40 research outputs found

    IAEA methodology for on-site end-to-end IMRT/VMAT audits : an international pilot study

    Get PDF
    The IAEA has developed and tested an on-site, end-to-end IMRT/VMAT dosimetry audit methodology for head and neck cases using an anthropomorphic phantom. The audit methodology is described, and the results of the international pilot testing are presented. The audit utilizes a specially designed, commercially available anthropomorphic phantom capable of accommodating a small volume ion chamber (IC) in four locations (three in planning target volumes (PTVs) and one in an organ at risk (OAR)) and a Gafchromic film in a coronal plane for the absorbed dose to water and two-dimensional dose distribution measurements, respectively. The audit consists of a pre-visit and on-site phases. The pre-visit phase is carried out remotely and includes a treatment planning task and a set of computational exercises. The on-site phase aims at comparing the treatment planning system (TPS) calculations with measurements in the anthropomorphic phantom following an end-to-end approach. Two main aspects were tested in the pilot study: feasibility of the planning constraints and the accuracy of IC and film results in comparison with TPS calculations. Treatment plan quality was scored from 0 to 100. Results: Forty-two treatment plans were submitted by 14 institutions from 10 countries, with 79% of them having a plan quality score over 90. Seventeen sets of IC measurement results were collected, and the average measured to calculated dose ratio was 0.988 ± 0.016 for PTVs and 1.020 ± 0.029 for OAR. For 13 film measurement results, the average gamma passing rate was 94.1% using criteria of 3%/3 mm, 20% threshold and global gamma. The audit methodology was proved to be feasible and ready to be adopted by national dosimetry audit networks for local implementation

    Treatment planning systems dosimetry auditing project in Portugal

    Get PDF
    BACKGROUND AND PURPOSE: The Medical Physics Division of the Portuguese Physics Society (DFM_SPF) in collaboration with the IAEA, carried out a national auditing project in radiotherapy, between September 2011 and April 2012. The objective of this audit was to ensure the optimal usage of treatment planning systems. The national results are presented in this paper. MATERIAL AND METHODS: The audit methodology simulated all steps of external beam radiotherapy workflow, from image acquisition to treatment planning and dose delivery. A thorax CIRS phantom lend by IAEA was used in 8 planning test-cases for photon beams corresponding to 15 measuring points (33 point dose results, including individual fields in multi-field test cases and 5 sum results) in different phantom materials covering a set of typical clinical delivery techniques in 3D Conformal Radiotherapy. RESULTS: All 24 radiotherapy centers in Portugal have participated. 50 photon beams with energies 4-18 MV have been audited using 25 linear accelerators and 32 calculation algorithms. In general a very good consistency was observed for the same type of algorithm in all centres and for each beam quality. CONCLUSIONS: The overall results confirmed that the national status of TPS calculations and dose delivery for 3D conformal radiotherapy is generally acceptable with no major causes for concern. This project contributed to the strengthening of the cooperation between the centres and professionals, paving the way to further national collaborations

    Role of quality audits: View from the IAEA

    No full text

    An Australian secondary standard dosimetry laboratory participation in IAEA postal dose audits

    No full text
    For over 30 years, the International Atomic Energy Agency (IAEA) and the World Health Organization (WHO) have jointly monitored activities of secondary standard dosimetry laboratories (SSDLs) through postal dose audits with the aim of achieving consistency in dosimetry throughout the world. The Australian Nuclear Science and Technology Organisation (ANSTO) maintains an SSDL and is a member of the IAEA/WHO SSDL Network. Postal dose audit results at this Australian SSDL from 2001 to 2011 demonstrate the consistency of absorbed dose to water measurements, underpinned by the primary standard maintained at the Australian Radiation Protection and Nuclear Safety Agency (ARPANSA).4 page(s
    corecore