular graft implantations beyond the aortic root occurred during follow-up. Except for aortic root replacement, all endpoints occurred in patients with an operated aortic root. Patients who used losartan during the entire follow-up period showed a reduced number of events compared to the control group (death: 0 vs. 5, P = 0.014; aortic dissection: 3 vs. 11, P = 0.013; elective aortic root replacement: 10 vs. 13, P = 0.264; reoperation: 1 vs. 2, P = 0.463; vascular graft implantations beyond the aortic root 0 vs. 3, P = 0.071; and composite endpoint: 14 vs. 26, P = 0.019). These results remained similar when corrected for age and β-blocker use in a multivariate analysis. CONCLUSION: These results suggest a clinical benefit of combined losartan and β-blocker treatment in patients with MFS

    Robotic Ultrasound Guidance by B-scan Plane Positioning Control

    Get PDF
    AbstractUltrasound is indispensable imaging modality for clinical diagnosis such as fetus assessment and heart assessment. Moreover, many ultrasound applications for image guided procedures have been proposed and attempted because US is less invasive, less cost, and high portability. However, to obtain US images, a US imaging probe has to be held manually and contacted with a patient body. To address the issue, we have proposed a robotic system for automatic probe scanning. The system consists of a probe scanning robot, navigation software, an optical tracking device, and an ultrasound imaging device. The robot, that is six degrees of freedom, is composed of a frame mechanism and a probe holding mechanism. The frame mechanism has six pneumatic actuators to reduce its weight, and the probe holding mechanism has one DC motor. The probe holding mechanism is connected with the pneumatic actuators using wires. Moreover, the robot can control the position and orientation of the B-scan plane based on the transformation between an optical tracker attached to the US probe and the B-scan plane. The navigation system, which is connected with the tracking device and an US imaging device via a VGA cable, computes the relative position between the positions of a therapeutic tool and the B-scan plane, and sends it to the robot. Then the position of the B-scan plane can be controlled based on the tool position. Also, the navigation system displays the plane with a texture of an actual echogram and a tool model three-dimensionally to monitor the relative position of the tool and the B-scan plane. To validate the basic system performance, phantom tests were conducted. The phantom was made of gelatin and poly(ethylene glycol). In the tests, the needle was inserted into the phantom, and the B-scan plane was controlled to contain a tracked needle in real-time. From the results, the needle was continuously visualized during needle insertion. Therefore, it is confirmed that the system has a great potential for automatic US image guided procedures

    Editor's Choice - Nationwide Analysis of Patients Undergoing Iliac Artery Aneurysm Repair in the Netherlands

    No full text
    OBJECTIVE: The new 2019 guideline of the European Society for Vascular Surgery (ESVS) recommends consideration for elective iliac artery aneurysm (eIAA) repair when the iliac diameter exceeds 3.5 cm, as opposed to 3.0 cm previously. The current study assessed diameters at time of eIAA repair and ruptured IAA (rIAA) repair and compared clinical outcomes after open surgical repair (OSR) and endovascular aneurysm repair (EVAR).METHODS: This retrospective observational study used the nationwide Dutch Surgical Aneurysm Audit (DSAA) registry that includes all patients who undergo aorto-iliac aneurysm repair in the Netherlands. All patients who underwent primary IAA repair between 1 January 2014 and 1 January 2018 were included. Diameters at time of eIAA and rIAA repair were compared in a descriptive fashion. The anatomical location of the IAA was not registered in the registry. Patient characteristics and outcomes of OSR and EVAR were compared with appropriate statistical tests.RESULTS: The DSAA registry comprised 974 patients who underwent IAA repair. A total of 851 patients were included after exclusion of patients undergoing revision surgery and patients with missing essential variables. eIAA repair was carried out in 713 patients, rIAA repair in 102, and symptomatic IAA repair in 36. OSR was performed in 205, EVAR in 618, and hybrid repairs and conversions in 28. The median maximum IAA diameter at the time of eIAA and rIAA repair was 43 (IQR 38-50) mm and 68 (IQR 58-85) mm, respectively. Mortality was 1.3% (95% CI 0.7-2.4) after eIAA repair and 25.5% (95% CI 18.0-34.7) after rIAA repair. Mortality was not significantly different between the OSR and EVAR subgroups. Elective OSR was associated with significantly more complications than EVAR (intra-operative: 9.8% vs. 3.6%, post-operative: 34.0% vs. 13.8%, respectively).CONCLUSION: In the Netherlands, most eIAA repairs are performed at diameters larger than recommended by the ESVS guideline. These findings appear to support the recent increase in the threshold diameter for eIAA repair.</p

