7,596 research outputs found
Long-Range Exciton Diffusion in Two-Dimensional Assemblies of Cesium Lead Bromide Perovskite Nanocrystals
F\"orster Resonant Energy Transfer (FRET)-mediated exciton diffusion through
artificial nanoscale building block assemblies could be used as a new
optoelectronic design element to transport energy. However, so far nanocrystal
(NC) systems supported only diffusion length of 30 nm, which are too small to
be useful in devices. Here, we demonstrate a FRET-mediated exciton diffusion
length of 200 nm with 0.5 cm2/s diffusivity through an ordered, two-dimensional
assembly of cesium lead bromide perovskite nanocrystals (PNC). Exciton
diffusion was directly measured via steady-state and time-resolved
photoluminescence (PL) microscopy, with physical modeling providing deeper
insight into the transport process. This exceptionally efficient exciton
transport is facilitated by PNCs high PL quantum yield, large absorption
cross-section, and high polarizability, together with minimal energetic and
geometric disorder of the assembly. This FRET-mediated exciton diffusion length
matches perovskites optical absorption depth, opening the possibility to design
new optoelectronic device architectures with improved performances, and
providing insight into the high conversion efficiencies of PNC-based
optoelectronic devices
A New Scintillator Tile/Fiber Preshower Detector for the CDF Central Calorimeter
A detector designed to measure early particle showers has been installed in
front of the central CDF calorimeter at the Tevatron. This new preshower
detector is based on scintillator tiles coupled to wavelength-shifting fibers
read out by multi-anode photomultipliers and has a total of 3,072 readout
channels. The replacement of the old gas detector was required due to an
expected increase in instantaneous luminosity of the Tevatron collider in the
next few years. Calorimeter coverage, jet energy resolution, and electron and
photon identification are among the expected improvements. The final detector
design, together with the R&D studies that led to the choice of scintillator
and fiber, mechanical assembly, and quality control are presented. The detector
was installed in the fall 2004 Tevatron shutdown and started collecting
colliding beam data by the end of the same year. First measurements indicate a
light yield of 12 photoelectrons/MIP, a more than two-fold increase over the
design goals.Comment: 5 pages, 10 figures (changes are minor; this is the final version
published in IEEE-Trans.Nucl.Sci.
Three-Body Dynamics and Self-Powering of an Electrodynamic Tether in a Plasmasphere
The dynamics of an electrodynamic tether in a three-body gravitational environment are investigated. In the classical two-body scenario the extraction of power is at the expense of orbital kinetic energy. As a result of power extraction, an electrodynamic tether satellite system loses altitude and deorbits. This concept has been proposed and well investigated in the past, for example for orbital debris mitigation and spent stages reentry. On the other hand, in the three-body scenario an electrodynamic tether can be placed in an equilibrium position fixed with respect to the two primary bodies without deorbiting, and at the same time generate power for onboard use. The appearance of new equilibrium positions in the perturbed three-body problem allow this to happen as the electrical power is extracted at the expenses of the plasma corotating with the primary body. Fundamental differences between the classical twobody dynamics and the new phenomena appearing in the circular restricted three-body problem perturbed by the electrodynamic force of the electrodynamic tether are shown in the paper. An interesting application of an electrodynamic tether placed in the Jupiter plasma torus is then considered, in which the electrodynamic tether generates useful electrical power of about 1 kW with a 20-km-long electrodynamic tether from the environmental plasma without losing orbital energy
Quartz Plate Calorimeter as SLHC Upgrade to CMS Hadronic EndCap Calorimeters
Due to an expected increase in radiation damage under super-LHC conditions, we propose to substitute the scintillator tiles in the original design of the hadronic endcap (HE) calorimeter with quartz plates. Quartz is proved to be radiation hard by the radiation damage tests with electron, proton, neutron and gamma beams. Using wavelength shifting fibers, it is possible to collect efficiently the Cherenkov light generated in quartz plates. This paper summarizes the results from various test beams, bench tests, and Geant4 simulations done on methods of collecting light from quartz plates, as well as radiation hardness tests on quartz material
Measurement of Charged Pion Production Yields off the NuMI Target
The fixed-target MIPP experiment, Fermilab E907, was designed to measure the
production of hadrons from the collisions of hadrons of momenta ranging from 5
to 120 GeV/c on a variety of nuclei. These data will generally improve the
simulation of particle detectors and predictions of particle beam fluxes at
accelerators. The spectrometer momentum resolution is between 3 and 4%, and
particle identification is performed for particles ranging between 0.3 and 80
GeV/c using , time-of-flight and Cherenkov radiation measurements. MIPP
collected events of 120 GeV Main Injector protons striking a
target used in the NuMI facility at Fermilab. The data have been analyzed and
we present here charged pion yields per proton-on-target determined in bins of
longitudinal and transverse momentum between 0.5 and 80 GeV/c, with combined
statistical and systematic relative uncertainties between 5 and 10%.Comment: 15 pages, 13 figure
Spin-Splitter Studies: Polarization Stability Measurements at IUCF
This research was sponsored by the National Science Foundation Grant NSF PHY-931478
Plasmodium subtilisin-like protease 1 (SUB1): insights into the active-site structure, specificity and function of a pan-malaria drug target.
Release of the malaria merozoite from its host erythrocyte (egress) and invasion of a fresh cell are crucial steps in the life cycle of the malaria pathogen. Subtilisin-like protease 1 (SUB1) is a parasite serine protease implicated in both processes. In the most dangerous human malarial species, Plasmodium falciparum, SUB1 has previously been shown to have several parasite-derived substrates, proteolytic cleavage of which is important both for egress and maturation of the merozoite surface to enable invasion. Here we have used molecular modelling, existing knowledge of SUB1 substrates, and recombinant expression and characterisation of additional Plasmodium SUB1 orthologues, to examine the active site architecture and substrate specificity of P. falciparum SUB1 and its orthologues from the two other major human malaria pathogens Plasmodium vivax and Plasmodium knowlesi, as well as from the rodent malaria species, Plasmodium berghei. Our results reveal a number of unusual features of the SUB1 substrate binding cleft, including a requirement to interact with both prime and non-prime side residues of the substrate recognition motif. Cleavage of conserved parasite substrates is mediated by SUB1 in all parasite species examined, and the importance of this is supported by evidence for species-specific co-evolution of protease and substrates. Two peptidyl alpha-ketoamides based on an authentic PfSUB1 substrate inhibit all SUB1 orthologues examined, with inhibitory potency enhanced by the presence of a carboxyl moiety designed to introduce prime side interactions with the protease. Our findings demonstrate that it should be possible to develop 'pan-reactive' drug-like compounds that inhibit SUB1 in all three major human malaria pathogens, enabling production of broad-spectrum antimalarial drugs targeting SUB1
Design and construction of new central and forward muon counters for CDF II
New scintillation counters have been designed and constructed for the CDF
upgrade in order to complete the muon coverage of the central CDF detector, and
to extend this coverage to larger pseudorapidity. A novel light collection
technique using wavelength shifting fibers, together with high quality
polystyrene-based scintillator resulted in compact counters with good and
stable light collection efficiency over lengths extending up to 320 cm. Their
design and construction is described and results of their initial performance
are reported.Comment: 20 pages, 15 figure
- …