73 research outputs found

    Computer Aided Design of Self-Learning Robotic System using Imitation Learning

    Get PDF
    Artificial intelligence (AI), imitation learning, big data, cloud and distributed computing, robotics cells, and information communication technology, are some of the key tools and elements of the future digital and smart manufacturing facility. There are a number of challenges that digital and smart manufacturing is facing, especially with the complication of AI (i.e., machine, deep and cognitive learning) algorithms, great amount of data to process, and essential complex coding required, which makes immediate changes needed in manufacturing facilities not straightforward. This is notable in small manufacturing cells which is an integrated part of future smart factories such manufacturing facilities are usually needed some annual and regular updates to meet the update in the design specifications of next generation of products. Imitation learning is offering a great opportunity to overcome these challenges and simplify such complications, where human skills, ability to perform specific tasks, knowledge, and talent could be transferred. This is conveying the knowledge, and skills transfer using imitation learning. However, smart manufacturing and industrial revolution needs robotics cells that has skills beyond this, especially when it comes to process optimisation. Therefore, deep imitation learning could come in to help in the development of self-learning robotic systems and cells. Off course with the powerful tools such as distributed computing, blockchain, cloud computing, edge computing, and 5G the collaboration between such self-learning robotic cells will be possible. This will certainly not eliminate human existence but will enhance the manufacturing environment. This paper is focused on presenting the outcomes of CAD simulation and modelling phase of the ongoing research programme that focused on developing a self-learning robotic system using imitation learning. CAD tools have been used and some initial results is presented

    A Cold Atom Radio-Frequency Magnetometer

    Get PDF
    We propose and demonstrate a radio-frequency atomic magnetometer with sub-Doppler laser cooled rubidium-87. With a simple and compact design, our system demonstrates a sensitivity of 330 pT/ √ Hz in an unshielded environment, thus matching or surpassing previously reported cold atoms designs. By merging the multiple uses and robustness of radio-frequency atomic magnetometers with the detailed control of laser cooling, our cold atom radio-frequency magnetometer has the potential to move applications of atomic magnetometry to high spatial resolution. Direct impact in metrology for applied sciences, materials characterization, and nanotechnology can be anticipated

    A phase II study of mitomycin C, cisplatin and continuous infusion 5-fluorouracil (MCF) in the treatment of patients with carcinoma of unknown primary site

    Get PDF
    Carcinoma of unknown primary site remains a common clinical diagnosis, accounting for between 5 and 10% of all cancer patients. Numerous combination chemotherapy regimens have been used in the management of carcinoma of unknown primary site, resulting in response rates of 0–48%. We present the results of a single centre phase II study of the use of the combination of mitomycin C (7 mg m−2 on day 1 of cycles 1, 3 and 5) cisplatin (60 mg m−2 on day 1) and continuous infusion 5-fluorouracil (300 mg m−2 daily), MCF, delivered as a 21-day cycle, in patients with carcinoma of unknown primary site. Thirty-one patients with a diagnosis of carcinoma of unknown primary site were treated in Aberdeen Royal Infirmary between 1997 and 2001 with MCF. In total, 136 cycles of MCF were delivered (median of 5 cycles per patient). Toxicity was acceptable, with 19% grade 3 or 4 neutropenia, 16% grade 3 or 4 thrombocytopenia and 13% grade 3 or 4 nausea and vomiting. No cases of neutropenic sepsis were seen and there were no treatment-related deaths, however, six patients developed thrombotic complications. The overall response rate was 27% (CR 3%; PR 23%). Median time to progression was 3.4 months (95% CI 1.1–5.6 months) and median overall survival was 7.7 months (95% CI 5.7–9.8 months). Survival at 1 year was 28%, and at 2 years, 10%. MCF is a tolerable regimen with comparable toxicity, response rates and survival data to most platinum-based combination chemotherapy regimens in use for this devastating disease

    Genetic Analysis of Fin Development in Zebrafish Identifies Furin and Hemicentin1 as Potential Novel Fraser Syndrome Disease Genes

    Get PDF
    Using forward genetics, we have identified the genes mutated in two classes of zebrafish fin mutants. The mutants of the first class are characterized by defects in embryonic fin morphogenesis, which are due to mutations in a Laminin subunit or an Integrin alpha receptor, respectively. The mutants of the second class display characteristic blistering underneath the basement membrane of the fin epidermis. Three of them are due to mutations in zebrafish orthologues of FRAS1, FREM1, or FREM2, large basement membrane protein encoding genes that are mutated in mouse bleb mutants and in human patients suffering from Fraser Syndrome, a rare congenital condition characterized by syndactyly and cryptophthalmos. Fin blistering in a fourth group of zebrafish mutants is caused by mutations in Hemicentin1 (Hmcn1), another large extracellular matrix protein the function of which in vertebrates was hitherto unknown. Our mutant and dose-dependent interaction data suggest a potential involvement of Hmcn1 in Fraser complex-dependent basement membrane anchorage. Furthermore, we present biochemical and genetic data suggesting a role for the proprotein convertase FurinA in zebrafish fin development and cell surface shedding of Fras1 and Frem2, thereby allowing proper localization of the proteins within the basement membrane of forming fins. Finally, we identify the extracellular matrix protein Fibrillin2 as an indispensable interaction partner of Hmcn1. Thus we have defined a series of zebrafish mutants modelling Fraser Syndrome and have identified several implicated novel genes that might help to further elucidate the mechanisms of basement membrane anchorage and of the disease's aetiology. In addition, the novel genes might prove helpful to unravel the molecular nature of thus far unresolved cases of the human disease