    Editor's Choice - Nationwide Analysis of Patients Undergoing Iliac Artery Aneurysm Repair in the Netherlands

    No full text
    OBJECTIVE: The new 2019 guideline of the European Society for Vascular Surgery (ESVS) recommends consideration for elective iliac artery aneurysm (eIAA) repair when the iliac diameter exceeds 3.5 cm, as opposed to 3.0 cm previously. The current study assessed diameters at time of eIAA repair and ruptured IAA (rIAA) repair and compared clinical outcomes after open surgical repair (OSR) and endovascular aneurysm repair (EVAR). METHODS: This retrospective observational study used the nationwide Dutch Surgical Aneurysm Audit (DSAA) registry that includes all patients who undergo aorto-iliac aneurysm repair in the Netherlands. All patients who underwent primary IAA repair between 1 January 2014 and 1 January 2018 were included. Diameters at time of eIAA and rIAA repair were compared in a descriptive fashion. The anatomical location of the IAA was not registered in the registry. Patient characteristics and outcomes of OSR and EVAR were compared with appropriate statistical tests. RESULTS: The DSAA registry comprised 974 patients who underwent IAA repair. A total of 851 patients were included after exclusion of patients undergoing revision surgery and patients with missing essential variables. eIAA repair was carried out in 713 patients, rIAA repair in 102, and symptomatic IAA repair in 36. OSR was performed in 205, EVAR in 618, and hybrid repairs and conversions in 28. The median maximum IAA diameter at the time of eIAA and rIAA repair was 43 (IQR 38-50) mm and 68 (IQR 58-85) mm, respectively. Mortality was 1.3% (95% CI 0.7-2.4) after eIAA repair and 25.5% (95% CI 18.0-34.7) after rIAA repair. Mortality was not significantly different between the OSR and EVAR subgroups. Elective OSR was associated with significantly more complications than EVAR (intra-operative: 9.8% vs. 3.6%, post-operative: 34.0% vs. 13.8%, respectively). CONCLUSION: In the Netherlands, most eIAA repairs are performed at diameters larger than recommended by the ESVS guideline. These findings appear to support the recent increase in the threshold diameter for eIAA repair

    Quality management of Zarrineh Rud river for agricultural irrigation using QUAL2K simulation model

    No full text
    Zarrineh Rud river is one of the most important rivers in northwest of Iran. In this study, QUAL2K simulation model was used. The simulation parameters in this study were collected from 5 sampling stations. The results showed that the amount of oxygen saturated solution of Zarrineh Rud river varied between 7–8 mg / l, which is higher than the maximum standard value required. The results showed that BOD could increase by 16%, respectively, and should decrease by 70%. The station S5 at the river downstream with 3.53 mg/L DO deficit was the most critical point, and the 26th kilometer of the river with a DO deficit of 2.05 mg/L was the most critical point for maintaining the aquatic life; therefore, some scenario must be developed for waste load reduction at this station. In order to improve the quality of Zarrineh Rud river, construction of a wastewater treatment plant is necessary for Miandoab sugar factory

    Incidence and etiology of mortality in polytrauma patients in a Dutch level I trauma center

