12 research outputs found

    Constraints on the Nucleon Strange Form Factors at Q^2 ~ 0.1 GeV^2

    Get PDF
    We report the most precise measurement to date of a parity-violating asymmetry in elastic electron-proton scattering. The measurement was carried out with a beam energy of 3.03 GeV and a scattering angle =6 degrees, with the result A_PV = -1.14 +/- 0.24 (stat) +/- 0.06 (syst) parts per million. From this we extract, at Q^2 = 0.099 GeV^2, the strange form factor combination G_E^s + 0.080 G_M^s = 0.030 +/- 0.025 (stat) +/- 0.006 (syst) +/- 0.012 (FF) where the first two errors are experimental and the last error is due to the uncertainty in the neutron electromagnetic form factor. This result significantly improves current knowledge of G_E^s and G_M^s at Q^2 ~0.1 GeV^2. A consistent picture emerges when several measurements at about the same Q^2 value are combined: G_E^s is consistent with zero while G_M^s prefers positive values though G_E^s=G_M^s=0 is compatible with the data at 95% C.L.Comment: minor wording changes for clarity, updated references, dropped one figure to improve focu

    Serum levels of matrix metalloproteinase-10 are associated with the severity of atherosclerosis in patients with chronic kidney disease

    No full text
    Cardiovascular disease is the leading cause of mortality in chronic kidney disease (CKD). As matrix metalloproteinases have a major role in atherosclerosis, we hypothesized that alterations in metalloproteinases-8, -10 and their tissue inhibitor-1 can be associated with the severity of atherosclerosis in patients with kidney disease. This was evaluated in a cross-sectional, observational study of 111 patients with stages I-V kidney disease, 217 patients on dialysis and 50 healthy controls. The severity of atherosclerosis was estimated with the atherosclerosis score (AS), combining the results of ankle-brachial index and carotid ultrasound. Serum levels of the two metalloproteinases and tissue inhibitor-1 were measured by enzyme-linked immunosorbent assay and were significantly increased in patients with kidney disease compared with the healthy controls, and higher in patients on dialysis than in earlier stages of CKD. The severity of the AS was also more prevalent in the dialysis group, in which serum levels of both metalloproteinases and tissue inhibitor-1 were significantly higher. After multivariate analysis, metalloproteinase-10, dialysis, C-reactive protein, age, and male gender were associated with increased risk of atherosclerosis. Thus, patients with CKD exhibit elevated levels of circulating metalloproteinase-10, and this was independently associated with the severity of atherosclerosis and may represent a new biomarker of atherosclerotic diseases

    Serum levels of matrix metalloproteinase-10 are associated with the severity of atherosclerosis in patients with chronic kidney disease

    No full text
    Cardiovascular disease is the leading cause of mortality in chronic kidney disease (CKD). As matrix metalloproteinases have a major role in atherosclerosis, we hypothesized that alterations in metalloproteinases-8, -10 and their tissue inhibitor-1 can be associated with the severity of atherosclerosis in patients with kidney disease. This was evaluated in a cross-sectional, observational study of 111 patients with stages I-V kidney disease, 217 patients on dialysis and 50 healthy controls. The severity of atherosclerosis was estimated with the atherosclerosis score (AS), combining the results of ankle-brachial index and carotid ultrasound. Serum levels of the two metalloproteinases and tissue inhibitor-1 were measured by enzyme-linked immunosorbent assay and were significantly increased in patients with kidney disease compared with the healthy controls, and higher in patients on dialysis than in earlier stages of CKD. The severity of the AS was also more prevalent in the dialysis group, in which serum levels of both metalloproteinases and tissue inhibitor-1 were significantly higher. After multivariate analysis, metalloproteinase-10, dialysis, C-reactive protein, age, and male gender were associated with increased risk of atherosclerosis. Thus, patients with CKD exhibit elevated levels of circulating metalloproteinase-10, and this was independently associated with the severity of atherosclerosis and may represent a new biomarker of atherosclerotic diseases

    Measurement of the 3He spin-structure functions and of neutron (3He) spin-dependent sum rules at 0.035 ≤ Q2 ≤ 0.24 GeV2

    No full text
    International audienceThe spin-structure functions g1 and g2, and the spin-dependent partial cross-section σTT have been extracted from the polarized cross-sections differences, Δσ∥(ν,Q2) and Δσ⊥(ν,Q2) measured for the He3→(e→,e′)X reaction, in the E97-110 experiment at Jefferson Lab. Polarized electrons with energies from 1.147 to 4.404 GeV were scattered at angles of 6∘ and 9∘ from a longitudinally or transversely polarized 3He target. The data cover the kinematic regions of the quasi-elastic, resonance production and beyond. From the extracted spin-structure functions, the first moments Γ1‾(Q2), Γ2(Q2) and ITT(Q2) are evaluated with high precision for the neutron in the Q2 range from 0.035 to 0.24GeV2. The comparison of the data and the chiral effective field theory predictions reveals the importance of proper treatment of the Δ degree of freedom for spin observables
    corecore