40,221 research outputs found

    System for sterilizing objects

    Get PDF
    A system for producing a stream of humidified sterilizing gas for sterilizing objects such as the water systems of space vehicles and the like includes a source of sterilant gas which is fed to a mixing chamber which has inlet and outlet ports. The level of the water only partially fills the mixing chamber so as to provide an empty space adjacent the top of the chamber. A heater is provided for heating the water in the chamber so as to produce a humidified atmosphere. The sterilant gas is fed through an arcuate shaped tubular member connected to the inlet port of the mixing chamber for producing a vortex type of flow of sterilant gas into the chamber for humidification. A tubular member extends from the mixing chamber for supplying the humidified sterilant gas to the object for being sterilized. Scrubbers are provided for removing the sterilant gas after use

    Risk factors of lameness in sows in England

    Get PDF

    Optical photometric GTC/OSIRIS observations of the young massive association Cygnus OB2

    Get PDF
    In order to fully understand the gravitational collapse of molecular clouds, the star formation process and the evolution of circumstellar disks, these phenomena must be studied in different Galactic environments with a range of stellar contents and positions in the Galaxy. The young massive association Cygnus OB2, in the Cygnus-X region, is an unique target to study how star formation and the evolution of circumstellar disks proceed in the presence of a large number of massive stars. We present a catalog obtained with recent optical observations in r,i,z filters with OSIRIS, mounted on the 10.4m10.4\,m GTC telescope, which is the deepest optical catalog of Cyg OB2 to date. The catalog consist of 64157 sources down to M=0.15 solar masses at the adopted distance and age of Cyg OB2. A total of 38300 sources have good photometry in all three bands. We combined the optical catalog with existing X-ray data of this region, in order to define the cluster locus in the optical diagrams. The cluster locus in the r-i vs. i-z diagram is compatible with an extinction of the optically selected cluster members in the 2.64<AV<5.57 range. We derive an extinction map of the region, finding a median value of AV=4.33 in the center of the association, decreasing toward the north-west. In the color-magnitude diagrams, the shape of the distribution of main sequence stars is compatible with the presence of an obscuring cloud in the foreground at about 850+/-25 pc from the Sun.Comment: Accepted for publication ApJS 201

    Evaluation of the implementation of the alert issued by the UK National Patient Safety Agency on the storage and handling of potassium chloride concentrate solution

    Get PDF
    Objectives: To assess the effectiveness of the response of NHS hospital trusts to an alert issued by the National Patient Safety Agency designed to limit the availability of concentrated potassium chloride in hospitals in England and Wales, and to determine the nature of any unintended consequences. Design: Multi-method study involving interviews and a physical inspection of clinical areas. Setting: 207 clinical areas in 20 randomly selected acute NHS trusts in England and Wales between 31 October 2002 and 31 January 2003. Participants: Senior managers and ward based medical and nursing staff. Main outcome measures: Degree of staff awareness of and compliance with the requirements of the national alert, withdrawal of concentrated potassium chloride solutions from non-critical areas, provision of pre-diluted alternatives, storage and recording in accordance with controlled drug legislation. Results: All trusts required that potassium chloride concentrate be stored in a separate locked cupboard from common injectable diluents (100% compliance). Unauthorised stocks of potassium chloride were found in five clinical areas not authorised by the trust (98% compliance). All trusts required documentation control of potassium chloride concentrate in clinical areas, but errors were recorded in 20 of the 207 clinical areas visited (90% compliance). Of those interviewed, 78% of nurses and 30% of junior doctors were aware of the alert. Conclusions: The NPSA alert was effective and resulted in rapid development and implementation of local policies to reduce the availability of concentrated potassium chloride solutions. The success is likely to be partly due to the nature of the proposed changes and it cannot be assumed that future alerts will be equally effective. Continued vigilance will be necessary to help sustain the changes

    Two-body anticorrelation in a harmonically trapped ideal Bose gas

    Get PDF
    We predict the existence of a dip below unity in the second-order coherence function of a partially condensed ideal Bose gas in harmonic confinement, signaling the anticorrelation of density fluctuations in the sample. The dip in the second-order coherence function is revealed in a canonical-ensemble calculation, corresponding to a system with fixed total number of particles. In a grand-canonical ensemble description, this dip is obscured by the occupation-number fluctuation catastrophe of the ideal Bose gas. The anticorrelation is most pronounced in highly anisotropic trap geometries containing small particle numbers. We explain the fundamental physical mechanism which underlies this phenomenon, and its relevance to experiments on interacting Bose gases.Comment: 10 pages, 5 figures. v2: Minor changes and corrections to figures and text. To appear in PR
    corecore