7,891 research outputs found
Effect of continuous gamma-ray exposure on performance of learned tasks and effect of subsequent fractionated exposures on blood-forming tissue
Sixteen monkeys trained to perform continuous and discrete-avoidance and fixed-ratio tasks with visual and auditory cues were performance-tested before, during, and after 10-day gamma-ray exposures totaling 0, 500, 750, and 1000 rads. Approximately 14 months after the performance-test exposures, surviving animals were exposed to 100-rad gamma-ray fractions at 56-day intervals to observe injury and recovery patterns of blood-forming tissues. The fixed-ratio, food-reward task performance showed a transient decline in all dose groups within 24 hours of the start of gamma-ray exposure, followed by recovery to normal food-consumption levels within 48 to 72 hours. Avoidance tasks were performed successfully by all groups during the 10-day exposure, but reaction times of the two higher dose-rate groups in which animals received 3 and 4 rads per hour or total doses of 750 and 1000 rads, respectively, were somewhat slower
Multidimensional collaboration; reflections on action research in a clinical context
This paper reflects on the challenges and benefits of multidimensional collaboration in an action research study to evaluate and improve preoperative education for patients awaiting colorectal surgery. Three cycles of planning, acting,observing and reflecting were designed to evaluate practice and implement change in this interactive setting, calling for specific and distinct collaborations. Data collection includes: observing educational interactions; administering patient evaluation questionnaires; interviewing healthcare staff, patients and carers; patient and carer focus groups; and examining written and audiovisual educational materials. The study revolves around and depends on multi-dimensional collaborations. Reflecting on these collaborations highlights the diversity of perspectives held by all those engaged in the study and enhances the action research lessons. Successfully maintaining the collaborations recognises the need for negotiation, inclusivity, comprehension, brokerage,and problem-solving. Managing the potential tensions is crucial to the successful implementation of changes introduced to practice and thus has important implications for patients’ well-being. This paper describes the experiences from an action research project involving new and specific collaborations, focusing on a particular healthcare setting. It exemplifies the challenges of the collaborative action research process and examines how both researchers and practitioners might reflect on the translation of theory into educational practices within a hospital colorectal department. Despite its context-specific features, the reflections on the types of challenges faced and lessons learned provide implications for action researchers in diverse healthcare settings across the world
Bar coding MS2 spectra for metabolite identification
[Image: see text] Metabolite identifications are most frequently achieved in untargeted metabolomics by matching precursor mass and full, high-resolution MS(2) spectra to metabolite databases and standards. Here we considered an alternative approach for establishing metabolite identifications that does not rely on full, high-resolution MS(2) spectra. First, we select mass-to-charge regions containing the most informative metabolite fragments and designate them as bins. We then translate each metabolite fragmentation pattern into a binary code by assigning 1’s to bins containing fragments and 0’s to bins without fragments. With 20 bins, this binary-code system is capable of distinguishing 96% of the compounds in the METLIN MS(2) library. A major advantage of the approach is that it extends untargeted metabolomics to low-resolution triple quadrupole (QqQ) instruments, which are typically less expensive and more robust than other types of mass spectrometers. We demonstrate a method of acquiring MS(2) data in which the third quadrupole of a QqQ instrument cycles over 20 wide isolation windows (coinciding with the location and width of our bins) for each precursor mass selected by the first quadrupole. Operating the QqQ instrument in this mode yields diagnostic bar codes for each precursor mass that can be matched to the bar codes of metabolite standards. Furthermore, our data suggest that using low-resolution bar codes enables QqQ instruments to make MS(2)-based identifications in untargeted metabolomics with a specificity and sensitivity that is competitive to high-resolution time-of-flight technologies
Accessory cells in Murine Peyer’s patch: I. Identification and enrichment of a functional dendritic cell
[No abstract available
Simultaneous Water Vapor and Dry Air Optical Path Length Measurements and Compensation with the Large Binocular Telescope Interferometer
The Large Binocular Telescope Interferometer uses a near-infrared camera to
measure the optical path length variations between the two AO-corrected
apertures and provide high-angular resolution observations for all its science
channels (1.5-13 m). There is however a wavelength dependent component to
the atmospheric turbulence, which can introduce optical path length errors when
observing at a wavelength different from that of the fringe sensing camera.
Water vapor in particular is highly dispersive and its effect must be taken
into account for high-precision infrared interferometric observations as
described previously for VLTI/MIDI or the Keck Interferometer Nuller. In this
paper, we describe the new sensing approach that has been developed at the LBT
to measure and monitor the optical path length fluctuations due to dry air and
water vapor separately. After reviewing the current performance of the system
for dry air seeing compensation, we present simultaneous H-, K-, and N-band
observations that illustrate the feasibility of our feedforward approach to
stabilize the path length fluctuations seen by the LBTI nuller.Comment: SPIE conference proceeding
High Spatial Resolution Thermal-Infrared Spectroscopy with ALES: Resolved Spectra of the Benchmark Brown Dwarf Binary HD 130948BC
We present 2.9-4.1 micron integral field spectroscopy of the L4+L4 brown
dwarf binary HD 130948BC, obtained with the Arizona Lenslets for Exoplanet
Spectroscopy (ALES) mode of the Large Binocular Telescope Interferometer
(LBTI). The HD 130948 system is a hierarchical triple system, in which the G2V
primary is joined by two co-orbiting brown dwarfs. By combining the age of the
system with the dynamical masses and luminosities of the substellar companions,
we can test evolutionary models of cool brown dwarfs and extra-solar giant
planets. Previous near-infrared studies suggest a disagreement between HD
130948BC luminosities and those derived from evolutionary models. We obtained
spatially-resolved, low-resolution (R~20) L-band spectra of HD 130948B and C to
extend the wavelength coverage into the thermal infrared. Jointly using JHK
photometry and ALES L-band spectra for HD 130948BC, we derive atmospheric
parameters that are consistent with parameters derived from evolutionary
models. We leverage the consistency of these atmospheric quantities to favor a
younger age (0.50 \pm 0.07 Gyr) of the system compared to the older age (0.79
\pm 0.22 Gyr) determined with gyrochronology in order to address the luminosity
discrepancy.Comment: 17 pages, 9 figures, Accepted to Ap
Exoplanet science with the LBTI: instrument status and plans
The Large Binocular Telescope Interferometer (LBTI) is a strategic instrument
of the LBT designed for high-sensitivity, high-contrast, and high-resolution
infrared (1.5-13 m) imaging of nearby planetary systems. To carry out a
wide range of high-spatial resolution observations, it can combine the two
AO-corrected 8.4-m apertures of the LBT in various ways including direct
(non-interferometric) imaging, coronagraphy (APP and AGPM), Fizeau imaging,
non-redundant aperture masking, and nulling interferometry. It also has
broadband, narrowband, and spectrally dispersed capabilities. In this paper, we
review the performance of these modes in terms of exoplanet science
capabilities and describe recent instrumental milestones such as first-light
Fizeau images (with the angular resolution of an equivalent 22.8-m telescope)
and deep interferometric nulling observations.Comment: 12 pages, 6 figures, Proc. SPI
- …