15 research outputs found

    Noninvasive cardiac output and blood pressure monitoring cannot replace an invasive monitoring system in critically ill patients

    Get PDF
    Background: Monitoring of cardiac output and blood pressure are standard procedures in critical care medicine. Traditionally, invasive techniques like pulmonary artery catheter (PAC) and arterial catheters are widely used. Invasiveness bears many risks of deleterious complications. Therefore, a noninvasive reliable cardiac output (CO) and blood pressure monitoring system could improve the safety of cardiac monitoring. The aim of the present study was to compare a noninvasive versus a standard invasive cardiovascular monitoring system. Methods: Nexfin HD is a continuous noninvasive blood pressure and cardiac output monitor system and is based on the development of the pulsatile unloading of the finger arterial walls using an inflatable finger cuff. During continuous BP measurement CO is calculated. We included 10 patients with standard invasive cardiac monitoring system (pulmonary artery catheter and arterial catheter) comparing invasively obtained data to the data collected noninvasively using the Nexfin HD. Results: Correlation between mean arterial pressure measured with the standard arterial monitoring system and the Nexfin HD was r2 = 0.67 with a bias of -2 mmHg and two standard deviations of ± 16 mmHg. Correlation between CO derived from PAC and the Nexfin HD was r2 = 0.83 with a bias of 0.23 l/min and two standard deviations of ± 2.1 l/min; the percentage error was 29%. Conclusion: Although the noninvasive CO measurement appears promising, the noninvasive blood pressure assessment is clearly less reliable than the invasively measured blood pressure. Therefore, according to the present data application of the Nexfin HD monitoring system in the ICU cannot be recommended generally. Whether such a tool might be reliable in certain critically ill patients remains to be determined

    Using theory to improve low back pain care in Australian Aboriginal primary care: a mixed method single cohort pilot study

    Get PDF
    Background: Low back pain (LBP) care is frequently discordant with research evidence. This pilot study evaluated changes in LBP care following a systematic, theory informed intervention in a rural Australian Aboriginal Health Service. We aimed to improve three aspects of care; reduce inappropriate LBP radiological imaging referrals, increase psychosocial oriented patient assessment and, increase the provision of LBP self-management information to patients. Methods: Three interventions to improve care were developed using a four-step systematic implementation approach. A mixed methods pre/post cohort design evaluated changes in the three behaviours using a clinical audit of LBP care in a six month period prior to the intervention and then following implementation. In-depth interviews elicited the perspectives of involved General Practitioners (GPs). Qualitative analysis was guided by the theoretical domains framework. Results: The proportion of patients who received guideline inconsistent imaging referrals (GICI) improved from 4.1 GICI per 10 patients to 0.4 (95 % CI for decrease in rate: 1.6 to 5.6) amongst GPs involved in the intervention. Amongst non-participating GPs (locum/part-time GPs who commenced post-interventions) the rate of GICI increased from 1.5 to 4.4 GICI per 10 patients (95 % CI for increase in rate: .5 to 5.3). There was a modest increase in the number of patients who received LBP self-management information from participating GPs and no substantial changes to psychosocial oriented patient assessments by any participants; however GPs qualitatively reported that their behaviours had changed. Knowledge and beliefs about consequences were important behavioural domains related to changes. Environmental and resource factors including protocols for locum staff and clinical tools embedded in patient management software were future strategies identified. Conclusions: A systematic intervention model resulted in partial improvements in LBP care. Determinants of practice change amongst GPs were increased knowledge of clinical guidelines, education delivered by someone considered a trusted source of information, and awareness of the negative consequences of inappropriate practices, especially radiological imaging on patient outcomes. Inconsistent and non-evidence based practices amongst locum GPs was an issue that emerged and will be a significant future challenge. The systematic approach utilised is applicable to other services interested in improving LBP care

    Efeito do exercĂ­cio fĂ­sico sobre o volume nasal Effects of physical exercise in nasal volume

