153 research outputs found
A Novel Microwave Sensor to Detect Specific Biomarkers in Human Cerebrospinal Fluid and Their Relationship to Cellular Ischemia During Thoracoabdominal Aortic Aneurysm Repair
Thoraco-abdominal aneurysms (TAAA) represents a particularly lethal vascular disease that without surgical repair carries a dismal prognosis. However, there is an inherent risk from
surgical repair of spinal cord ischaemia that can result in paraplegia. One method of reducing
this risk is cerebrospinal fluid (CSF) drainage. We believe that the CSF contains clinically
significant biomarkers that can indicate impending spinal cord ischaemia. This work
therefore presents a novel measurement method for proteins, namely albumin, as a precursor
to further work in this area. The work uses an interdigitated electrode (IDE) sensor and
shows that it is capable of detecting various concentrations of albumin (from 0 to 100 g/L)
with a high degree of repeatability at 200 MHz (R2 = 0.991) and 4 GHz (R2 = 0.975)
Surgical treatment of aortobronchial fistula after thoracic endograft failure
Endovascular stent grafting has been recently considered as a less invasive alternative to either medical therapy or open surgical treatment for many patients with descending thoracic aortic disease. Late complications are rarely described in literature. Herein, we described the occurrence of an aorto-bronchial fistula and a retro-A dissection in a 73-year-old man after stent-grafting for a penetrating atherosclerotic ulcer (PAU) of the descending thoracic aorta and the successful surgical technique adopted in order to remove the stent-graft
Successful management of an aortoesophageal fistula caused by a fish bone – case report and review of literature
We report a case of aortoesophageal fistula (AEF) caused by a fish bone that had a successful outcome. Aortoesophageal fistula is a rare complication of foreign body ingestion from which few patients survive. Over one hundred cases of AEF secondary to foreign body ingestion have been documented but only seven, including our case, have survived over 12 months. Treatment involved stabilising the patient with a Sengstaken-Blakemore tube and insertion of a thoracic aortic endovascular stent-graft. Unfortunately the stent became infected and definitive open surgical repair involved removing the stent, replacing the aorta with a homograft and coverage with a left trapezius flap while under deep hypothermic arrest
Outcome of open and endovascular repair in acute type B aortic dissection: a retrospective and observational study
Acute aortic dissection type A discloses Corpus alienum
We report an unusual case of an aortic type A dissection with a corpus alienum which compresses the right ventricle. The patient successfully underwent an aortic root replacement in deep hypothermia with re-implantation of the coronary arteries using a modified Bentall procedure and the resection of the corpus alienum. Intraoperative finding reveals 3 greatly adhered gauze compresses, which were most likely forgotten in the operation 34 years ago
Tratamento endovascular das doenças da aorta torácica: análise dos resultados de um centro
- …
