3,863 research outputs found

    Absolute Calibration of a Large-diameter Light Source

    Get PDF
    A method of absolute calibration for large aperture optical systems is presented, using the example of the Pierre Auger Observatory fluorescence detectors. A 2.5 m diameter light source illuminated by an ultra--violet light emitting diode is calibrated with an overall uncertainty of 2.1 % at a wavelength of 365 nm.Comment: 15 pages, 8 figures. Submitted to JINS

    Absolute Calibration of the Auger Fluorescence Detectors

    Get PDF
    Absolute calibration of the Pierre Auger Observatory fluorescence detectors uses a light source at the telescope aperture. The technique accounts for the ombined effects of all detector components in a single measurement. The calibrated 2.5 m diameter light source fills the aperture, providing uniform illumination to each pixel. The known flux from the light source and the response of the acquisition system give the required calibration for each pixel. In the lab, light source uniformity is studied using CCD images and the intensity is measured relative to NIST-calibrated photodiodes. Overall uncertainties are presently 12%, and are dominated by systematics.Comment: 4 pages, 3 figure. Submitted to the 29th ICRC, Pune, Indi

    Multi-wavelength Calibration Procedure for the Pierre Auger Observatory Fluorescence Detectors

    Get PDF
    We present a method to measure the relative spectral response of the Pierre Auger Observatory Fluorescence Detector. The calibration was done at wavelengths of 320, 337, 355, 380 and 405 nm using an end-to-end technique in which the response of all detector components are combined in a single measurement. A xenon flasher and notch-filters were used as the light source for the calibration device. The overall uncertainty is 5%.Comment: Submitted to Astroparticle Physics. V2: section 5.2 extended; author list change

    The DRIFT Dark Matter Experiments

    Full text link
    The current status of the DRIFT (Directional Recoil Identification From Tracks) experiment at Boulby Mine is presented, including the latest limits on the WIMP spin-dependent cross-section from 1.5 kg days of running with a mixture of CS2 and CF4. Planned upgrades to DRIFT IId are detailed, along with ongoing work towards DRIFT III, which aims to be the world's first 10 m3-scale directional Dark Matter detector.Comment: Proceedings of the 3rd International conference on Directional Detection of Dark Matter (CYGNUS 2011), Aussois, France, 8-10 June 201

    Left-Right Symmetry and Supersymmetric Unification

    Get PDF
    The existence of an SU(3) X SU(2)_L X SU(2)_R X U(1) gauge symmetry with g_L = g_R at the TeV energy scale is shown to be consistent with supersymmetric SO(10) grand unification at around 1O^{16} GeV if certain new particles are assumed. The additional imposition of a discrete Z_2 symmetry leads to a generalized definition of R parity as well as highly suppressed Majorana neutrino masses. Another model based on SO(10) X SO(10) is also discussed.Comment: 11 pages, 2 figures not included, UCRHEP-T124, Apr 199
    • …
    corecore