819 research outputs found
Microwave noise parameter measurements of a high temperature superconducting flux flow transistor
The noise parameters of a high-temperature superconducting (HTS) flux flow transistor made of TlBaCaCuO operating at 77 K and 3-5 GHz were experimentally determined. It is assumed that the dominant noise mechanism of the device, which is based on an array of weak links with a magnetic control line, is due to the statistical nature of flux nucleation and motion in the links. The noise parameters dictate the dependence of the noise figure on the source impedance, and are calculated by measuring source impedances. Sensitivity analysis is used to estimate the accuracy of the measurements. The measurements indicate a minimum noise figure of less than 1 dB at 3 GHzPeer ReviewedPostprint (published version
Flavor Physics in an SO(10) Grand Unified Model
In supersymmetric grand-unified models, the lepton mixing matrix can possibly
affect flavor-changing transitions in the quark sector. We present a detailed
analysis of a model proposed by Chang, Masiero and Murayama, in which the
near-maximal atmospheric neutrino mixing angle governs large new b -> s
transitions. Relating the supersymmetric low-energy parameters to seven new
parameters of this SO(10) GUT model, we perform a correlated study of several
flavor-changing neutral current (FCNC) processes. We find the current bound on
B(tau -> mu gamma) more constraining than B(B -> X_s gamma). The LEP limit on
the lightest Higgs boson mass implies an important lower bound on tan beta,
which in turn limits the size of the new FCNC transitions. Remarkably, the
combined analysis does not rule out large effects in B_s-B_s-bar mixing and we
can easily accomodate the large CP phase in the B_s-B_s-bar system which has
recently been inferred from a global analysis of CDF and DO data. The model
predicts a particle spectrum which is different from the popular Constrained
Minimal Supersymmetric Standard Model (CMSSM). B(tau -> mu gamma) enforces
heavy masses, typically above 1 TeV, for the sfermions of the degenerate first
two generations. However, the ratio of the third-generation and
first-generation sfermion masses is smaller than in the CMSSM and a (dominantly
right-handed) stop with mass below 500 GeV is possible.Comment: 44 pages, 5 figures. Footnote and references added, minor changes,
Fig. 2 corrected; journal versio
The Putative Liquid-Liquid Transition is a Liquid-Solid Transition in Atomistic Models of Water
We use numerical simulation to examine the possibility of a reversible
liquid-liquid transition in supercooled water and related systems. In
particular, for two atomistic models of water, we have computed free energies
as functions of multiple order parameters, where one is density and another
distinguishes crystal from liquid. For a range of temperatures and pressures,
separate free energy basins for liquid and crystal are found, conditions of
phase coexistence between these phases are demonstrated, and time scales for
equilibration are determined. We find that at no range of temperatures and
pressures is there more than a single liquid basin, even at conditions where
amorphous behavior is unstable with respect to the crystal. We find a similar
result for a related model of silicon. This result excludes the possibility of
the proposed liquid-liquid critical point for the models we have studied.
