2,546 research outputs found

    Longer duration of obesity is associated with a reduction in urinary angiotensinogen in prepubertal children

    Get PDF
    Background: We aimed to study the impact of obesity on urinary excretion of angiotensinogen (U-AGT) in prepubertal children, focusing on the duration of obesity and gender. Also, we aimed to evaluate whether plasma angiotensinogen (P-AGT) and hydrogen peroxide (H2O2) play a role in the putative association. Methods: Cross-sectional evaluation of 305 children aged 8–9 years (160 normal weight, 86 overweight, and 59 obese). Anthropometric measurements and 24-h ambulatory blood pressure monitoring were performed. Angiotensinogen (AGT) was determined by a commercial enzyme-linked immunosorbent assay (ELISA) kit and H2O2 by a microplate fluorometric assay. Results: U-AGT and P-AGT levels were similar across body mass index (BMI) groups and between sexes. However, boys who were overweight/obese since the age of 4 years presented lower levels of U-AGT compared with those of normal weight at the same age. In children who were overweight/obese since the age of 4, urinary H2O2 decreased with P-AGT. Conclusions: A higher duration of obesity was associated with decreased U-AGT in boys, thus reflecting decreased intrarenal activity of the renin–angiotensin system. Also, children with a longer duration of obesity showed an inverse association between urinary H2O2 and P-AGT. Future studies should address whether these results reflect an early compensatory mechanism to limit obesity-triggered renal dysfunction.This project was supported by funds from Fundo Europeu de Desenvolvimento Regional (FEDER) from Programa Operacional Factores de Competitividade – COMPETE (FCOMP-01-0124-FEDER-028751), by national funds from the Portuguese Foundation for Science and Technology (FCT) (PTDC/DTP-PIC/0239/2012) and by Calouste Gulbenkian Foundation, that granted the study design and data collection and analysis. Liane Correia-Costa was supported by FCT (grant SFRH/SINTD/95898/2013), Teresa Sousa was supported by FCT and POPH/FSE (EC) (Ciência 2008 and SFRH/BPD/112005) and Franz Schaefer was supported by the ERA-EDTA Research Programme and the KfH Foundation for Preventive Medicine. The Epidemiology Research Unit (EPIUnit) is funded by FCT (UID/DTP/04750/2013)

    Low volume in vitro diagnostic proton NMR spectroscopy of human blood plasma for lipoprotein and metabolite analysis: application to SARS-CoV-2 biomarkers.

    Get PDF
    The utility of low sample volume in vitro diagnostic (IVDr) proton nuclear magnetic resonance (1H NMR) spectroscopic experiments on blood plasma for information recovery from limited availability or high value samples was exemplified using plasma from patients with SARS-CoV-2 infection and normal controls. 1H NMR spectra were obtained using solvent-suppressed 1D, spin-echo (CPMG), and 2-dimensional J-resolved (JRES) spectroscopy using both 3 mm outer diameter SampleJet NMR tubes (100 μL plasma) and 5 mm SampleJet NMR tubes (300 μL plasma) under in vitro diagnostic conditions. We noted near identical diagnostic models in both standard and low volume IVDr lipoprotein analysis (measuring 112 lipoprotein parameters) with a comparison of the two tubes yielding R2 values ranging between 0.82 and 0.99 for the 40 paired lipoprotein parameters samples. Lipoprotein measurements for the 3 mm tubes were achieved without time penalty over the 5 mm tubes as defined by biomarker recovery for SARS-CoV-2. Overall, biomarker pattern recovery for the lipoproteins was extremely similar, but there were some small positive offsets in the linear equations for several variables due to small shimming artifacts, but there was minimal degradation of the biological information. For the standard untargeted 1D, CPMG, and JRES NMR experiments on the same samples, the reduced signal-to-noise was more constraining and required greater scanning times to achieve similar differential diagnostic performance (15 min per sample per experiment for 3 mm 1D and CPMG, compared to 4 min for the 5 mm tubes). We conclude that the 3 mm IVDr method is fit-for-purpose for quantitative lipoprotein measurements, allowing the preparation of smaller volumes for high value or limited volume samples that is common in clinical studies. If there are no analytical time constraints, the lower volume experiments are equally informative for untargeted profiling

