598 research outputs found

    Determination of Head Kinematics from Impact Acceleration Test Data Using Neural Networks

    Get PDF
    This paper presents a study of feed-forward neural network (NN) systems developed to determine the head kinematics of subjects who are exposed to impact accelerations. The neural networks process accelerometer data collected during short-duration impact acceleration tests conducted at the National Biodynamcis Laboratory of the University of New Orleans. During an impact acceleration experiment, the subject sits on the sled chair and a piston gives impetus to the sled to travel down a track. Head data is gathered by an array of nine accelerometers. Two more accelerometers are mounted on the sled. The neural processing systems produce the history of the rotational and translational position, velocity, and acceleration of the origin of the accelerometer array mounted on the mouth. Output produced by a least squares algorithm that uses both photographic and accelerometer raw data are used as a baseline and to provide training data for the neural networks. The main disadvantages of the NNs are their speed, and that statistical information and accurate modeling of the testing system are not required. Results show that the neural networks provide accurate information about the kinematics of the subject even when no photographic data are used

    Determination of Head Kinematics from Impact Acceleration Test Data Using Neural Networks

    Get PDF
    This paper presents a study of feed-forward neural network (NN) systems developed to determine the head kinematics of subjects who are exposed to impact accelerations. The neural networks process accelerometer data collected during short-duration impact acceleration tests conducted at the National Biodynamcis Laboratory of the University of New Orleans. During an impact acceleration experiment, the subject sits on the sled chair and a piston gives impetus to the sled to travel down a track. Head data is gathered by an array of nine accelerometers. Two more accelerometers are mounted on the sled. The neural processing systems produce the history of the rotational and translational position, velocity, and acceleration of the origin of the accelerometer array mounted on the mouth. Output produced by a least squares algorithm that uses both photographic and accelerometer raw data are used as a baseline and to provide training data for the neural networks. The main disadvantages of the NNs are their speed, and that statistical information and accurate modeling of the testing system are not required. Results show that the neural networks provide accurate information about the kinematics of the subject even when no photographic data are used

    OPERATIONAL COSTS OF CANAL COMPANIES AND IRRIGATION DISTRICTS IN THE INTERMOUNTAIN REGION

    Get PDF
    This study reports on the trends of operational costs of farmer owned and operated irrigation enterprises (irrigation districts and canal companies) in five intermountain states. Administrative costs have risen faster then operation and maintenance costs. While salaries of employees have not risen significantly over time, legal costs have greatly escalated.Agribusiness,

    Enabling digital grid for industrial revolution: self-healing cyber resilient platform

    Get PDF
    The key market objectives driving digital grid development are to provide sustainable, reliable and secure network systems that can support variety of applications against any potential cyber attacks. Therefore, there is an urgent demand to accelerate the development of intelligent Software-Defined Networking (SDN) platform that can address the tremendous challenges of data protection for digital resiliency. Modern grid technology tends to adopt distributed SDN controllers for further slicing power grid domain and protect the boundaries of electric data at network edges. To accommodate these issues, this article proposes an intelligent secure SDN controller for supporting digital grid resiliency, considering management coordination capability, to enable self-healing features and recovery of network traffic forwarding during service interruptions. A set of advanced features are employed in grid controllers to configure the network elements in response to possible disasters or link failures. In addition, various SDN topology scenarios are introduced for efficient coordination and configurations of network domains. Finally, to justify the potential advantages of intelligent secure SDN system, a case study is presented to evaluate the requirements of secure digital modern grid networks and pave the path towards the next phase of industry revolution

    Pterygium and Ocular Surface Squamous Neoplasia: Optical Biopsy Using a Novel Autofluorescence Multispectral Imaging Technique

    Get PDF
    In this study, differentiation of pterygium vs. ocular surface squamous neoplasia based on multispectral autofluorescence imaging technique was investigated. Fifty (N = 50) patients with histopathological diagnosis of pterygium (PTG) and/or ocular surface squamous neoplasia (OSSN) were recruited. Fixed unstained biopsy specimens were imaged by multispectral microscopy. Tissue autofluorescence images were obtained with a custom-built fluorescent microscope with 59 spectral channels, each with specific excitation and emission wavelength ranges, suitable for the most abundant tissue fluorophores such as elastin, flavins, porphyrin, and lipofuscin. Images were analyzed using a new classification framework called fused-classification, designed to minimize interpatient variability, as an established support vector machine learning method. Normal, PTG, and OSSN regions were automatically detected and delineated, with accuracy evaluated against expert assessment by a specialist in OSSN pathology. Signals from spectral channels yielding signals from elastin, flavins, porphyrin, and lipofuscin were significantly different between regions classified as normal, PTG, and OSSN (p < 0.01). Differential diagnosis of PTG/OSSN and normal tissue had accuracy, sensitivity, and specificity of 88 ± 6%, 84 ± 10% and 91 ± 6%, respectively. Our automated diagnostic method generated maps of the reasonably well circumscribed normal/PTG and OSSN interface. PTG and OSSN margins identified by our automated analysis were in close agreement with the margins found in the H&E sections. Such a map can be rapidly generated on a real time basis and potentially used for intraoperative assessment

