3 research outputs found

    Performance Analysis of CFRP Composite Strips Confined RC Columns under Axial Compression

    Get PDF
    In an attempt to mitigate the high cost of FRP composite strengthening, an experimental investigation was carried out that sought to achieve efficient and most favorable FRP strengthening using CFRP composite strips. 50 mm wide CFRP composite strips were used in two different spacings (20 mm and 40 mm) to confine columns. The test results of the column confined with smaller spacing (20 mm) showed significant restraint of axial deformation of the column and enhanced the strength capacity to a maximum of 99.20% compared to that of reference column. In contrast, the column confined by strips with larger spacing (40 mm) failed by crushing of concrete alone, which occurred even before the CFRP strips reached their ultimate strain. In addition, the embodied energy that exists in the CFRP strips could not be utilized effectively. The stress and strength enhancement ratio of this present study was compared with the previous research that has been conducted on columns confined with full wrapping. From the obtained results, it is recommended that CFRP strips with a spacing of 20 mm be used to improve the strength capacity of the RC column; in addition, this wrapping technique provides economic benefits compared to a column confined with full wrapping

    Feasibility Studies on the Removal of Iron and Fluoride from Aqueous Solution using Shells of Limonia Acidissma as Adsorbent

    Get PDF
    1226-1229Experimental studies were carried out to remove the contaminants particularly iron and fluoride and to study the efficiency of the removal of fluoride using Limonia Acidissma (Bael fruit) shell. Accordingly a set of experiments have been conducted using batch and column processes, with the help of activated carbon prepared from the shell of Limonia Acidissma. Experiments reveal that the adsorption capacity of the shell of Limonia Acidissma is significant as 64% to yield promising solutions

    Effects of Concentrical Partial (Local) Compression on the Structural Behavior of Concrete Filled Steel Tubular Column

    Get PDF
    The objective of this present paper is to investigate the structural behavior of square and circular Concrete Filled Steel Tubular (CFST) stub columns subjected to axial partial/local compression. The experimental parameters were local compression area and section type. Among the twelve specimens, six specimens were tested under full compression and the remaining six specimens were tested under local compression. The experimental observation indicated that the failure pattern of the CFST column with partial compression is fairly different from the CFST column subjected to full compression. The confinement provided by the circular section is quite different than the confinement provided by the square section, when the CFST column is subjected to axially local compression. It was found that the elastic modulus (stiffness) and the ultimate bearing capacity of the CFST column decreased with the increase in local compression ratio. The circular and square CFST columns subjected to partial/local compression achieved an ultimate strength of 4.45% and 14.15%, respectively, less than that of the columns subjected to full compression. From the above observation, it can be inferred that the structural performance of the CFST column is significantly influenced by the local area compression ratio and this effect should be taken into account in design models
    corecore