20 research outputs found

    Technical pitfalls and proposed modifications of instructions for use for endovascular aortic aneurysm repair using the Gore Excluder conformable device in angulated and short landing zones

    Get PDF
    We describe a case of an abdominal aortic aneurysm (AAA) and angulated proximal neck treated with a Gore Excluder conformable endoprosthesis and show relevant technical pitfalls in the deployment of the graft main body. An 82-year-old man presented with a 71-mm asymptomatic AAA with an angulated infrarenal proximal neck (75°) and was referred to our unit. The patient was treated with a 26-mm Gore Excluder conformable device, which was deployed slightly above the renal arteries after precatheterization of the lowest renal artery. The graft was then repositioned with support of the introducer sheath and a stiff guide wire. The proximal sealing zone was ballooned before the endograft delivery system was retrieved to avoid distal migration. Technical success was achieved. The patient was discharged with no complications. No type Ia endoleak was present on the 6-month computed tomography scan. Endovascular treatment of an AAA with a severe angulated proximal neck can be effective with a conformable stent graft if technical measures are used during deployment of the main body to optimize the seal.</p

    Midterm Outcomes and Aneurysm Sac Dynamics Following Fenestrated Endovascular Aneurysm Repair after Previous Endovascular Aneurysm Repair

    Get PDF
    Objective: Fenestrated endovascular aneurysm repair (FEVAR) is a feasible option for aortic repair after endovascular aneurysm repair (EVAR), due to improved peri-operative outcomes compared with open conversion. However, little is known regarding the durability of FEVAR as a treatment for failed EVAR. Since aneurysm sac evolution is an important marker for success after aneurysm repair, the aim of the study was to examine midterm outcomes and aneurysm sac dynamics of FEVAR after prior EVAR. Methods:Patients undergoing FEVAR for complex abdominal aortic aneurysms from 2008 to 2021 at two hospitals in The Netherlands were included. Patients were categorised into primary FEVAR and FEVAR after EVAR. Outcomes included five year mortality rate, one year aneurysm sac dynamics (regression, stable, expansion), sac dynamics over time, and five year aortic related procedures. Analyses were done using Kaplan–Meier methods, multivariable Cox regression analysis, chi square tests, and linear mixed effect models. Results: One hundred and ninety-six patients with FEVAR were identified, of whom 27% (n = 53) had had a prior EVAR. Patients with prior EVAR were significantly older (78 ± 6.7 years vs. 73 ± 5.9 years, p &lt; .001). There were no significant differences in mortality rate. FEVAR after EVAR was associated with a higher risk of aortic related procedures within five years (hazard ratio [HR] 2.6; 95% confidence interval [CI] 1.1 – 6.5, p = .037). Sac dynamics were assessed in 154 patients with available imaging. Patients with a prior EVAR showed lower rates of sac regression and higher rates of sac expansion at one year compared with primary FEVAR (sac expansion 48%, n = 21/44, vs. 8%, n = 9/110, p &lt; .001). Sac dynamics over time showed similar results, sac growth for FEVAR after EVAR, and sac shrinkage for primary FEVAR (p &lt; .001). Conclusion: There were high rates of sac expansion and a need for more secondary procedures in FEVAR after EVAR than primary FEVAR patients, although this did not affect midterm survival. Future studies will have to assess whether FEVAR after EVAR is a valid intervention, and the underlying process that drives aneurysm sac growth following successful FEVAR after EVAR.</p

    Molecular interactions involved in the transactivation of the human T-cell leukemia virus type 1 promoter mediated by Tax and CREB-2 (ATF-4).

    Get PDF
    The human T-cell leukemia virus type 1 (HTLV-1) Tax protein activates viral transcription through three 21-bp repeats located in the U3 region of the HTLV-1 long terminal repeat and called Tax-responsive elements (TxREs). Each TxRE contains nucleotide sequences corresponding to imperfect cyclic AMP response elements (CRE). In this study, we demonstrate that the bZIP transcriptional factor CREB-2 is able to bind in vitro to the TxREs and that CREB-2 binding to each of the 21-bp motifs is enhanced by Tax. We also demonstrate that Tax can weakly interact with CREB-2 bound to a cellular palindromic CRE motif such as that found in the somatostatin promoter. Mutagenesis of Tax and CREB-2 demonstrates that both N- and C-terminal domains of Tax and the C-terminal region of CREB-2 are required for direct interaction between the two proteins. In addition, the Tax mutant M47, defective for HTLV-1 activation, is unable to form in vitro a ternary complex with CREB-2 and TxRE. In agreement with recent results suggesting that Tax can recruit the coactivator CREB-binding protein (CBP) on the HTLV-1 promoter, we provide evidence that Tax, CREB-2, and CBP are capable of cooperating to stimulate viral transcription. Taken together, our data highlight the major role played by CREB-2 in Tax-mediated transactivation

    Nuclear localization of HTLV-I bZIP factor (HBZ) is mediated by three distinct motifs.

    Get PDF
    Contains fulltext : 48999thebault.pdf (publisher's version ) (Open Access)The genome of the human T-cell leukemia virus type I (HTLV-I) codes for a basic leucine zipper protein, HBZ, capable of repressing JUN activity and viral transcription. Transient expression in mammalian cells showed that HBZ was targeted to the nucleus, where it accumulated in nuclear speckles. By using a complementary set of deletion mutants, we report here that the nuclear targeting of HBZ is mediated by three distinct nuclear localization signals and that at least two are necessary for the translocation of HBZ to the nucleus. Moreover, the resulting mutant proteins distribute throughout the nucleoplasm and/or into the nucleoli, whereas the wild-type HBZ exclusively accumulates in nuclear speckles, suggesting that the integrity of the protein is required for its speckle localization. We also demonstrate that the HBZ-containing speckles do not correspond to Cajal bodies, splicing factor compartments, or promyelocytic leukemia oncoprotein bodies. Unexpectedly, by using immunogold electron microscopy, we found HBZ localized to heterochromatin. Until now, such characteristics had never been described for a transcription factor and could explain the inhibitory activity of HBZ

    Intraoperative complications during standard and complex endovascular aortic repair

    No full text
    This study aimed to provide a comprehensive overview of the most common intraoperative adverse events that occur during standard endovascular repair and fenestrated-branched endovascular repair to treat abdominal aortic aneurysms, thoracoabdominal aortic aneurysms, and aortic arch aneurysms. Despite advancements in endovascular techniques, sophisticated imaging and improved graft designs, intraoperative difficulties still occur, even in highly standardized procedures and high-volume centers. This study emphasized that with the increased adoption and complexity of endovascular aortic procedures, strategies to minimize intraoperative adverse events should be protocolized and standardized. There is a need for robust evidence on this topic, which could potentially optimize treatment outcomes and durability of the available techniques

    How We Would Treat Our Own Thoracoabdominal Aortic Aneurysm

    No full text
    This manuscript is intended to provide a comprehensive review of the current state of knowledge on endovascular repair of thoracoabdominal aortic aneurysms (TAAAs). The management of these complex aneurysms requires an interdisciplinary and patient-specific approach in high-volume centers. An index case is used to discuss the diagnosis and treatment of a patient undergoing fenestrated-branched endovascular aneurysm repair for a TAAA.</p
    corecore