    No full text
    A variação da permeabilidade nasal tem sido demonstrada usando-se vĂĄrias tĂ©cnicas de exame. As estruturas nasais geram uma resistĂȘncia que representa cerca de 50% da resistĂȘncia respiratĂłria total. O exercĂ­cio fĂ­sico Ă© um dos fatores que pode causar um efeito vasoconstritor sobre a mucosa nasal. OBJETIVO: O objetivo deste estudo Ă© avaliar o grau de mudança do volume nasal apĂłs exercĂ­cio fĂ­sico e o tempo de retorno aos nĂ­veis basais. MATERIAIS E MÉTODOS: Dezenove indivĂ­duos foram submetidos Ă  realização de teste fĂ­sico em bicicleta ergomĂ©trica. O volume nasal foi obtido atravĂ©s da rinometria acĂșstica, realizada em repouso, apĂłs o fim do exercĂ­cio fĂ­sico, e nos minutos dĂ©cimo e vigĂ©simo de seu final. RESULTADOS: Os resultados rinomĂ©tricos mostram um aumento estatisticamente significativo do volume nasal (p < 0,001). No vigĂ©simo minuto o volume nasal estava prĂłximo aos nĂ­veis de repouso. CONCLUSÃO: O exercĂ­cio fĂ­sico de modo geral aumenta significativamente o volume nasal. Entretanto, o aumento do volume nasal foi transitĂłrio, ocorrendo uma maior redução deste aumento nos primeiros dez minutos apĂłs o final do exercĂ­cio. No vigĂ©simo minuto apĂłs o fim do exercĂ­cio fĂ­sico, os valores do volume nasal retornam prĂłximos aos valores de repouso.<br>The nasal permeability has been demonstrated using several exams. Nasal structures produces a resistance to the nasal air flux that represents over 50% of the total respiratory resistance. Physical exercises is a factor that brings a vasoconstrictor effect over nasal mucosa. AINS: Evaluate the improvement degree of nasal volume after aerobic physical exercises and time to return to previous levels. SUBJECTS AND METHODS: Nineteen heathly subjects were submitted to aerobic exercise in ergometric bike. The nasal volume was obtained by Acoustic Rhinometry perfomed in rest, after aerobic exercise, 10o and 20o minutes after the aerobic exercise. RESULTS: Rhynometrics results shows a statically and significant increase of nasal volume (p<0,001). The nasal volume, in twenty minutes, returns nearby the rest levels. CONCLUSIONS: Aerobic exercises, generally, increases the nasal volume. However, the increase of nasal volume was transitory, and occurs a major reduction of increase in the first ten minutes after the exercises ends, and perform a greater vasoconstrictor effect over nasal mucosa, Twenty minutes after the physical exercises finish, total nasal volume returns, closely, to the basal levels

    Surfactant-derived proteins as markers of alveolar membrane damage in heart failure.

    Get PDF
    Background: In heart failure (HF) alveolar-capillary membrane is abnormal. Surfactant-derived proteins (SPs) and plasma receptor for advanced-glycation-end-products (RAGE) have been proposed as lung damage markers. Methods: Eighty-nine chronic HF and 17 healthy subjects were evaluated by echocardiography, blood parameters, carbon monoxide lung diffusion (DLCO) and cardiopulmonary exercise test. We measured immature SP-B, mature SP-B, SP-A, SP-D and RAGE plasma levels. Results: Immature SP-B (arbitrary units), mature SP-A (ng/ml) and SP-D (ng/ml), but not mature SP-B (ng/ml) and RAGE (pg/ml) levels, were higher in HF than in controls [immature SP-B: 15.6 (13.1, 75th-25th interquartile range) Vs. 11.1 (6.4), p<0.01; SP-A, 29.6 (20.1) Vs. 18.3 (13.5), p=0.01; SP-D: 125 (90) Vs. 78 (58), p<0.01]. Immature SP-B, SP-A, SP-D and RAGE values were related to DLCO, peak oxygen consumption, ventilatory efficiency, and brain natriuretic peptide (BNP), whereas plasma mature SP-B was not. The DLCO Vs. immature SP-B correlation was the strongest one. At multivariate analysis, RAGE was associated to age and creatinine, SP-A to DLCO and BNP, SP-D to BNP, mature SP-B to DLCO and creatinine, and immature SP-B only but strongly to DLCO. Conclusions: Immature SP-B is the most reliable biological marker of alveolar-capillary membrane function in HF
    corecore