    A Dominant-Negative Mutation of Mouse Lmx1b Causes Glaucoma and Is Semi-lethal via LBD1-Mediated Dimerisation

    Get PDF
    Mutations in the LIM-homeodomain transcription factor LMX1B cause nail-patella syndrome, an autosomal dominant pleiotrophic human disorder in which nail, patella and elbow dysplasia is associated with other skeletal abnormalities and variably nephropathy and glaucoma. It is thought to be a haploinsufficient disorder. Studies in the mouse have shown that during development Lmx1b controls limb dorsal-ventral patterning and is also required for kidney and eye development, midbrain-hindbrain boundary establishment and the specification of specific neuronal subtypes. Mice completely deficient for Lmx1b die at birth. In contrast to the situation in humans, heterozygous null mice do not have a mutant phenotype. Here we report a novel mouse mutant Icst, an N-ethyl-N-nitrosourea-induced missense substitution, V265D, in the homeodomain of LMX1B that abolishes DNA binding and thereby the ability to transactivate other genes. Although the homozygous phenotypic consequences of Icst and the null allele of Lmx1b are the same, heterozygous Icst elicits a phenotype whilst the null allele does not. Heterozygous Icst causes glaucomatous eye defects and is semi-lethal, probably due to kidney failure. We show that the null phenotype is rescued more effectively by an Lmx1b transgene than is Icst. Co-immunoprecipitation experiments show that both wild-type and Icst LMX1B are found in complexes with LIM domain binding protein 1 (LDB1), resulting in lower levels of functional LMX1B in Icst heterozygotes than null heterozygotes. We conclude that Icst is a dominant-negative allele of Lmx1b. These findings indicate a reassessment of whether nail-patella syndrome is always haploinsufficient. Furthermore, Icst is a rare example of a model of human glaucoma caused by mutation of the same gene in humans and mice

    Spinster Homolog 2 (Spns2) Deficiency Causes Early Onset Progressive Hearing Loss

    Get PDF
    Spinster homolog 2 (Spns2) acts as a Sphingosine-1-phosphate (S1P) transporter in zebrafish and mice, regulating heart development and lymphocyte trafficking respectively. S1P is a biologically active lysophospholipid with multiple roles in signalling. The mechanism of action of Spns2 is still elusive in mammals. Here, we report that Spns2-deficient mice rapidly lost auditory sensitivity and endocochlear potential (EP) from 2 to 3 weeks old. We found progressive degeneration of sensory hair cells in the organ of Corti, but the earliest defect was a decline in the EP, suggesting that dysfunction of the lateral wall was the primary lesion. In the lateral wall of adult mutants, we observed structural changes of marginal cell boundaries and of strial capillaries, and reduced expression of several key proteins involved in the generation of the EP (Kcnj10, Kcnq1, Gjb2 and Gjb6), but these changes were likely to be secondary. Permeability of the boundaries of the stria vascularis and of the strial capillaries appeared normal. We also found focal retinal degeneration and anomalies of retinal capillaries together with anterior eye defects in Spns2 mutant mice. Targeted inactivation of Spns2 in red blood cells, platelets, or lymphatic or vascular endothelial cells did not affect hearing, but targeted ablation of Spns2 in the cochlea using a Sox10-Cre allele produced a similar auditory phenotype to the original mutation, suggesting that local Spns2 expression is critical for hearing in mammals. These findings indicate that Spns2 is required for normal maintenance of the EP and hence for normal auditory function, and support a role for S1P signalling in hearing

    Diagnostic guidelines for the histological particle algorithm in the periprosthetic neo-synovial tissue

    Get PDF
    Background The identification of implant wear particles and non-implant related particles and the characterization of the inflammatory responses in the periprosthetic neo-synovial membrane, bone, and the synovial-like interface membrane (SLIM) play an important role for the evaluation of clinical outcome, correlation with radiological and implant retrieval studies, and understanding of the biological pathways contributing to implant failures in joint arthroplasty. The purpose of this study is to present a comprehensive histological particle algorithm (HPA) as a practical guide to particle identification at routine light microscopy examination. Methods The cases used for particle analysis were selected retrospectively from the archives of two institutions and were representative of the implant wear and non-implant related particle spectrum. All particle categories were described according to their size, shape, colour and properties observed at light microscopy, under polarized light, and after histochemical stains when necessary. A unified range of particle size, defined as a measure of length only, is proposed for the wear particles with five classes for polyethylene (PE) particles and four classes for conventional and corrosion metallic particles and ceramic particles. Results All implant wear and non-implant related particles were described and illustrated in detail by category. A particle scoring system for the periprosthetic tissue/SLIM is proposed as follows: 1) Wear particle identification at light microscopy with a two-step analysis at low (× 25, × 40, and × 100) and high magnification (× 200 and × 400); 2) Identification of the predominant wear particle type with size determination; 3) The presence of non-implant related endogenous and/or foreign particles. A guide for a comprehensive pathology report is also provided with sections for macroscopic and microscopic description, and diagnosis. Conclusions The HPA should be considered a standard for the histological analysis of periprosthetic neo-synovial membrane, bone, and SLIM. It provides a basic, standardized tool for the identification of implant wear and non-implant related particles at routine light microscopy examination and aims at reducing intra-observer and inter-observer variability to provide a common platform for multicentric implant retrieval/radiological/histological studies and valuable data for the risk assessment of implant performance for regional and national implant registries and government agencies

    Abstracts from the 3rd International Genomic Medicine Conference (3rd IGMC 2015)

    Get PDF
    corecore