6,184 research outputs found

    Energy and precious fuels requirements of fuel alcohol production. Volume 2, appendices A and B: Ethanol from grain

    Get PDF
    Energy currently used in grain production, the effect of ethanol production on agricultural energy consumption, energy credits for ethanol by-products, and land availability and the potential for obtaining ethanol from grain are discussed. Dry milling, wet milling, sensitivity analysis, potential for reduced energy consumption are also discussed

    Interlaminar shear stress effects on the postbuckling response of graphite-epoxy panels

    Get PDF
    The influence of shear flexibility on overall postbuckling response was assessed, and transverse shear stress distributions in relation to panel failure were examined. Nonlinear postbuckling results are obtained for finite element models based on classical laminated plate theory and first-order shear deformation theory. Good correlation between test and analysis is obtained. The results presented analytically substantiate the experimentally observed failure mode

    Virtual pedagogy initiative revisited

    Get PDF

    Aeroelastic Stability and Response of Rotating Structures

    Get PDF
    A summary of the work performed from 1996 to 1997 is presented. More details can be found in the cited references. This grant led to the development of aeroelastic analyses methods for predicting flutter and forced response in fans, compressors, and turbines using computationa

    Prediction of Fluctuations in Crop-hail Loss Data

    Get PDF
    published or submitted for publicationis peer reviewedOpe

    Knowledge Organization and Inference Engine for the WVU Face Decision Support System

    Get PDF
    The knowledge-based organization for the West Virginia University Face Decision Support System is given, along with the initial development of the associated inference engine. The knowledge base contains generic knowledge about underground coal mines that utilize continuous miners. A typical knowledge entry is given, and the inference engine methodology is explained. The engine utilizes this knowledge with data from monitoring systems and from interaction with the section foreman, to assist in making section management decisions and plans

    Phosphorylation and activation of protamine kinase by two forms of a myelin basic protein kinase from extracts of bovine kidney cortex

    Get PDF
    Two myelin basic protein kinases designated MBPK-1 and MBPK-2 were purified to apparent homogeneity from extracts of bovine kidney cortex. The purified preparations exhibited an apparent M(r) ≃ 40,000 by sodium dodecyl sulfate-polyacrylamide gel electrophoresis and ~42,000 (MBPK-1) and 45,000 (MBPK-2) by gel permeation chromatography. Up to 0.4 and 1.8 mol of phosphoryl groups were incorporated per mol of MBPK-1 and MBPK-2, respectively, on threonines following incubation with ATP. Autophosphorylation, incubation with protein phosphatase 2A2 (PP2A2), CD45, or T-cell protein tyrosine phosphatase did not affect MBPK-1 activity. Autophosphorylation increased by about 3-fold MBPK-2 activity. This autophosphorylation and activation was reversed by PP2A2 but not by CD45 or T-cell protein tyrosine phosphatase. MBPK-1 and MBPK-2 displayed a positive reaction with an antibody to mitogen-activated protein kinase. Purified preparations of protamine kinase were activated by about 1.5-6-fold and, after inactivation with PP2A2, were reactivated by about 30% by MBPK-1 and MBPK-2. Activation and reactivation correlated with the incorporation, respectively, of 0.1-0.5 and 0.5 mol of phosphoryl groups/mol of the protamine kinase on serines. The results show that MBPK-1 and MBPK-2 are protamine kinase-activating kinases and suggest that MBPK-1 and MBPK-2 may be related to mitogen-activated protein kinase

    Inert gas clearance from tissue by co-currently and counter-currently arranged microvessels

    Get PDF
    To elucidate the clearance of dissolved inert gas from tissues, we have developed numerical models of gas transport in a cylindrical block of tissue supplied by one or two capillaries. With two capillaries, attention is given to the effects of co-current and counter-current flow on tissue gas clearance. Clearance by counter-current flow is compared with clearance by a single capillary or by two co-currently arranged capillaries. Effects of the blood velocity, solubility, and diffusivity of the gas in the tissue are investigated using parameters with physiological values. It is found that under the conditions investigated, almost identical clearances are achieved by a single capillary as by a co-current pair when the total flow per tissue volume in each unit is the same (i.e., flow velocity in the single capillary is twice that in each co-current vessel). For both co-current and counter-current arrangements, approximate linear relations exist between the tissue gas clearance rate and tissue blood perfusion rate. However, the counter-current arrangement of capillaries results in less-efficient clearance of the inert gas from tissues. Furthermore, this difference in efficiency increases at higher blood flow rates. At a given blood flow, the simple conduction-capacitance model, which has been used to estimate tissue blood perfusion rate from inert gas clearance, underestimates gas clearance rates predicted by the numerical models for single vessel or for two vessels with co-current flow. This difference is accounted for in discussion, which also considers the choice of parameters and possible effects of microvascular architecture on the interpretation of tissue inert gas clearance

