88 research outputs found
Proposal of Real-Time Echocardiogram Transmission Based on Visualization Modes with WiMAX Access
This study presents a new approach to improve the echocardiogram transmissions over WiMAX networks. Using a compression method based on visualization modes and a reliable method that adapts to the channel conditions, overall performance results are improved compared to classical approaches. The echocardiogram transmission using a compression method based on visualization modes requires lower bandwidth than without considering visualization modes. Furthermore, if the proposed reliability method is also used, the echocardiogram is more often visualized with adequate clinical quality than compressing the echocardiogram without distinguishing the visualization modes and without using a reliability method for the available dataset. The reduction in the bandwidth ranges from 29 kbps to 166 kbps for the simulated scenarios. 1
Itch and skin rash from chocolate during fluoxetine and sertraline treatment: Case report
BACKGROUND: The skin contains a system for producing serotonin as well as serotonin receptors. Serotonin can also cause pruritus when injected into the skin. SSRI-drugs increase serotonin concentrations and are known to have pruritus and other dermal side effects. CASE PRESENTATION: A 46-year-old man consulted his doctor due to symptoms of depression. He did not suffer from any allergy but drinking red wine caused vasomotor rhinitis. Antidepressive treatment with fluoxetine 20 mg daily was initiated which was successful. After three weeks of treatment an itching rash appeared. An adverse drug reaction (ADR) induced by fluoxetine was suspected and fluoxetine treatment was discontinued. The symptoms disappeared with clemastine and betametasone treatment. Since the depressive symptoms returned sertraline medication was initiated. After approximately two weeks of sertraline treatment he noted an intense itching sensation in his scalp after eating a piece of chocolate cake. The itch spread to the arms, abdomen and legs and the patient treated himself with clemastine and the itch disappeared. He now realised that he had eaten a chocolate cake before this episode and remembered that before the first episode he had had a chocolate mousse dessert. He had never had any reaction from eating chocolate before and therefore reported this observation to his doctor. CONCLUSIONS: This case report suggests that there may be individuals that are very sensitive to increases in serotonin concentrations. Dermal side reactions to SSRI-drugs in these patients may be due to high activity in the serotonergic system at the dermal and epidermo-dermal junctional area rather than a hypersensitivity to the drug molecule itself
Carotid Ultrasound Boundary Study (CUBS): An Open Multicenter Analysis of Computerized Intima–Media Thickness Measurement Systems and Their Clinical Impact
[Abstract] Common carotid intima–media thickness (CIMT) is a commonly used marker for atherosclerosis and is often computed in carotid ultrasound images. An analysis of different computerized techniques for CIMT measurement and their clinical impacts on the same patient data set is lacking. Here we compared and assessed five computerized CIMT algorithms against three expert analysts’ manual measurements on a data set of 1088 patients from two centers. Inter- and intra-observer variability was assessed, and the computerized CIMT values were compared with those manually obtained. The CIMT measurements were used to assess the correlation with clinical parameters, cardiovascular event prediction through a generalized linear model and the Kaplan–Meier hazard ratio. CIMT measurements obtained with a skilled analyst's segmentation and the computerized segmentation were comparable in statistical analyses, suggesting they can be used interchangeably for CIMT quantification and clinical outcome investigation. To facilitate future studies, the entire data set used is made publicly available for the community at http://dx.doi.org/10.17632/fpv535fss7.
Carotid Ultrasound Boundary Study (CUBS): An Open Multicenter Analysis of Computerized Intima–Media Thickness Measurement Systems and Their Clinical Impact
Common carotid intima–media thickness (CIMT) is a commonly used marker for atherosclerosis and is often computed in carotid ultrasound images. An analysis of different computerized techniques for CIMT measurement and their clinical impacts on the same patient data set is lacking. Here we compared and assessed five computerized CIMT algorithms against three expert analysts’ manual measurements on a data set of 1088 patients from two centers. Inter- and intra-observer variability was assessed, and the computerized CIMT values were compared with those manually obtained. The CIMT measurements were used to assess the correlation with clinical parameters, cardiovascular event prediction through a generalized linear model and the Kaplan–Meier hazard ratio. CIMT measurements obtained with a skilled analyst's segmentation and the computerized segmentation were comparable in statistical analyses, suggesting they can be used interchangeably for CIMT quantification and clinical outcome investigation. To facilitate future studies, the entire data set used is made publicly available for the community at http://dx.doi.org/10.17632/fpv535fss7.1
Techniques of EMG signal analysis: detection, processing, classification and applications
Electromyography (EMG) signals can be used for clinical/biomedical applications, Evolvable Hardware Chip (EHW) development, and modern human computer interaction. EMG signals acquired from muscles require advanced methods for detection, decomposition, processing, and classification. The purpose of this paper is to illustrate the various methodologies and algorithms for EMG signal analysis to provide efficient and effective ways of understanding the signal and its nature. We further point up some of the hardware implementations using EMG focusing on applications related to prosthetic hand control, grasp recognition, and human computer interaction. A comparison study is also given to show performance of various EMG signal analysis methods. This paper provides researchers a good understanding of EMG signal and its analysis procedures. This knowledge will help them develop more powerful, flexible, and efficient applications
The reference site collaborative network of the european innovation partnership on active and healthy ageing
Seventy four Reference Sites of the European Innovation
Partnership on Active and Healthy Ageing (EIP on AHA)
have been recognised by the European Commission in
2016 for their commitment to excellence in investing and
scaling up innovative solutions for active and healthy
ageing. The Reference Site Collaborative Network
(RSCN) brings together the EIP on AHA Reference Sites
awarded by the European Commission, and Candidate
Reference Sites into a single forum. The overarching goals
are to promote cooperation, share and transfer good
practice and solutions in the development and scaling up
of health and care strategies, policies and service delivery
models, while at the same time supporting the action
groups in their work. The RSCN aspires to be recognized
by the EU Commission as the principal forum and
authority representing all EIP on AHA Reference Sites.
The RSCN will contribute to achieve the goals of the EIP
on AHA by improving health and care outcomes for
citizens across Europe, and the development of sustainable
economic growth and the creation of jobs
- …