    Overview of (pro-)Lie group structures on Hopf algebra character groups

    Full text link
    Character groups of Hopf algebras appear in a variety of mathematical and physical contexts. To name just a few, they arise in non-commutative geometry, renormalisation of quantum field theory, and numerical analysis. In the present article we review recent results on the structure of character groups of Hopf algebras as infinite-dimensional (pro-)Lie groups. It turns out that under mild assumptions on the Hopf algebra or the target algebra the character groups possess strong structural properties. Moreover, these properties are of interest in applications of these groups outside of Lie theory. We emphasise this point in the context of two main examples: The Butcher group from numerical analysis and character groups which arise from the Connes--Kreimer theory of renormalisation of quantum field theories.Comment: 31 pages, precursor and companion to arXiv:1704.01099, Workshop on "New Developments in Discrete Mechanics, Geometric Integration and Lie-Butcher Series", May 25-28, 2015, ICMAT, Madrid, Spai

    In the Shadow of the Transiting Disk: Imaging epsilon Aurigae in Eclipse

    Full text link
    Eclipses of the single-line spectroscopic binary star, epsilon Aurigae, provide an opportunity to study the poorly-defined companion. We used the MIRC beam combiner on the CHARA array to create interferometric images during eclipse ingress. Our results demonstrate that the eclipsing body is a dark disk that is opaque and tilted, and therefore exclude alternative models for the system. These data constrain the geometry and masses of the components, providing evidence that the F-star is not a massive supergiant star.Comment: As submitted to Nature. Published in Nature April 8, 2010

    Quantitative lipoprotein subclass and low molecular weight metabolite analysis in human serum and plasma by 1H NMR spectroscopy in a multilaboratory trial

    Get PDF
    We report an extensive 600 MHz NMR trial of a quantitative lipoprotein and small molecule measurements in human blood serum and plasma. Five centers with eleven 600 MHz NMR spectrometers were used to analyze 98 samples including: 20 QCs, 37 commercially sourced, paired serum and plasma samples and 2 National Institute of Science and Technology, NIST, reference material 1951c replicates. Samples were analyzed using rigorous protocols for sample preparation and experimental acquisition. A commercial lipoprotein subclass analysis was used to quantify 105 lipoprotein subclasses and 24 low molecular weight metabolites from the nuclear magnetic resonance, NMR, spectra. For all spectrometers, the instrument specific variance in measuring internal quality controls, QCs, was lower than the percentage described by the National Cholesterol Education Program, NCEP, criteria for lipid testing (triglycerides<2.7%, cholesterol<2.8%; LDL-cholesterol<2.8%; HDL-cholesterol<2.3%), showing exceptional reproducibility for direct quantitation of lipoproteins in both matrices. The average RSD for the 105 lipoprotein parameters in the 11 instruments was 4.6% and 3.9% for the two NIST samples while it was 38% and 40% for the 37 commercially sourced plasmas and sera, respectively, showing negligible analytical compared to biological variation. The coefficient of variance, CV, obtained for the quantification of the small molecules across the 11 spectrometers was below 15% for 20 out of the 24 metabolites analyzed. This study provides further evidence of the suitability of NMR for high-throughput lipoprotein subcomponent analysis and small molecule quantitation with the exceptional reproducibility required for clinical and other regulatory settings

    Introduction to the functional RG and applications to gauge theories

    Get PDF
    These lectures contain an introduction to modern renormalization group (RG) methods as well as functional RG approaches to gauge theories. In the first lecture, the functional renormalization group is introduced with a focus on the flow equation for the effective average action. The second lecture is devoted to a discussion of flow equations and symmetries in general, and flow equations and gauge symmetries in particular. The third lecture deals with the flow equation in the background formalism which is particularly convenient for analytical computations of truncated flows. The fourth lecture concentrates on the transition from microscopic to macroscopic degrees of freedom; even though this is discussed here in the language and the context of QCD, the developed formalism is much more general and will be useful also for other systems.Comment: 60 pages, 14 figures, Lectures held at the 2006 ECT* School "Renormalization Group and Effective Field Theory Approaches to Many-Body Systems", Trento, Ital

    Body mass index has a curvilinear relationship with the percentage of body fat among children

