1,126 research outputs found

    Design and Evaluation of Pediatric Gait Rehabilitation Robots

    Get PDF
    Gait therapy methodologies were studied and analyzed for their potential for pediatric patients. Using data from heel, metatarsal, and toe trajectories, a nominal gait trajectory was determined using Fourier transforms for each foot point. These average trajectories were used as a basis of evaluating each gait therapy mechanism. An existing gait therapy device (called ICARE) previously designed by researchers, including engineers at the University of Nebraska-Lincoln, was redesigned to accommodate pediatric patients. Unlike many existing designs, the pediatric ICARE did not over- or under-constrain the patient’s leg, allowing for repeated, comfortable, easily-adjusted gait motions. This design was assessed under clinical testing and deemed to be acceptable. A gait rehabilitation device was designed to interface with both pediatric and adult patients and more closely replicate the gait-like metatarsal trajectory compared to an elliptical machine. To accomplish this task, the nominal gait path was adjusted to accommodate for rotation about the toe, which generated a new trajectory that was tangent to itself at the midpoint of the stride. Using knowledge of the bio-mechanics of the foot, the gait path was analyzed for its applicability to the general population. Several trajectory-replication methods were evaluated, and the crank-slider mechanism was chosen for its superior performance and ability to mimic the gait path adequately. Adjustments were made to the gait path to further optimize its realization through the crank-slider mechanism. Two prototypes were constructed according to the slider-crank mechanism to replicate the gait path identified. The first prototype, while more accurately tracing the gait path, showed difficulty in power transmission and excessive cam forces. This prototype was ultimately rejected. The second prototype was significantly more robust. However, it lacked several key aspects of the original design that were important to matching the design goals. Ultimately, the second prototype was recommended for further work in gait-replication research. Advisor: Carl A. Nelso

    Numerical Simulation of III-V Solar Cells Using D-AMPS

    Get PDF
    Numerical simulation of devices plays a crucial role in their design, performance prediction, and comprehension of the fundamental phenomena ruling their operation. Here, we present results obtained using the code D-AMPS-1D, that was conveniently modified to consider the particularities of III-V solar cell devices. This work, that is a continuation of a previous paper regarding solar cells for space applications, is focused on solar cells structures than find application for terrestrial use under concentrated solar illumination. The devices were fabricated at the Solar Energy Institute of the Technical University of Madrid (UPM). The first simulations results on InGaP cells are presented. The influence of band offsets and band bending at the window-emitter interface on the quantum efficiency was studied. A remarkable match of the experimental quantum efficiency was obtained. Finally, numerical simulation of single junction n-p InGaP-Ge solar cells was performed

    Do Pennsylvania Casinos Cannibalize PA State Lottery Revenues?

    Get PDF
    The first Pennsylvania casino opened its doors in 2006. Studies of other states, and nationally, indicate that casinos cannibalize lottery revenues as consumers substitute lottery spending for casino spending. Pennsylvania time-series data and cross-sectional data for each county suggests that higher casino wagering leads to lower lottery spending. Unlike the other studies, Pennsylvania\u27s rate of cannibalization is relatively low where state lottery revenues decline by five to fifteen cents for each dollar of casino revenue gained. About half of the cannibalization takes place in the counties where the casino resided

    Comparing plasma bubble occurrence rates at CHAMP and GRACE altitudes during high and low solar activity

    Get PDF
    Based on the multi-year data base (2001–2009) of CHAMP Planar Langmuir Probe (PLP) data and GRACE K-Band Ranging (KBR1B) data, typical features of ionospheric plasma irregularities are studied at the altitudes of CHAMP (300–400 km) and GRACE (~500 km). The phenomena we are focusing on are the equatorial plasma bubbles (EPBs). Similar seasonal/longitudinal (S/L) distributions of EPB have been found at both CHAMP and GRACE altitudes during solar active and quiet years. Peak EPB occurrence rates, defined as number of events within an S/L bin divided by the number of passes over that bin, decrease from the high and moderate solar flux period (2001–2005) to the low solar flux period (2005–2009) from 80% to 60% and 60% to 40% at CHAMP and GRACE altitudes, respectively. On average the occurrence rate increases linearly with solar flux at about the same rate at CHAMP and GRACE. For high flux levels (P10.7>200) non-linear increases are observed at GRACE. The occurrence rate increases rapidly after 19:00 local time (LT) during high solar flux periods. Around solar minimum rates increase more gently and peak around 22:00 LT. The highest occurrence rates are encountered at latitudes around 10° north and south of the dip equator. Results from the two altitudes support the notion that EPBs form regions of depleted plasma along geomagnetic fluxtubes. It is shown for the first time that in regions of high occurrence rates EPBs are associated with fluxtubes reaching greater apex heights than those in regions of low rates

    Biomechanical Foot Guidance Linkage

    Get PDF
    A gait replication apparatus can include a scalable mechanical mechanism configured to replicate different gaits . The scalable mechanical mechanism can include , for example , a four - bar linkage , a pantograph , a cam / Scotch - yoke mechanism , and so forth . In some embodiments , the mechanical mechanism includes a beam rotating about an axis passing proximate to its center , with a foot pedal slidably coupled with the beam , and a timing chain / belt or cable pulley - pair coupled with the foot pedal and looped about the beam . A method can include decomposing a foot path defined by Cartesian coordinates into polar coordinates , and providing a mechanical support for a foot , where a first mechanism controls an angular position of the mechanical support with respect to a reference frame , and a second mechanism controls a radial distance of the mechanical support from the reference frame

    Simulação do impacto das atividades florestais na fragilidade potencial em plantios de pinus.

    Get PDF
    Este trabalho, realizado em uma área com povoamento de Pinus taeda, teve por objetivo simular e mapear a influência do valor de impacto das atividades florestais na fragilidade potencial. Variáveis do solo, de declividade do terreno, valor de impacto e de cobertura vegetal foram utilizadas para gerar os mapas. Os resultados expressos pelo modelo adotado mostraram que as áreas mais frágeis apresentam em sua maioria declividades superiores a 75 % e textura que variam de arenosa a média, e as áreas menos frágeis apresentam predominantemente relevo plano (até 3 %) e textura argilosa. Quando simulado o impacto das atividades florestais sobre esse ambiente, verificou-se que na maior parte da área (78 %) todas as atividades florestais podem ser realizadas sem influência na degradação do meio ambiente e para algumas áreas (11 %) o ambiente foi considerado menos frágil, em razão da presença de cobertura vegetal
    • …
    corecore