480 research outputs found

    Lessons Learned from Recent Testing in the Nuclear Thermal Rocket Element Environmental Simulator

    Get PDF
    The Nuclear Thermal Rocket Element Environmental Simulator (NTREES) facility is designed to perform realistic non-nuclear testing of nuclear thermal rocket (NTR) fuel elements and fuel materials. Although the NTREES facility cannot reproduce the neutron and gamma environment of an operating NTR, it can simulate the thermal hydraulic environment within an NTR fuel element to provide critical information on material performance and compatibility. The NTREES facility is currently being reconfigured with an all new suite of pyrometers, a new coil and feedthrough design along with a new gas sampling system for the mass spectrometer. Also new is the ability to perform chamber purges using argon. All of these modifications are the result of experiences gained through several years of testing various NTR components under a wide range of operating conditions. The testing details and the lessons learned from those tests are discussed in this presentation

    Initial Operation of the Nuclear Thermal Rocket Element Environmental Simulator

    Get PDF
    The Nuclear Thermal Rocket Element Environmental Simulator (NTREES) facility is designed to perform realistic non-nuclear testing of nuclear thermal rocket (NTR) fuel elements and fuel materials. Although the NTREES facility cannot mimic the neutron and gamma environment of an operating NTR, it can simulate the thermal hydraulic environment within an NTR fuel element to provide critical information on material performance and compatibility. The NTREES facility has recently been upgraded such that the power capabilities of the facility have been increased significantly. At its present 1.2 MW power level, more prototypical fuel element temperatures nay now be reached. The new 1.2 MW induction heater consists of three physical units consisting of a transformer, rectifier, and inverter. This multiunit arrangement facilitated increasing the flexibility of the induction heater by more easily allowing variable frequency operation. Frequency ranges between 20 and 60 kHz can accommodated in the new induction heater allowing more representative power distributions to be generated within the test elements. The water cooling system was also upgraded to so as to be capable of removing 100% of the heat generated during testing In this new higher power configuration, NTREES will be capable of testing fuel elements and fuel materials at near-prototypic power densities. As checkout testing progressed and as higher power levels were achieved, several design deficiencies were discovered and fixed. Most of these design deficiencies were related to stray RF energy causing various components to encounter unexpected heating. Copper shielding around these components largely eliminated these problems. Other problems encountered involved unexpected movement in the coil due to electromagnetic forces and electrical arcing between the coil and a dummy test article. The coil movement and arcing which were encountered during the checkout testing effectively destroyed the induction coil in use at the time and resulted in NTREES being out of commission for a couple of months while a new stronger coil was procured. The new coil includes several additional pieces of support structure to prevent coil movement in the future. In addition, new insulating test article support components have been fabricated to prevent unexpected arcing to the test articles. Additional activities are also now underway to address ways in which the radial temperature profiles across test articles may be controlled such that they are more prototypical of what they would encounter in an operating nuclear engine. The causes of the temperature distribution problem are twofold. First, the fuel element test article is isolated in NTREES as opposed to being in the midst of many other mostly identical fuel elements in a nuclear engine. As a result, the fuel element heat flux boundary conditions in NTREES are far from adiabatic as would normally be the case in a reactor. Second, induction heating skews the power distribution such that power is preferentially deposited near the outside of the fuel element. Nuclear heating, conversely, deposits its power much more uniformly throughout the fuel element. Current studies are now looking at various schemes to adjust the amount of thermal radiation emitted from the fuel element surface so as to essentially vary the thermal boundary conditions on the test article. It is hoped that by properly adjusting the thermal boundary conditions on the fuel element test article, it may be possible to substantially correct for the inappropriate radial power distributions resulting from the induction heating so as to yield a more nearly correct temperature distribution throughout the fuel element

    Performance of an Annular Linear Induction Pump with Applications to Space Nuclear Power Systems

    Get PDF
    Results of performance testing of an annular linear induction pump are presented. The pump electromagnetically pumps liquid metal through a circuit specially designed to allow for quantification of the performance. Testing was conducted over a range of conditions, including frequencies of 33, 36, 39, and 60 Hz, liquid metal temperatures from 125 to 525 C, and input voltages from 5 to 120 V. Pump performance spanned a range of flow rates from roughly 0.16 to 5.7 L/s (2.5 to 90 gpm), and pressure head less than 1 to 90 kPa (less than 0.145 to 13 psi). The maximum efficiency measured during testing was slightly greater than 6%. The efficiency was fairly insensitive to input frequency from 33 to 39 Hz, and was markedly lower at 60 Hz. In addition, the efficiency decreased as the NaK temperature was raised. The performance of the pump operating on a variable frequency drive providing 60 Hz power compared favorably with the same pump operating on 60 Hz power drawn directly from the electrical grid

