5,039 research outputs found
Calibration of a turbidity meter for making estimates of total suspended solids concentrations and beam attenuation coefficients in field experiments
Management of water resources such as a reservoir requires using analytical models which describe such parameters as the suspended sediment field. To select or develop an appropriate model requires making many measurements to describe the distribution of this parameter in the water column. One potential method for making those measurements expeditiously is to measure light transmission or turbidity and relate that parameter to total suspended solids concentrations. An instrument which may be used for this purpose was calibrated by generating curves of transmission measurements plotted against measured values of total suspended solids concentrations and beam attenuation coefficients. Results of these experiments indicate that field measurements made with this instrument using curves generated in this study should correlate with total suspended solids concentrations and beam attenuation coefficients in the water column within 20 percent
Semi-analytical model for nonlinear light propagation in strongly interacting Rydberg gases
Rate equation models are extensively used to describe the many-body states of
laser driven atomic gases. We show that the properties of the rate equation
model used to describe nonlinear optical effects arising in interacting Rydberg
gases can be understood by considering the excitation of individual
super-atoms. From this we deduce a simple semi-analytic model that accurately
describes the Rydberg density and optical susceptibility for different
dimensionalities. We identify the previously reported universal dependence of
the susceptibility on the Rydberg excited fraction as an intrinsic property of
the rate equation model that is rooted in one-body properties. Benchmarking
against exact master equation calculations, we identify regimes in which the
semi-analytic model is particularly reliable. The performance of the model
improves in the presence of dephasing which destroys higher order atomic
coherences.Comment: 7 pages, 4 figure
GOES Satellite Observations for the FIRE/SRB Wisconsin Experiment Region from October 11 Through November 2, 1986
A map, concise tables, and satellite images are presented which show ground-site locations, GOES visible/infrared instrument counts above each site, and cloud spatial distribution for the experiment region from 11 October through 2 November 1986. The cloud images are presented near times of the afternoon NOAA-9 satellite overpasses in order to provide a qualitative aid in the interpretation of TOVS, AVHRR, and heat budget data during the FIRE/SRB experiment
Technical innovation changes standard radiographic protocols in veterinary medicine: is it necessary to obtain two dorsoproximal-palmarodistal oblique views of the equine foot when using computerised radiography systems?
Since the 1950s, veterinary practitioners have included two separate dorsoproximal–palmarodistal oblique (DPr–PaDiO) radiographs as part of a standard series of the equine foot. One image is obtained to visualise the distal phalanx and the other to visualise the navicular bone. However, rapid development of computed radiography and digital radiography and their post-processing capabilities could mean that this practice is no longer required. The aim of this study was to determine differences in perceived image quality between DPr–PaDiO radiographs that were acquired with a computerised radiography system with exposures, centring and collimation recommended for the navicular bone versus images acquired for the distal phalanx but were subsequently manipulated post-acquisition to highlight the navicular bone. Thirty images were presented to four clinicians for quality assessment and graded using a 1–3 scale (1=textbook quality, 2=diagnostic quality, 3=non-diagnostic image). No significant difference in diagnostic quality was found between the original navicular bone images and the manipulated distal phalanx images. This finding suggests that a single DPr–PaDiO image of the distal phalanx is sufficient for an equine foot radiographic series, with appropriate post-processing and manipulation. This change in protocol will result in reduced radiographic study time and decreased patient/personnel radiation exposure
Laboratory measurements of radiance and reflectance spectra of dilute secondary-treated sewage sludge
The National Aeronautics and Space Administration (NASA), in cooperation with the Environmental Protection Agency (EPA) and the National Oceanic and Atmospheric Administration (NOAA), conducted a research program to evaluate the feasibility of remotely monitoring ocean dumping of waste products such as acid and sewage sludge. One aspect of the research program involved the measurements of upwelled spectral signatures for sewage-sludge mixtures of different concentrations in an 11600-liter tank. This paper describes the laboratory arrangement and presents radiance and reflectance spectra in the visible and near-infrared ranges for concentrations ranging from 9.7 to 180 ppm of secondary-treated sewage sludge mixed with two types of base water. Results indicate that upwelled radiance varies in a near-linear manner with concentration and that the sludge has a practically flat signal response between 420 and 970 nm. Reflectance spectra were obtained for the sewage-sludge mixtures at all wavelengths and concentrations
Automated Data Management Information System (ADMIS)
ADMIS stores and controls data and documents associated with manned space flight effort. System contains all data oriented toward a specific document; it is primary source of reports generated by the system. Each group of records is composed of one document record, one distribution record for each recipient of the document, and one summary record
Relaxation of an isolated dipolar-interacting Rydberg quantum spin system
How do isolated quantum systems approach an equilibrium state? We
experimentally and theoretically address this question for a prototypical spin
system formed by ultracold atoms prepared in two Rydberg states with different
orbital angular momenta. By coupling these states with a resonant microwave
driving we realize a dipolar XY spin-1/2 model in an external field. Starting
from a spin-polarized state we suddenly switch on the external field and
monitor the subsequent many-body dynamics. Our key observation is density
dependent relaxation of the total magnetization much faster than typical
decoherence rates. To determine the processes governing this relaxation we
employ different theoretical approaches which treat quantum effects on initial
conditions and dynamical laws separately. This allows us to identify an
intrinsically quantum component to the relaxation attributed to primordial
quantum fluctuations.Comment: 6 pages, 3 figure
Laboratory measurements of radiance and reflectance spectra of dilute primary-treated sewage sludge
The feasibility of remotely monitoring ocean dumping of waste products such as acid and sewage sludge is evaluated. The laboratory arrangement, solar simulator, and test results from three experiments conducted in the laboratory are described. Radiance and reflectance spectra are presented for primary-treated sewage sludge mixed with two types of base water. Results indicate that upwelled reflectance varies in a near-linear manner with concentration and that the sludge has a practically flat signal response between 420 and 970 nm. Well-defined upwelled reflectance spectra were obtained for the sewage-sludge mixtures at all wavelengths and concentrations. The spectral-reflectance values appeared to be influenced by the type of base water, but this influence was small, especially for the mixtures with low concentrations of sewage sludge
Laboratory measurements of physical, chemical, and optical characteristics of Lake Chicot sediment waters
Reflectance, chromaticity, diffuse attenuation, beam attenuation, and several other physical and chemical properties were measured for various water mixtures of lake bottom sediment. Mixture concentrations range from 5 ppm to 700 ppm by weight of total suspended solids in filtered deionized tap water. Upwelled reflectance is a nonlinear function of remote sensing wave lengths. Near-infrared wavelengths are useful for monitoring highly turbid waters with sediment concentrations above 100 ppm. It is found that both visible and near infrared wavelengths, beam attenuation correlates well with total suspended solids ranging over two orders of magnitude
Three-dimensional character of atom-chip-based rf-dressed potentials
We experimentally investigate the properties of radio-frequency-dressed
potentials for Bose-Einstein condensates on atom chips. The three-dimensional
potential forms a connected pair of parallel waveguides. We show that
rf-dressed potentials are robust against the effect of small magnetic-field
variations on the trap potential. Long-lived dipole oscillations of condensates
induced in the rf-dressed potentials can be tuned to a remarkably low damping
rate. We study a beam-splitter for Bose-Einstein condensates and show that a
propagating condensate can be dynamically split in two vertically separated
parts and guided along two paths. The effect of gravity on the potential can be
tuned and compensated for using a rf-field gradient.Comment: 9 pages, 7 figure
- …