    No full text
    Background Earlier studies assessing mortality in polytrauma patients have focused on improving trauma care and reducing complications during hospital stay. The same studies have shown that the complication rate in these patients is high, often resulting in death. The aim of this study was to assess the incidence and causes of mortality in polytrauma patients in our institute. Secondarily, we assessed the donation and autopsy rates and outcome in these patients. Patients and methods All polytrauma patients (injury severity score≥16) transported to and treated in our institute during a period of 6 years were retrospectively analyzed. We included all patients who died during hospital stay. Prehospital and in-hospital data were collected on patients' condition, diagnostics, and treatment. The chance of survival was calculated according to the TRISS methodology. Patients were categorized according to the complications during treatment and causes of death. Logistic regression analysis was used to design a prediction model for mortality in major trauma. A statistical analysis was carried out. Results Of the 1073 polytrauma patients who were treated in our institute during the study period, 205 (19.1%) died during hospital stay. The median age of the deceased patients was 58.8 years and 125 patients were men. Their mean injury severity score was 30.4. The most common mechanism of injury involved fall from height, followed by bicycle accidents. Almost 50% of the patients underwent an emergency intervention. Almost 92% of the total population died because of the effects of the accident (primary trauma). Of these, 24% died during primary assessment in the emergency department. Most patients died because of the effects of severe head injury (63.4%), followed by exsanguination (17.6%). The most common type of complications causing death during treatment was respiratory failure (6.3%), followed by multiple organ failure (1.5%). Autopsy was performed in 10.4%. Organ donation procedure was performed in 14.5%. Permission for donation was not provided in almost 20% of the population. Conclusion The mortality rate in polytrauma patients in our institute is considerable and comparable with the international literature. Most patients die because of the effects of the accident (primary trauma). Autopsy and organ donation rates are low in our institution and leave room for substantial improvements in the future

    Systematic review and meta-analysis of the risk of bowel ischemia after ruptured abdominal aortic aneurysm repair

    No full text
    Objective: Outcomes after repair of ruptured abdominal aortic aneurysm (RAAA) have improved in the last decade. It is unknown whether this has resulted in a reduction of postoperative bowel ischemia (BI). The primary objective was to determine BI prevalence after RAAA repair. Secondary objectives were to determine its major sequelae and differences between open repair (OR) and endovascular aneurysm repair (EVAR). Methods: This systematic review (PROSPERO CRD42017055920) followed Preferred Reporting Items for Systematic Reviews and Meta-Analyses (PRISMA) and Meta-analysis Of Observational Studies in Epidemiology (MOOSE) guidelines. MEDLINE and Embase were searched for studies published from 2005 until 2018. The methodologic quality of observational studies was assessed with the Methodological Index for Non-Randomized Studies (MINORS) tool. The quality of the randomized controlled trials (RCTs) was assessed with the Cochrane Collaboration's tool for assessing risk of bias. BI prevalence and rates of BI as cause of death, reoperation, and bowel resection were estimated with meta-analyses with a random-effects model. Differences between OR and EVAR were estimated with pooled risk ratios with 95% confidence intervals (CIs). Changes over time were assessed with Spearman rank test (ρ). Publication bias was assessed with a funnel plot analysis. Results: A total of 101 studies with 52,670 patients were included; 72 studies were retrospective cohort studies, 14 studies were prospective cohort studies, 12 studies were retrospective administrative database studies, and 3 studies were RCTs. The overall methodologic quality of the RCTs was high, but that of observational studies was low. The pooled prevalence of BI ranged from of 0.08 (95% CI, 0.07-0.09) in database studies to 0.10 (95% CI, 0.08-0.12) in cohort studies. The risk of BI was higher after OR than after EVAR (risk ratio, 1.79; 95% CI, 1.25-2.57). The pooled rate of BI as cause of death was 0.04 (95% CI, 0.03-0.05), and that of BI as cause of reoperation and bowel resection ranged between 0.05 and 0.07. BI prevalence did not change over time (ρ −0.01; P =.93). The funnel plot analysis was highly suggestive of publication bias. Conclusions: The prevalence of clinically relevant BI after RAAA repair is approximately 10%. Approximately 5% of patients undergoing RAAA repair suffer from severe consequences of BI. BI is less prevalent after EVAR than after OR
    corecore