Contact force sensing in ablation of ventricular arrhythmias using a 56-hole open-irrigation catheter: a propensity-matched analysis.
PURPOSE: The effect of adding contact force (CF) sensing to 56-hole tip irrigation in ventricular arrhythmia (VA) ablation has not been previously studied. We aimed to compare outcomes with and without CF sensing in VA ablation using a 56-hole radiofrequency (RF) catheter. METHODS: A total of 164 patients who underwent first-time VA ablation using Thermocool SmartTouch Surround Flow (TC-STSF) catheter (Biosense-Webster, Diamond Bar, CA, USA) were propensity-matched in a 1:1 fashion to 164 patients who had first-time ablation using Thermocool Surround Flow (TC-SF) catheter. Patients were matched for age, gender, cardiac aetiology, ejection fraction and approach. Acute success, complications and long-term follow-up were compared. RESULTS: There was no difference between procedures utilising either TC-SF or TC-STSF in acute success (TC-SF: 134/164 (82%), TC-STSF: 141/164 (86%), p = 0.3), complications (TC-SF: 11/164 (6.7%), TC-STSF: 11/164 (6.7%), p = 1.0) or VA-free survival (TC-SF: mean arrhythmia-free survival time = 5.9 years, 95% CI = 5.4-6.4, TC-STSF: mean = 3.2 years, 95% CI = 3-3.5, log-rank p = 0.74). Fluoroscopy time was longer in normal hearts with TC-SF (19 min, IQR: 14-30) than TC-STSF (14 min, IQR: 8-25; p = 0.04). CONCLUSION: Both TC-SF and TC-STSF catheters are safe and effective in treating VAs. The use of CF sensing catheters did not improve safety or acute and long-term outcomes, but reduced fluoroscopy time in normal heart VA
Repeat Ablation for Atrial Fibrillation Recurrence Post Cryoballoon or Radiofrequency Ablation in the FIRE and ICE Trial
Background: The FIRE AND ICE trial assessed efficacy and safety of pulmonary vein (PV) isolation using cryoballoon versus radiofrequency current (RFC) ablation in patients with drug refractory, symptomatic, paroxysmal atrial fibrillation (AF). The purpose of the current study was to assess index lesion durability as well as reablation strategy and outcomes in trial patients undergoing a reablation procedure. Methods: Patients with reablation procedures during FIRE AND ICE were retrospectively consented and enrolled at 13 trial centers. The first reablation for each patient was included in the analysis. Documented arrhythmias before reablation, number and location of reconnected PVs, lesions created during reablations, procedural characteristics, and acute as well as long-term outcomes were assessed. Results: Eighty-nine (36 cryoballoon and 53 RFC) patients were included in this study. Paroxysmal atrial fibrillation was the predominant recurrent arrhythmia (69%) before reablation. Reablations occurred at a median of 173 and 182 days (P=0.54) in the cryoballoon and RFC cohorts, respectively. The number of reconnected PVs was significantly higher in the RFC than the cryoballoon group (2.1\ub11.4 versus 1.4\ub11.1; P=0.010), which was driven by significantly more reconnected left superior PVs and markedly more reconnected right superior PVs. The number of (predominantly RFC) lesions applied during reablation was significantly greater in patients originally treated with RFC (3.3\ub11.3 versus 2.5\ub11.5; P=0.015) with no difference in overall acute success (P=0.70). After reablation, no differences in procedure-related rehospitalization or antiarrhythmic drug utilization were observed between cohorts. Conclusions: At reablation, patients originally treated with the cryoballoon had significantly fewer reconnected PVs, which may reflect RFC catheter instability in certain left atrial regions, and thus required fewer lesions for reablation success. Repeat ablations were predominantly performed with RFC and resulted in similar acute success, duration of hospitalization, and antiarrhythmic drug prescription between the study cohorts. Clinical Trial Registration: URL: https://www.clinicaltrials.gov. Unique identifier: NCT03314753
More Legal Transformations for Locality
Distinguished paper award Commercial link : http://www.springerlink.de ALCHEMY/http://www.springer.comProgram transformations are one of the most valuable compiler techniques to improve data locality. However, restructuring compilers have a hard time coping with data dependences. A typical solution is to focus on program parts where the dependences are simple enough to enable any transformation. For more complex problems is only addressed the question of checking whether a transformation is legal or not. In this paper we propose to go further. Starting from a transformation with no guarantee on legality, we show how we can correct it for dependence satisfaction with no consequence on its locality properties. Generating code having the best locality is a direct application of this result
Impact of Female Sex on Clinical Outcomes in the FIRE AND ICE Trial of Catheter Ablation for Atrial Fibrillation
BACKGROUND: Data on predictors of long-term clinical outcomes after catheter ablation of atrial fibrillation (AF) are limited. We sought to assess the association of baseline covariates with clinical outcomes in the 750 patients with drug-refractory paroxysmal AF enrolled in FIRE AND ICE. METHODS: In a 2-part analysis, univariate and multivariable Cox regression models were first used to identify baseline patient characteristics predictive of catheter ablation efficacy determined by the clinical end points of (1) atrial arrhythmia recurrence (primary efficacy failure), (2) cardiovascular rehospitalization, and (3) repeat ablation. Propensity score stratification methods were then used to account for differences in baseline characteristics between sexes.
