131 research outputs found

    M2000 : an astrometric catalog in the Bordeaux Carte du Ciel zone +11 degrees < {delta} < +18 degrees

    Full text link
    During four years, systematic observations have been conducted in drift scan mode with the Bordeaux automated meridian circle in the declination band [+11 ; +18]. The resulting astrometric catalog includes about 2 300 000 stars down to the magnitude limit V_M=16.3. Nearly all stars (96%) have been observed at least 6 times, the catalog being complete down to V_M=15.4. The median internal standard error in position is about 35 mas in the V_M magnitude range [11 ; 15], which degrades to about 50 mas when the faintest stars are considered. M2000 provides also one band photometry with a median internal standard error of 0.04 mag. Comparisons with the Hipparcos and bright part of Tycho-2 catalogs have enabled to estimate external errors in position to be lower than 40 mas. In this zone and at epoch 1998, the faint part of Tycho-2 is found to have an accuracy of 116 mas in alpha instead of 82 mas deduced from the model-based standard errors given in the catalog.Comment: The catalogue can be fetched directly from: ftp://cdsarc.u-strasbg.fr/cats/I/272 or queried from: http://vizier.u-strasbg.fr/viz-bin/VizieR?-source=I/272 More information at : http://www.observ.u-bordeaux.fr/~soubiran/m2000.ht

    Effect of pathology type and severity on the distribution of MRI signal intensities within the degenerated nucleus pulposus: application to idiopathic scoliosis and spondylolisthesis

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>Disc degeneration is characterized by a loss of cellularity, degradation of the extracellular matrix, and, as a result, morphological changes and biomechanical alterations. We hypothesized that the distribution of the MR signal intensity within the nucleus zone of the intervertebral disc was modified according to the pathology and the severity of the pathology. The objective of this study was to propose new parameters characterizing the distribution of the signal intensity within the nucleus zone of lumbar intervertebral discs, and to quantify these changes in patients suffering from spondylolisthesis or idiopathic scoliosis.</p> <p>Methods</p> <p>A retrospective study had been performed on T2-weighted MR images of twenty nine patients suffering from spondylolisthesis and/or scoliosis. The high intensity zone of the nucleus pulposus was semi-automatically detected. The distance "DX" between the center weighted by the signal intensity and the geometrical center was quantified. The sum of the signal intensity on the axis perpendicular to the longitudinal axis of the disc was plotted for each position of the longitudinal axis allowing defining the maximum sum "SM" and its position "PSM".</p> <p>Results</p> <p>"SM" was clearly higher and "PSM" was more shifted for scoliosis than for spondylolisthesis. A two-way analysis of variance showed that the differences observed on "DX" were not attributed to the pathology nor its severity, the differences observed on "SM" were attributed to the pathology but not to its severity, and the differences observed on "PSM" were attributed to both the pathology and its severity.</p> <p>Conclusions</p> <p>The technique proposed in this study showed significant differences in the distribution of the MR signal intensity within the nucleus zone of intervertebral discs due to the pathology and its severity. The dependence of the "PSM" parameter to the severity of the pathology suggests this parameter as a predictive factor of the pathology progression. This new technique should be useful for the early diagnosis of intervertebral disc pathologies as it highlights abnormal patterns in the MRI signal for low severity of the pathology.</p

    Design and construction of a Cherenkov imager for charge measurement of nuclear cosmic rays

    Full text link
    A proximity focusing Cherenkov imager called CHERCAM, has been built for the charge measurement of nuclear cosmic rays with the CREAM instrument. It consists of a silica aerogel radiator plane across from a detector plane equipped with 1,600 1" diameter photomultipliers. The two planes are separated by a ring expansion gap. The Cherenkov light yield is proportional to the charge squared of the incident particle. The expected relative light collection accuracy is in the few percents range. It leads to an expected single element separation over the range of nuclear charge Z of main interest 1 < Z < 26. CHERCAM is designed to fly with the CREAM balloon experiment. The design of the instrument and the implemented technical solutions allowing its safe operation in high altitude conditions (radiations, low pressure, cold) are presented.Comment: 24 pages, 19 figure

    Structure et configuration du bis{[ O

    Full text link

    CHERCAM: A Cherenkov imager for the CREAM experiment

    No full text
    International audienceThe CREAM experiment (Cosmic Ray Energetics and Mass) is dedicated to the measurement of the energy spectrum of nuclear elements in cosmic rays, over the range 1012^{12} to 1015^{15} eV. The individual elements separation, which is a key feature of CREAM, requires instruments with strong identification capabilities. A proximity focused type of Cherenkov imager, CHERCAM (CHERenkov CAMera), providing both a good signature of downgoing Z=1 particles and good single element separation through the whole range of nuclear charges [Buénerd et al. 28th ICRC, Tsukuba, OG 1.5, 2003, p. 2157], is under development. After a brief introduction, the main features and the construction status of the CHERCAM are being summarized