    Pediatric Esophageal Dilatations: A Cross-Specialty Experience

    Get PDF
    AIM OF THE STUDY: Esophageal dilatations are commonly performed in pediatric patients who have undergone an esophageal atresia/tracheoesophageal fistula (EA/TEF) repair or following caustic injury. We sought to compare the practice of esophageal dilatation across different specialties. METHODS: We analyzed all patients who had an esophageal dilatation at our center between April 2014 and December 2018. Patients were identified via prospectively maintained databases and clinical coding records. Patients had a combination of dilatations under each specialty: interventional radiology (IR), surgery, and gastroenterology. RESULTS: Thirty-five individual patients underwent 226 dilatations, median dilatations per patient was 3 (1–40). The median age at first dilatation was 18 months (1–194 months). Sixty-eight percent of patients had a previous EA/TEF repair. IR performed 59% of dilatations, surgeons 26%, and 15% by gastroenterologists. Surgeons more frequently were performing initial dilatations (P < .05) and performed more dilatations in EA/TEF patients (P < .0001). There was a significant difference between the time from a surgical dilatation until the next dilatation, 3.7 months, compared with an IR dilatation, 1.8 months (ANOVA, P < .05). Surgeons more frequently increased the size of balloon used (57% versus 33% versus 39%, P < .01). There was no significant difference in balloon size between specialties or in the incremental increase in size between subsequent dilatations. There was one postprocedure perforation, managed conservatively (complication rate = 0.4%). CONCLUSIONS: We have demonstrated that on average, patients wait longer after a surgical dilatation until their next procedure, and surgical teams are more likely to increase the size of the dilating balloon. Surgeons tend to be more involved in their postoperative patients in the initial phases of stricture management. Our results suggest the feasibility and safety of a multispecialty approach for these patients

    Contact force sensing in ablation of ventricular arrhythmias using a 56-hole open-irrigation catheter: a propensity-matched analysis.

    Get PDF
    PURPOSE: The effect of adding contact force (CF) sensing to 56-hole tip irrigation in ventricular arrhythmia (VA) ablation has not been previously studied. We aimed to compare outcomes with and without CF sensing in VA ablation using a 56-hole radiofrequency (RF) catheter. METHODS: A total of 164 patients who underwent first-time VA ablation using Thermocool SmartTouch Surround Flow (TC-STSF) catheter (Biosense-Webster, Diamond Bar, CA, USA) were propensity-matched in a 1:1 fashion to 164 patients who had first-time ablation using Thermocool Surround Flow (TC-SF) catheter. Patients were matched for age, gender, cardiac aetiology, ejection fraction and approach. Acute success, complications and long-term follow-up were compared. RESULTS: There was no difference between procedures utilising either TC-SF or TC-STSF in acute success (TC-SF: 134/164 (82%), TC-STSF: 141/164 (86%), p = 0.3), complications (TC-SF: 11/164 (6.7%), TC-STSF: 11/164 (6.7%), p = 1.0) or VA-free survival (TC-SF: mean arrhythmia-free survival time = 5.9 years, 95% CI = 5.4-6.4, TC-STSF: mean = 3.2 years, 95% CI = 3-3.5, log-rank p = 0.74). Fluoroscopy time was longer in normal hearts with TC-SF (19 min, IQR: 14-30) than TC-STSF (14 min, IQR: 8-25; p = 0.04). CONCLUSION: Both TC-SF and TC-STSF catheters are safe and effective in treating VAs. The use of CF sensing catheters did not improve safety or acute and long-term outcomes, but reduced fluoroscopy time in normal heart VA
    • …
    corecore