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>Body Mass Index (BMI), which is defined as the ratio between weight (in kg) and height (in m<sup>2</sup>), is often used in clinical practice as well as in large scale epidemiological studies to classify subjects as underweight, normal weight, overweight or obese. Although BMI does not directly measure the percentage of Body Fat (BF%), it is widely applied because it is strongly related with BF%, it is easy to measure and it is an important predictor of mortality. Among children, age and sex-specific reference values of BMI, known as percentiles, are used. However, it is not clear how strong the relationship between BMI and BF% is among children and whether the association is linear. We performed a cross-sectional study aiming at evaluating the strength and shape of the relationship between BMI and BF% among school-aged children aged 6-12 years.</p> <p>Findings</p> <p>The study was conducted on a sample of 361 football-playing male children aged 6 to 12 years in Rome, Italy. Age, weight, height and skinfold thickness were collected. BF% was estimated using 4 skinfold equations whereas BMI was converted into BMI-for-age z-score. The relationship between these variables was examined using linear regression analyses. Mean BMI was 18.2 (± 2.8), whereas BF% was influenced by the skinfold equation used, with mean values ranging from 15.6% to 23.0%. A curvilinear relationship between BMI-for-age zscore and BF % was found, with the regression line being convex. The association between BMI-for-age zscore and BF% was stronger among overweight/obese children than among normal/underweight children. This curvilinear pattern was evident in all 4 skinfold equations used.</p> <p>Conclusions</p> <p>The association between BMI-for-age zscore and BF% is not linear among male children aged 6-12 years and it is stronger among overweight and obese subjects than among normal and underweight subjects. In this age group, BMI is a valid index of adiposity only among overweight and obese subjects.</p

    Circulating Cell-Free DNA in Dogs with Mammary Tumors: Short and Long Fragments and Integrity Index

    Get PDF
    Circulating cell-free DNA (cfDNA) has been considered an interesting diagnostic/prognostic plasma biomarker in tumor-bearing subjects. In cancer patients, cfDNA can hypothetically derive from tumor necrosis/apoptosis, lysed circulating cells, and some yet unrevealed mechanisms of active release. This study aimed to preliminarily analyze cfDNA in dogs with canine mammary tumors (CMTs). Forty-four neoplastic, 17 non-neoplastic disease-bearing, and 15 healthy dogs were recruited. Necrosis and apoptosis were also assessed as potential source of cfDNA on 78 CMTs diagnosed from the 44 dogs. The cfDNA fragments and integrity index significantly differentiated neoplastic versus non-neoplastic dogs (P<0.05), and allowed the distinction between benign and malignant lesions (P<0.05). Even if without statistical significance, the amount of cfDNA was also affected by tumor necrosis and correlated with tumor size and apoptotic markers expression. A significant (P<0.01) increase of Bcl-2 in malignant tumors was observed, and in metastatic CMTs the evasion of apoptosis was also suggested. This study, therefore, provides evidence that cfDNA could be a diagnostic marker in dogs carrying mammary nodules suggesting that its potential application in early diagnostic procedures should be further investigated

    Biological effects of exposure to magnetic resonance imaging: an overview

    Get PDF
    The literature on biological effects of magnetic and electromagnetic fields commonly utilized in magnetic resonance imaging systems is surveyed here. After an introduction on the basic principles of magnetic resonance imaging and the electric and magnetic properties of biological tissues, the basic phenomena to understand the bio-effects are described in classical terms. Values of field strengths and frequencies commonly utilized in these diagnostic systems are reported in order to allow the integration of the specific literature on the bio-effects produced by magnetic resonance systems with the vast literature concerning the bio-effects produced by electromagnetic fields. This work gives an overview of the findings about the safety concerns of exposure to static magnetic fields, radio-frequency fields, and time varying magnetic field gradients, focusing primarily on the physics of the interactions between these electromagnetic fields and biological matter. The scientific literature is summarized, integrated, and critically analyzed with the help of authoritative reviews by recognized experts, international safety guidelines are also cited

    Optical Magnetometry

    Get PDF
    Some of the most sensitive methods of measuring magnetic fields utilize interactions of resonant light with atomic vapor. Recent developments in this vibrant field are improving magnetometers in many traditional areas such as measurement of geomagnetic anomalies and magnetic fields in space, and are opening the door to new ones, including, dynamical measurements of bio-magnetic fields, detection of nuclear magnetic resonance (NMR), magnetic-resonance imaging (MRI), inertial-rotation sensing, magnetic microscopy with cold atoms, and tests of fundamental symmetries of Nature.Comment: 11 pages; 4 figures; submitted to Nature Physic
    corecore