    A Cherenkov imager for charge measurements of Nuclear Cosmic Rays in the CREAM II instrument

    No full text
    A proximity focusing Cherenkov imager for the charge measurement of nuclear cosmic rays in the CREAM II instrument, called CHERCAM, is under construction. This imager consists of a silica aerogel radiator plane facing a detector plane equipped with standard photomultipliers. The two planes are separated by a minimal ring expansion gap. The Cherenkov light yield is proportional to the squared charge of the detected particle. The expected relative light collection accuracy is in the few percents range. It should lead to single element separation over the range of nuclear charge Z of main interest 1 leqleq Z <<\approx$ 26

    CHERCAM: the Cherenkov imager of the CREAM experiment, results in Z=1 test beams

    No full text
    International audienceThe CREAM experiment investigates the high energy spectrum of nuclear elements from H to Fe in the cosmic ray flux up to 101510^{15} eV, with an instrument designed to achieve individual elements separation over the whole mass range. A proximity focused Cherenkov imager, CHERCAM (CHERenkov CAMera), will provide both a good topological signature (Cherenkov ring) for downgoing Z=1 particles, and a charge independent individual element separation through the considered range of nuclear charges. It will be implemented in the forthcoming CREAM flight 3. The contribution reports on the CHERCAM main features and on the preliminary results from in-beam tests at CERN

    Detection of occult carcinomatous diffusion in lymph nodes from head and neck squamous cell carcinoma using real-time RT–PCR detection of cytokeratin 19 mRNA

    Get PDF
    The aim of the present study was to evaluate the occult lymph node carcinomatous diffusion in head and neck squamous cell carcinoma (HNSCC). A total of 1328 lymph nodes from 31 patients treated between 2004 and 2005 were prospectively evaluated by routine haematoxylin–eosin–safran (HES) staining, immunohistochemistry (IHC) and real-time Taqman reverse–transcriptase polymerase chain reaction (real-time RT–PCR) assay. Amplification of cytokeratin 19 (CK19) mRNA transcripts using real-time RT–PCR was used to quantify cervical micrometastatic burden. The cervical lymph node metastatic rates determined by routine HES staining and real-time RT–PCR assay were 16.3 and 36.0%, respectively (P<0.0001). A potential change in the nodal status was observed in 13 (42.0%) of the 31 patients and an atypical pattern of lymphatic spread was identified in four patients (12.9%). Moreover, CK19 mRNA expression values in histologically positive lymph nodes were significantly higher than those observed in histologically negative lymph nodes (P<0.0001). These results indicate that real-time RT–PCR assay for the detection of CK19 mRNA is a sensitive and reliable method for the detection of carcinomatous cells in lymph nodes. This type of method could be used to reassess lymph node status according to occult lymphatic spread in patients with HNSCC

    The Effect of Sustained Compression on Oxygen Metabolic Transport in the Intervertebral Disc Decreases with Degenerative Changes

    Get PDF
    Intervertebral disc metabolic transport is essential to the functional spine and provides the cells with the nutrients necessary to tissue maintenance. Disc degenerative changes alter the tissue mechanics, but interactions between mechanical loading and disc transport are still an open issue. A poromechanical finite element model of the human disc was coupled with oxygen and lactate transport models. Deformations and fluid flow were linked to transport predictions by including strain-dependent diffusion and advection. The two solute transport models were also coupled to account for cell metabolism. With this approach, the relevance of metabolic and mechano-transport couplings were assessed in the healthy disc under loading-recovery daily compression. Disc height, cell density and material degenerative changes were parametrically simulated to study their influence on the calculated solute concentrations. The effects of load frequency and amplitude were also studied in the healthy disc by considering short periods of cyclic compression. Results indicate that external loads influence the oxygen and lactate regional distributions within the disc when large volume changes modify diffusion distances and diffusivities, especially when healthy disc properties are simulated. Advection was negligible under both sustained and cyclic compression. Simulating degeneration, mechanical changes inhibited the mechanical effect on transport while disc height, fluid content, nucleus pressure and overall cell density reductions affected significantly transport predictions. For the healthy disc, nutrient concentration patterns depended mostly on the time of sustained compression and recovery. The relevant effect of cell density on the metabolic transport indicates the disturbance of cell number as a possible onset for disc degeneration via alteration of the metabolic balance. Results also suggest that healthy disc properties have a positive effect of loading on metabolic transport. Such relation, relevant to the maintenance of the tissue functional composition, would therefore link disc function with disc nutrition
    corecore