    Association of Patient and Visit Characteristics With Rate and Timing of Urologic Procedures for Patients Discharged From the Emergency Department With Renal Colic

    Get PDF
    Importance: Little is known about the timing of urologic interventions in patients with renal colic discharged from the emergency department. Understanding patients\u27 likelihood of a subsequent urologic intervention could inform decision-making in this population. Objectives: To examine the rate and timing of urologic procedures performed after an emergency department visit for renal colic and the factors associated with receipt of an intervention. Design, Setting, and Participants: This retrospective cohort study used the Massachusetts All Payers Claims Database to identify patients 18 to 64 years of age who were seen in a Massachusetts emergency department for renal colic from January 1, 2011, to October 31, 2014, Patients were identified via International Classification of Diseases, Ninth Revision codes, and all medical care was linked, enabling identification of subsequent health care use. Data analysis was performed from January 1, 2017, to December 31, 2018. Main Outcomes and Measures: The main outcome was receipt of urologic procedure within 60 days. Secondary outcomes included rates of return emergency department visit and urologic and primary care follow-up. Results: A total of 66218 unique index visits by 55314 patients (mean [SD] age, 42.6 [12.4] years; 33 590 [50.7%] female; 25 411 [38.4%] Medicaid insured) were included in the study. A total of 5851 patients (8.8%) had visits resulting in admission at the index encounter, and 1774 (2.7%) had visits resulting in a urologic procedure during that admission. Of the 60367 patient visits resulting in discharge from the emergency department, 3018 (5.0%) led to a urologic procedure within 7 days, 4407 (7.3%) within 14 days, 5916 (9.8%) within 28 days, and 7667 (12.7%) within 60 days. A total of 3226 visits (5.3%) led to a subsequent emergency department visit within 7 days and 6792 (11.3%) within 60 days. For the entire cohort (admitted and discharged patients), 39 189 (59.2%) had contact with a urologist or primary care practitioner within 60 days. Having Medicaid-only insurance was associated with lower rates of urologic procedures (odds ratio, 0.70; 95% CI, 0.66-0.74) and urologic follow-up (5.6% vs 8.8%; P \u3c .001) and higher rates of primary care follow-up (59.2% vs 47.2%; P \u3c .001) compared with patients with all other insurance types. Conclusions and Relevance: In this cohort study, most adult patients younger than 65 years who were discharged from the emergency department with a diagnosis of renal colic did not undergo a procedure or see a urologist within 60 days. This finding has implications for both the emergency department and outpatient treatment of these patients

    Composite-pulse magnetometry with a solid-state quantum sensor

    Get PDF
    The sensitivity of quantum magnetometers is challenged by control errors and, especially in the solid-state, by their short coherence times. Refocusing techniques can overcome these limitations and improve the sensitivity to periodic fields, but they come at the cost of reduced bandwidth and cannot be applied to sense static (DC) or aperiodic fields. Here we experimentally demonstrate that continuous driving of the sensor spin by a composite pulse known as rotary-echo (RE) yields a flexible magnetometry scheme, mitigating both driving power imperfections and decoherence. A suitable choice of RE parameters compensates for different scenarios of noise strength and origin. The method can be applied to nanoscale sensing in variable environments or to realize noise spectroscopy. In a room-temperature implementation based on a single electronic spin in diamond, composite-pulse magnetometry provides a tunable trade-off between sensitivities in the microT/sqrt(Hz) range, comparable to those obtained with Ramsey spectroscopy, and coherence times approaching T1

    The short-term effect of high versus moderate protein intake on recovery after strength training in resistance-trained individuals