    Comparative Analysis of H2 and H∞ Robust Control Design Approaches for Dynamic Control Systems

    Get PDF
    This paper discusses using H2 and H∞ robust control approaches for designing control systems. These approaches are applied to elementary control system designs, and their respective implementation and pros and cons are introduced. The H∞ control synthesis mainly enforces closed-loop stability, covering some physical constraints and limitations. While noise rejection and disturbance attenuation are more naturally expressed in performance optimization, which can represent the H2 control synthesis problem. The paper also applies these two methodologies to multi-plant systems to study the stability and performance of the designed controllers. Simulation results show that the H2 controller tracks a desirable closed-loop performance, while the H∞ controller guarantees robust stability for the closed-loop system. The validation of the techniques is demonstrated through the robust and performance gamma index, where the H∞ controller achieved a robust gamma index of 0.8591, indicating good robustness and the H2 controller achieved a performance gamma index of 2.1972, indicating a desirable performance. The robust control toolbox of MATLAB is used for simulation purposes. Overall, the paper shows that selecting a suitable, robust control strategy is crucial for designing effective control systems, and the H2 and H∞ robust control approaches are viable options for achieving this goal

    AD-8 for detection of dementia across a variety of healthcare settings

    Get PDF
    BACKGROUND: Dementia assessment often involves initial screening, using a brief tool, followed by more detailed assessment where required. The AD-8 is a short questionnaire, completed by a suitable 'informant' who knows the person well. AD-8 is designed to assess change in functional performance secondary to cognitive change. OBJECTIVES: To determine the diagnostic accuracy of the informant-based AD-8 questionnaire, in detection of all-cause (undifferentiated) dementia in adults. Where data were available, we described the following: the diagnostic accuracy of the AD-8 at various predefined threshold scores; the diagnostic accuracy of the AD-8 for each healthcare setting and the effects of heterogeneity on the reported diagnostic accuracy of the AD-8. SEARCH METHODS: We searched the following sources on 27 May 2014, with an update to 7 June 2018: ALOIS (Cochrane Dementia and Cognitive Improvement Group), MEDLINE (Ovid SP), Embase (Ovid SP), PsycINFO (Ovid SP), BIOSIS Previews (Thomson Reuters Web of Science), Web of Science Core Collection (includes Conference Proceedings Citation Index) (Thomson Reuters Web of Science), CINAHL (EBSCOhost) and LILACS (BIREME). We checked reference lists of relevant studies and reviews, used searches of known relevant studies in PubMed to track related articles, and contacted research groups conducting work on the AD-8 to try to find additional studies. We developed a sensitive search strategy and used standardised database subject headings as appropriate. Foreign language publications were translated. SELECTION CRITERIA: We selected those studies which included the AD-8 to assess for the presence of dementia and where dementia diagnosis was confirmed with clinical assessment. We only included those studies where the AD-8 was used as an informant assessment. We made no exclusions in relation to healthcare setting, language of AD-8 or the AD-8 score used to define a 'test positive' case. DATA COLLECTION AND ANALYSIS: We screened all titles generated by electronic database searches, and reviewed abstracts of potentially relevant studies. Two independent assessors checked full papers for eligibility and extracted data. We extracted data into two-by-two tables to allow calculation of accuracy metrics for individual studies. We then created summary estimates of sensitivity, specificity and likelihood ratios using the bivariate approach and plotting results in receiver operating characteristic (ROC) space. We determined quality assessment (risk of bias and applicability) using the QUADAS-2 tool. MAIN RESULTS: From 36 papers describing AD-8 test accuracy, we included 10 papers. We utilised data from nine papers with 4045 individuals, 1107 of whom (27%) had a clinical diagnosis of dementia. Pooled analysis of seven studies, using an AD-8 informant cut-off score of two, indicated that sensitivity was 0.92 (95% confidence interval (CI) 0.86 to 0.96); specificity was 0.64 (95% CI 0.39 to 0.82); the positive likelihood ratio was 2.53 (95% CI 1.38 to 4.64); and the negative likelihood ratio was 0.12 (95% CI 0.07 to 0.21). Pooled analysis of five studies, using an AD-8 informant cut-off score of three, indicated that sensitivity was 0.91 (95% CI 0.80 to 0.96); specificity was 0.76 (95% CI 0.57 to 0.89); the positive likelihood ratio was 3.86 (95% CI 2.03 to 7.34); and the negative likelihood ratio was 0.12 (95% CI 0.06 to 0.24).Four studies were conducted in community settings; four were in secondary care (one in the acute hospital); and one study was in primary care. The AD-8 has a higher relative sensitivity (1.11, 95% CI 1.02 to 1.21), but lower relative specificity (0.51, 95% CI 0.23 to 1.09) in secondary care compared to community care settings.There was heterogeneity across the included studies. Dementia prevalence rate varied from 12% to 90% of included participants. The tool was also used in various different languages. Among all the included studies there was evidence of risk of bias. Issues included the selection of participants, conduct of index test, and flow of assessment procedures. AUTHORS' CONCLUSIONS: The high sensitivity of the AD-8 suggests it can be used to identify adults who may benefit from further specialist assessment and diagnosis, but is not a diagnostic test in itself. This pattern of high sensitivity and lower specificity is often suited to a screening test. Test accuracy varies by setting, however data in primary care and acute hospital settings are limited. This review identified significant heterogeneity and risk of bias, which may affect the validity of its summary findings

