240 research outputs found

    Tailoring the interfacial interactions in ferroelectric fluorinated polymer/ceramic nanocomposites

    Get PDF
    In this work composites of PVDF-TrFE containing 60 vol% untreated and surface modified BaTiO3 were produced by solvent casting with two procedures. Their morphology and structure were characterized by scanning electron microscope, X-ray diffraction and differential scanning calorimetry. The effect of the processing conditions and of the surface modification of BaTiO3 on the viscoelastic, dielectric and piezoelectric properties was investigated. The surface modification of BaTiO3 allowed obtaining composite films with low porosity and good filler dispersion, and hence higher storage modulus and lower loss tangent, in a wider processing window. Furthermore it reduced the dielectric losses at low frequency and modified the decay kinetic of the d33 piezoelectric coefficient with respect to composites made with untreated particles

    Nonlinear Elasticity in Biological Gels

    Full text link
    Unlike most synthetic materials, biological materials often stiffen as they are deformed. This nonlinear elastic response, critical for the physiological function of some tissues, has been documented since at least the 19th century, but the molecular structure and the design principles responsible for it are unknown. Current models for this response require geometrically complex ordered structures unique to each material. In this Article we show that a much simpler molecular theory accounts for strain stiffening in a wide range of molecularly distinct biopolymer gels formed from purified cytoskeletal and extracellular proteins. This theory shows that systems of semi-flexible chains such as filamentous proteins arranged in an open crosslinked meshwork invariably stiffen at low strains without the need for a specific architecture or multiple elements with different intrinsic stiffnesses.Comment: 23 pages, 5 figures, submitted to Natur

    Elongation and fluctuations of semi-flexible polymers in a nematic solvent

    Get PDF
    We directly visualize single polymers with persistence lengths ranging from ℓp=0.05\ell_p=0.05 to 16 ÎŒ\mum, dissolved in the nematic phase of rod-like {\it fd} virus. Polymers with sufficiently large persistence length undergo a coil-rod transition at the isotropic-nematic transition of the background solvent. We quantitatively analyze the transverse fluctuations of semi-flexible polymers and show that at long wavelengths they are driven by the fluctuating nematic background. We extract both the Odijk deflection length and the elastic constant of the background nematic phase from the data.Comment: 4 pages, 4 figures, submitted to PR

    Frequency dependent dielectric and mechanical behaviour of elastomers for actuator applications

    Get PDF
    The low frequency mechanical and dielectric behavior of three different elastomers has been investigated by dynamic mechanical analysis and dielectric spectroscopy, with the aim of accounting for the frequency dependence of the characteristics of the corresponding dielectric elastomer actuators. Satisfactory agreement was obtained between the dynamic response of the actuators and a simple model based on the experimental data for the elastomers, assuming that the relatively large prestrains employed in the actuators to have little influence on the frequency dependence of their effective moduli. It was thus demonstrated that the frequency dependence of the actuator strain is dominated by that of the mechanical response of the elastomer, and that the frequency dependence of the dielectric properties has a relatively minor influence on the actuator performance

    Mechanical failure analysis of thin film transistor devices on steel and polyimide substrates for flexible display applications

    Get PDF
    The crack onset strain (COS) of 4-level thin film transistor (TFT) devices on both steel foils and thin polyimide (PI) films was investigated using tensile experiments carried out in situ in an optical microscope. Cracks initiated first within the SiO2 insulator layer for both types of substrates. The COS was found to be equal to 1.15% and 0.24% for steel and PI, respectively. The influence of loading direction on failure of the TFT stack with anisotropic geometry was moreover found to be considerable, leading to recommendations for backplane design. The large difference in critical strain of the SiO2 layer on the two substrates was analyzed using an energy release rate approach, and found to result from differences in layer/substrate mechanical contrast and in internal stress state. Based on this analysis a correlation between layer/substrate elastic contrast and tensile failure behavior was devised. (C) 2010 Elsevier Ltd. All rights reserved

    Non PCR-amplified Transcripts and AFLP fragments as reduced representations of the quail genome for 454 Titanium sequencing

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>SNP (Single Nucleotide Polymorphism) discovery is now routinely performed using high-throughput sequencing of reduced representation libraries. Our objective was to adapt 454 GS FLX based sequencing methodologies in order to obtain the largest possible dataset from two reduced representations libraries, produced by AFLP (Amplified Fragment Length Polymorphism) for genomic DNA, and EST (Expressed Sequence Tag) for the transcribed fraction of the genome.</p> <p>Findings</p> <p>The expressed fraction was obtained by preparing cDNA libraries without PCR amplification from quail embryo and brain. To optimize the information content for SNP analyses, libraries were prepared from individuals selected in three quail lines and each individual in the AFLP library was tagged. Sequencing runs produced 399,189 sequence reads from cDNA and 373,484 from genomic fragments, covering close to 250 Mb of sequence in total.</p> <p>Conclusions</p> <p>Both methods used to obtain reduced representations for high-throughput sequencing were successful after several improvements.</p> <p>The protocols may be used for several sequencing applications, such as <it>de novo </it>sequencing, tagged PCR fragments or long fragment sequencing of cDNA.</p

    Rapid diagnostic tests relying on antigen detection from stool as an efficient point of care testing strategy for giardiasis and cryptosporidiosis? Evaluation of a new immunochromatographic duplex assay

    Get PDF
    Microscopy is the gold standard for the diagnosis of gastrointestinal parasites but is time-consuming and dependent on operator skills. Rapid diagnostic tests represent alternative methods but most evaluations have been conducted on a limited number of samples preventing their implementation in the clinical setting. We evaluated a new CE-IVD marked immunochromatographic assay (Crypto/Giardia K-SeTÂź, Coris Bioconcept) for the detection of G. intestinalis and Cryptosporidium spp. in 2 phases (retrospective and prospective) on a set of 482 stool samples including rare Cryptosporidium species. Besides G. intestinalis, this test could represent a rapid and reliable alternative to the modified Ziehl-Neelsen staining for the diagnosis of cryptosporidiosis (sensitivity/specificity were 89.2%/99.3% and 86.7%/100% for G. intestinalis and Cryptosporidium resp.), reducing diagnostic delays. Such strategy would also be time-saving by avoiding wet mount microscopy and concentrations steps, being particularly appropriate for laboratories having little expertise in microscopy or not able to implement molecular diagnostic methods
    • 

    corecore