    Get PDF
    Background: Dietary protein intakes up to 2.9 g.kg-1.d-1 and protein consumption before and after resistance training may enhance recovery, resulting in hypertrophy and strength gains. However, it remains unclear whether protein quantity or nutrient timing is central to positive adaptations. This study investigated the effect of total dietary protein content, whilst controlling for protein timing, on recovery in resistance trainees. Methods: Fourteen resistance-trained individuals underwent two 10-day isocaloric dietary regimes with a protein content of 1.8 g.kg-1.d-1 (PROMOD) or 2.9 g.kg-1.d-1 (PROHIGH) in a randomised, counterbalanced, crossover design. On days 8-10 (T1-T3), participants undertook resistance exercise under controlled conditions, performing 3 sets of squat, bench press and bent-over rows at 80% 1 repetition maximum until volitional exhaustion. Additionally, participants consumed a 0.4 g.kg-1 whey protein concentrate/isolate mix 30 minutes before and after exercise sessions to standardise protein timing specific to training. Recovery was assessed via daily repetition performance, muscle soreness, bioelectrical impedance phase angle, plasma creatine kinase (CK) and tumor necrosis factor-Ξ± (TNF-Ξ±). Results: No significant differences were reported between conditions for any of the performance repetition count variables (p>0.05). However, within PROMOD only, squat performance total repetition count was significantly lower at T3 (19.7 Β± 6.8) compared to T1 (23.0 Β± 7.5; p=0.006). Pre and post-exercise CK concentrations significantly increased across test days (p≀0.003), although no differences were reported between conditions. No differences for TNF-Ξ± or muscle soreness were reported between dietary conditions. Phase angle was significantly greater at T3 for PROHIGH (8.26 Β± 0.82Β°) compared with PROMOD (8.08 Β± 0.80Β°; p=0.012). Conclusions: When energy intake and peri-exercise protein intake was controlled for, a short term PROHIGH diet did not improve markers of muscle damage or soreness in comparison to a PROMOD approach following repeated days of intensive training. Whilst it is therefore likely that protein intakes (1.8g.kg-1.d-1) may be sufficient for resistance-trained individuals, it is noteworthy that both lower body exercise performance and bioelectrical phase angle were maintained with PROHIGH. Longer term interventions are warranted to determine whether PROMOD intakes are sufficient during prolonged training periods or when extensive exercise (e.g. training twice daily) is undertaken

    Formyl Peptide Receptor as a Novel Therapeutic Target for Anxiety-Related Disorders

    Get PDF
    Formyl peptide receptors (FPR) belong to a family of sensors of the immune system that detect microbe-associated molecules and inform various cellular and sensorial mechanisms to the presence of pathogens in the host. Here we demonstrate that Fpr2/3-deficient mice show a distinct profile of behaviour characterised by reduced anxiety in the marble burying and light-dark box paradigms, increased exploratory behaviour in an open-field, together with superior performance on a novel object recognition test. Pharmacological blockade with a formyl peptide receptor antagonist, Boc2, in wild type mice reproduced most of the behavioural changes observed in the Fpr2/3(-/-) mice, including a significant improvement in novel object discrimination and reduced anxiety in a light/dark shuttle test. These effects were associated with reduced FPR signalling in the gut as shown by the significant reduction in the levels of p-p38. Collectively, these findings suggest that homeostatic FPR signalling exerts a modulatory effect on anxiety-like behaviours. These findings thus suggest that therapies targeting FPRs may be a novel approach to ameliorate behavioural abnormalities present in neuropsychiatric disorders at the cognitive-emotional interface

    Age-related difference in susceptibility of ApcMin/+ mice towards the chemopreventive efficacy of dietary aspirin and curcumin

    Get PDF
    The nonsteroidal anti-inflammatory drug aspirin and the spice curcumin retard adenoma formation when administered long-term to ApcMin/+ mice, a model of human familial adenomatous polyposis coli. Both agents interfere with cyclooxygenase activity. When aspirin is administered to ApcMin/+ mice only postweaning, but not before, it is inefficacious, while curcumin given postweaning is active. Here the hypothesis was tested that dietary aspirin (0.05%) or curcumin (0.2%) prevent or delay adenoma formation in offsprings when administered to ApcMin/+ mothers and up to the end of weaning, but not afterwards. Whereas curcumin was without effect when administered in this way, aspirin reduced numbers of intestinal adenomas by 21%. When aspirin given up to the end of weaning was combined with curcumin administered from the end of weaning for the rest of the animals' lifetime, intestinal adenoma numbers were reduced by 38%. The combination was not superior to intervention postweaning with curcumin alone. These results show that aspirin exerts chemopreventive activity in the ApcMin/+ mouse during tumour initiation/early promotion, while curcumin is efficacious when given at a later stage of carcinogenic progression. Thus, the results suggest that in this mouse model aspirin and curcumin act during different β€˜windows’ of neoplastic development
    • …
    corecore