RESULTS: Female sex (hazard ratio [HR], 1.37; 95% confidence interval [CI], 1.08-1.73; P=0.010) and prior direct current cardioversion (HR, 1.40; 95% CI, 1.07-1.82; P=0.013) were independently associated with atrial arrhythmia recurrence. Female sex (HR, 1.36; 95% CI, 1.02-1.80; P=0.035) and hypertension (HR, 1.48; 95% CI, 1.09-2.00; P=0.013) independently predicted cardiovascular rehospitalization. A longer history of AF (HR, 1.03; 95% CI, 1.00-1.06; P=0.039) increased the rate of repeat ablation. Women continued to have higher rates of primary efficacy failure and cardiovascular rehospitalization after propensity score adjustment, with adjusted HRs of 1.51 (95% CI, 1.16-2.18; P<0.05) and 1.40 (95% CI, 1.15-2.17; P<0.05), respectively.
CONCLUSIONS: After catheter ablation of paroxysmal AF, female sex was associated with an almost 40% increase in the risks of primary efficacy failure and cardiovascular rehospitalization. Primary efficacy failure was also adversely impacted by a history of direct current cardioversion, whereas hypertension had a negative impact on cardiovascular rehospitalization. History of AF was the only predictor of repeat ablation
Modularity for Large Virtual Reality Applications
International audienceThis paper focuses on the design of high performance VR applications. These applications usually involve various I/O devices and complex simulations. A parallel architecture or grid infrastructure is required to provide the necessary I/O and processing capabilities. Developing such applications faces several difficulties, two important ones being software engineering and performance issues. We argue that application modularity is a key concept to help the developer handle the complexity of these applications. We discuss how various approaches borrowed from other existing works can be combined to significantly improve the modularity of VR applications. This led to the development of the FlowVR middleware that associates a data-flow model with a hierarchical component model. Different case studies are presented to discuss the benefits of the approach proposed
The Impact of Cryoballoon Versus Radiofrequency Ablation for Paroxysmal Atrial Fibrillation on Healthcare Utilization and Costs: An Economic Analysis From the FIRE AND ICE Trial
BACKGROUND: This study sought to assess payer costs following cryoballoon or radiofrequency current (RFC) catheter ablation of paroxysmal atrial fibrillation in the randomized FIRE AND ICE trial. METHODS AND RESULTS: A trial period analysis of healthcare costs evaluated the impact of ablation modality (cryoballoon versus RFC) on differences in resource use and associated payer costs. Analyses were based on repeat interventions, rehospitalizations, and cardioversions during the trial, with unit costs based on 3 national healthcare systems (Germany [euro], the United Kingdom [ pound], and the United States [925 in favor of cryoballoon ablation (P=0.012, 0.013, and 0.016, respectively). This resulted in trial period total cost savings of euro245 000, pound140 000, and $355 000. CONCLUSIONS: When compared with RFC ablation, cryoballoon ablation was associated with a reduction in resource use and payer costs. In all 3 national healthcare systems analyzed, this reduction resulted in substantial trial period cost savings, primarily attributable to fewer repeat ablations and a reduction in cardiovascular rehospitalizations with cryoballoon ablation. CLINICAL TRIAL REGISTRATION: URL: http://www.clinicaltrials.gov. Identifier: NCT01490814
- …