324 research outputs found
First High Contrast Imaging Using a Gaussian Aperture Pupil Mask
Placing a pupil mask with a gaussian aperture into the optical train of
current telescopes represents a way to attain high contrast imaging that
potentially improves contrast by orders of magnitude compared to current
techniques. We present here the first observations ever using a gaussian
aperture pupil mask (GAPM) on the Penn State near-IR Imager and Spectrograph
(PIRIS) at the Mt. Wilson 100 telescope. Two nearby stars were
observed, Eridani and Her A. A faint companion was detected
around Her A, confirming it as a proper motion companion. Furthermore,
the observed H and K magnitudes of the companion were used to constrain its
nature. No companions or faint structure were observed for Eridani.
We found that our observations with the GAPM achieved contrast levels similar
to our coronographic images, without blocking light from the central star. The
mask's performance also nearly reached sensitivities reported for other ground
based adaptive optics coronographs and deep HST images, but did not reach
theoretically predicted contrast levels. We outline ways that could improve the
performance of the GAPM by an order of magnitude or more.Comment: 8 pages, 4 figures, accepted by ApJ letter
A Tunable Lyot Filter at Prime Focus: a Method for Tracing Supercluster Scales at z ~ 1
Tunable narrow-band, emission-line surveys have begun to show the ease with
which star forming galaxies can be identified in restricted redshift intervals
to z ~ 5 with a 4m class telescope. These surveys have been carried out with
imaging systems at the Cassegrain or Nasmyth focus and are therefore restricted
to fields smaller than 10 arcmin. We now show that tunable narrowband imaging
is possible over a 30 arcmin field with a high-performance Lyot filter placed
directly in front of a CCD mosaic at the prime focus. Our design is intended
for the f/3.3 prime focus of the AAT 3.9m, although similar devices can be
envisaged for the Subaru 8m (f/2), Palomar 5m (f/3.4), VISTA 4m (f/6), Mayall
4m (f/2.6) or CFHT 3.6m (f/4). A modified Wynne doublet ensures sub-arcsecond
performance over the field. In combination with the new Wide-Field Imaging 8K x
8K mosaic (WFI) at the AAT, the overall throughput (35%) of the system to
unpolarised light is expected to be comparable to the TAURUS Tunable Filter
(TTF). Unlike the TTF, the field is fully monochromatic and the instrumental
profile has much better wing suppression. For targetted surveys of
emission-line sources at z ~ 1, a low-resolution (R ~ 150 at 550nm) Lyot filter
on a 4m telescope is expected to be comparable or superior to current
instruments on 8-10m class telescopes. We demonstrate that the 30 arcmin field
is well matched to superclusters at these redshifts such that large-scale
structure should be directly observable.Comment: Astrophysical Journal, accepted. 53 pages, 16 figures, aaste
Break in the Mean and Persistence of Inflation: A Sectoral Analysis of French CPI
This paper uses disaggregated CPI time series to show that a break in the mean of French inflation occurred in the mid-eighties and that the 1983 monetary policy shift mostly accounted for it. CPI average yearly growth declined from nearly 11% before the break date (May 1985) to 2.1% after. No other break in the 1973-2004 sample period can be found. Controlling for this mean break, both aggregate and sectoral inflation persistence are stable and low, with the unit root lying far in the tail of the persistence estimates. However, persistence differs dramatically across sectors. Finally, the duration between two price changes (at the firm level) appears positively related with inflation persistence (at the aggregate level)
23rd IAEA Fusion Energy Conference: summary of sessions EX/C and ICC
An overview is given of recent experimental results in the areas of innovative confinement concepts, operational scenarios and confinement experiments as presented at the 2010 IAEA Fusion Energy Conference. Important new findings are presented from fusion devices worldwide, with a strong focus towards the scientific and technical issues associated with ITER and W7-X devices, presently under construction
Étude des niveaux de 3He par spectroscopie optique à très basse température
The hyperfine structure of 3He and the isotope shift Δ T(4He — 3He) in lines : λλ = 7 065 Å ; 4 713 Å ; 4 471 Å and 3 888 Å have been mesured using a double Fabry-Perot etalon spectrophotometer scanned by pressure and a hollow-cathode usually cooled by liquid helium below the λ-point ([FORMULE]). Results are as follows : [FORMULE]. Raies [FORMULE]. This work follows experiments on the fine structure of 4He which have been published recently[1].La structure hyperfine de 3He et le déplacement isotopique Δ T(4He — 3He) ont été étudiés sur les raies : λλ = 7 065 Å ; 5 875 Å ; 4 713 Å ; 4 471 Å et 3 888 Å, au moyen d'un spectrophotomètre à deux étalons de Fabry-Perot associés en série et d'une cathode creuse généralement refroidie à l'hélium liquide pompé ([FORMULE]). Les résultats sont les suivants (en mK) : [FORMULE]. Raies [FORMULE]. Ce travail fait suite à une étude récente de la structure fine de 4He [1]
- …