    Customizable, engineered substrates for rapid screening of cellular cues

    Get PDF
    Biophysical cues robustly direct cell responses and are thus important tools for in vitro and translational biomedical applications. High throughput platforms exploring substrates with varying physical properties are therefore valuable. However, currently existing platforms are limited in throughput, the biomaterials used, the capability to segregate between different cues and the assessment of dynamic responses. Here we present a multiwell array (3x8) made of a substrate engineered to present topography or rigidity cues welded to a bottomless plate with a 96-well format. Both the patterns on the engineered substrate and the well plate format can be easily customized, permitting systematic and efficient screening of biophysical cues. To demonstrate the broad range of possible biophysical cues examinable, we designed and tested three multiwell arrays to influence cardiomyocyte, chondrocyte and osteoblast function. Using the multiwell array, we were able to measure different cell functionalities using analytical modalities such as live microscopy, qPCR and immunofluorescence. We observed that grooves (5 µm in size) induced less variation in contractile function of cardiomyocytes. Compared to unpatterned plastic, nanopillars with 127 nm height, 100 nm diameter and 300 nm pitch enhanced matrix deposition, chondrogenic gene expression and chondrogenic maintenance. High aspect ratio pillars with an elastic shear modulus of 16 kPa mimicking the matrix found in early stages of bone development improved osteogenic gene expression compared to stiff plastic. We envisage that our bespoke multiwell array will accelerate the discovery of relevant biophysical cues through improved throughput and variety

    Left atrial pump strain predicts long-term survival after transcatheter aortic valve implantation

    Get PDF
    BACKGROUND This study aims at investigating left atrial (LA) deformation by left atrial reservoir (LARS) and pump strain (LAPS) and its implications for long-term survival in patients with severe aortic stenosis (AS) undergoing transcatheter aortic valve implantation (TAVI). METHODS Speckle tracking echocardiography was performed in 198 patients with severe AS undergoing TAVI. Association of strain parameters with cardiovascular mortality was determined. RESULTS Over a follow-up time of 5 years, 49 patients (24.7%) died. LAPS was more impaired in non-survivors than survivors (P = 0.010), whereas no difference was found for LARS (P = 0.114), LA ejection fraction (P = 0.241), and LA volume index (P = 0.292). Kaplan-Meier analyses yielded a reduced survival probability according to the optimal threshold for LAPS (P = 0.002). A more impaired LAPS was associated with increased mortality risk (HR 1.12 [95% CI 1.02-1.22]; P = 0.014) independent of LVEF, LAVI, age, and sex. Addition of LAPS improved multivariable echocardiographic (LVEF, LAVI) and clinical (age, sex) models with potential incremental value for mortality prediction (P = 0.013 and P = 0.031, respectively). In contrast, LARS and LAVI were not associated with mortality. CONCLUSIONS In patients undergoing aortic valve replacement for severe AS, LAPS was impaired in patients dying during long-term follow-up after TAVI, differentiated survivors from non-survivors, was independently associated with long-term mortality, and yielded potential incremental value for survival prediction after TAVI. LAPS seems useful for risk stratification in severe AS and timely valve replacement
    • …
    corecore