Further, we argue that behaviors others have attributed to a liquid-liquid
transition in water and related systems are in fact reflections of transitions
between liquid and crystal
Fourier Transform Infrared Spectroscopic Imaging and Multivariate Regression for Prediction of Proteoglycan Content of Articular Cartilage
Fourier Transform Infrared (FT-IR) spectroscopic imaging has been earlier applied for the spatial estimation of the collagen and the proteoglycan (PG) contents of articular cartilage (AC). However, earlier studies have been limited to the use of univariate analysis techniques. Current analysis methods lack the needed specificity for collagen and PGs. The aim of the present study was to evaluate the suitability of partial least squares regression (PLSR) and principal component regression (PCR) methods for the analysis of the PG content of AC. Multivariate regression models were compared with earlier used univariate methods and tested with a sample material consisting of healthy and enzymatically degraded steer AC. Chondroitinase ABC enzyme was used to increase the variation in PG content levels as compared to intact AC. Digital densitometric measurements of Safranin O –stained sections provided the reference for PG content. The results showed that multivariate regression models predict PG content of AC significantly better than earlier used absorbance spectrum (i.e. the area of carbohydrate region with or without amide I normalization) or second derivative spectrum univariate parameters. Increased molecular specificity favours the use of multivariate regression models, but they require more knowledge of chemometric analysis and extended laboratory resources for gathering reference data for establishing the models. When true molecular specificity is required, the multivariate models should be used
A cluster randomized controlled trial aimed at implementation of local quality improvement collaboratives to improve prescribing and test ordering performance of general practitioners: Study Protocol
<p>Abstract</p> <p>Background</p> <p>The use of guidelines in general practice is not optimal. Although evidence-based methods to improve guideline adherence are available, variation in physician adherence to general practice guidelines remains relatively high. The objective for this study is to transfer a quality improvement strategy based on audit, feedback, educational materials, and peer group discussion moderated by local opinion leaders to the field. The research questions are: is the multifaceted strategy implemented on a large scale as planned?; what is the effect on general practitioners' (GPs) test ordering and prescribing behaviour?; and what are the costs of implementing the strategy?</p> <p>Methods</p> <p>In order to evaluate the effects, costs and feasibility of this new strategy we plan a multi-centre cluster randomized controlled trial (RCT) with a balanced incomplete block design. Local GP groups in the south of the Netherlands already taking part in pharmacotherapeutic audit meeting groups, will be recruited by regional health officers. Approximately 50 groups of GPs will be randomly allocated to two arms. These GPs will be offered two different balanced sets of clinical topics. Each GP within a group will receive comparative feedback on test ordering and prescribing performance. The feedback will be discussed in the group and working agreements will be created after discussion of the guidelines and barriers to change. The data for the feedback will be collected from existing and newly formed databases, both at baseline and after one year.</p> <p>Discussion</p> <p>We are not aware of published studies on successes and failures of attempts to transfer to the stakeholders in the field a multifaceted strategy aimed at GPs' test ordering and prescribing behaviour. This pragmatic study will focus on compatibility with existing infrastructure, while permitting a certain degree of adaptation to local needs and routines.</p> <p>Trial registration</p> <p>Nederlands Trial Register ISRCTN40008171</p
Search for astronomical neutrinos from blazar TXS 0506+056 in super-kamiokande
We report a search for astronomical neutrinos in the energy region from several GeV to TeV in the direction of the blazar TXS 0506+056 using the Super-Kamiokande detector following the detection of a 100 TeV neutrinos from the same location by the IceCube collaboration. Using Super-Kamiokande neutrino data across several data samples observed from 1996 April to 2018 February we have searched for both a total excess above known backgrounds across the entire period as well as localized excesses on smaller timescales in that interval. No significant excess nor significant variation in the observed event rate are found in the blazar direction. Upper limits are placed on the electron- and muon-neutrino fluxes at the 90% confidence level as 6.0 × 10−7 and 4.5 × 10−7–9.3 × 10−10 [erg cm−2 s−1], respectively
Ex-vivo changes in amino acid concentrations from blood stored at room temperature or on ice: implications for arginine and taurine measurements
Background: Determination of the plasma concentrations of arginine and other amino acids is important for understanding pathophysiology, immunopathology and nutritional supplementation in human disease. Delays in processing of blood samples cause a change in amino acid concentrations, but this has not been precisely quantified. We aimed to describe the concentration time profile of twenty-two amino acids in blood from healthy volunteers, stored at room temperature or on ice.Methods: Venous blood was taken from six healthy volunteers and stored at room temperature or in an ice slurry. Plasma was separated at six time points over 24 hours and amino acid levels were determined by high-performance liquid chromatography.Results: Median plasma arginine concentrations decreased rapidly at room temperature, with a 6% decrease at 30 minutes, 25% decrease at 2 hours and 43% decrease at 24 hours. Plasma ornithine increased exponentially over the same period. Plasma arginine was stable in blood stored on ice, with a < 10% change over 24 hours. Plasma taurine increased by 100% over 24 hours, and this change was not prevented by ice. Most other amino acids increased over time at room temperature but not on ice.Conclusion: Plasma arginine concentrations in stored blood fall rapidly at room temperature, but remain stable on ice for at least 24 hours. Blood samples taken for the determination of plasma amino acid concentrations either should be placed immediately on ice or processed within 30 minutes of collection
- …