11 research outputs found

    Early postoperative serum S100β levels predict ongoing brain damage after meningioma surgery: a prospective observational study

    Get PDF
    INTRODUCTION: Elevated serum levels of S100β, an astrocyte-derived protein, correlate with unfavourable neurological outcomes following cardiac surgery, neurotrauma, and resuscitation. This study evaluated whether pre-/postoperative serum S100β levels correlate with unfavourable clinical and radiological findings in patients undergoing elective meningioma resection. METHODS: In 52 consecutive patients admitted for meningioma surgery, serum S100β levels were determined upon admission and immediately, 24 hours, and 48 hours after surgery. All patients underwent complete pre- and postoperative neurological examination and mini-mental state examination. Radiological evaluation included preoperative magnetic resonance imaging (MRI) and postoperative computed tomography. Tumour volume, brain edema, and bleeding volume were calculated using BrainSCAN™ software. RESULTS: Preoperative S100β levels did not correlate with the tumour characteristics demonstrated by preoperative MRI (for example, tumour volume, edema volume, ventricular asymmetry, and/or midline shift). Preoperative serum S100β levels (0.065 ± 0.040 μg/l) were significantly lower than the levels measured immediately (0.138 ± 0.081 μg/l), 24 hours (0.142 ± 0.084 μg/l), and 48 hours (0.155 ± 0.119 μg/l) postoperatively (p < 0.0001). Significantly greater postcraniotomy S100β levels were observed with prolonged surgery (p = 0.039), deterioration in the mini-mental state examination (p = 0.005, 0.011, and 0.036 for pre versus immediate, 24 hours, and 48 hours postsurgery, respectively), and with postoperative brain computed tomography evidence of brain injury; bleeding was associated with higher serum S100β levels at 24 and 48 hours after surgery (p = 0.046, 95% confidence interval [CI] -0.095 to -0.001 and p = 0.034, 95% CI -0.142 to -0.006, respectively) as was the presence of midline shift (p = 0.005, 95% CI -0.136 to -0.025 and p = 0.006, 95% CI -0.186 to -0.032, respectively). Edema was associated with higher serum S100β levels immediately (p = 0.022, 95% CI -0.092 to -0.007) and at 48 hours after surgery (p = 0.017, 95% CI -0.142 to -0.026). The degree of elevation in S100β levels at 24 and 48 hours after surgery also correlated with the severity of midline shift and edema. CONCLUSION: In patients with meningioma, serum S100β levels perform poorly as an indicator of tumour characteristics but may suggest ongoing postcraniotomy injury. Serum S100β levels may serve as a potentially useful early marker of postcraniotomy brain damage in patients undergoing elective meningioma resection

    Serum S100B levels after meningioma surgery: A comparison of two laboratory assays

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>S100B protein is a potential biomarker of central nervous system insult. This study quantitatively compared two methods for assessing serum concentration of S100B.</p> <p>Methods</p> <p>A prospective, observational study performed in a single tertiary medical center. Included were fifty two consecutive adult patients undergoing surgery for meningioma that provided blood samples for determination of S100B concentrations. Eighty samples (40 pre-operative and 40 postoperative) were randomly selected for batch testing. Each sample was divided into two aliquots. These were analyzed by ELISA (Sangtec) and a commercial kit (Roche Elecsys<sup>®</sup>) for S100B concentrations. Statistical analysis included regression modelling and Bland-Altman analysis.</p> <p>Results</p> <p>A parsimonious linear model best described the prediction of commercial kit values by those determined by ELISA (y = 0.045 + 0.277*x, x = ELISA value, R<sup>2 </sup>= 0.732). ELISA measurements tended to be higher than commercial kit measurements. This discrepancy increased linearly with increasing S100B concentrations. At concentrations above 0.7 μg/L the paired measurements were consistently outside the limits of agreement in the Bland-Altman display. Similar to other studies that used alternative measurement methods, sex and age related differences in serum S100B levels were not detected using the Elecsys<sup>® </sup>(p = 0.643 and 0.728 respectively).</p> <p>Conclusion</p> <p>Although a generally linear relationship exists between serum S100B concentrations measured by ELISA and a commercially available kit, ELISA values tended to be higher than commercial kit measurements particularly at concentrations over 0.7 μg/L, which are suggestive of brain injury. International standardization of commercial kits is required before the predictive validity of S100B for brain damage can be effectively assessed in clinical practice.</p

    Spine Robot-Assisted Vertebral Body Augmentation A Radiation Reduction Tool

    No full text
    Study Design. Retrospective. Objective. To assess radiation exposure time during robot-guided vertebral body augmentation compared with other published fi ndings. Summary of Background Data. Rising incidence of vertebral compression fractures in the aging population result in widespread use of vertebral body cement augmentation with signifi cant radiation exposure to the surgeon, operating room staff, and patient. Radiation exposure leads to higher cancer rates among orthopedic and spine surgeons and patients. Methods. Thirty-three patients with 60 vertebral compression fractures underwent robot-guided vertebral body augmentation performed by 2 surgeons simultaneously injecting cement at 2 levels under pulsed fl uoroscopy. The age of patients was in the range from 29 to 92 (mean, 67 yr). One to 6 vertebrae were augmented per case (average 2). Twenty-fi ve patients had osteoporotic fractures and 8 had pathological fractures. Robotic guidance data included execution rate, accuracy of guidance, total surgical time, and time required for robotic guidance. Radiation-related data included the average preoperative computed tomographic effective dose, radiation time for calibration, registration, placement of Kirschner wires, and total procedure radiation time. Radiation time per level and surgeon&apos;s exposure were calculated. Results. Kyphoplasty was performed in 15 patients (1 sacroplasty), vertebroplasty in 13, and intravertebral expanding implants in 5. The average preoperative computed tomographic effective dose was 50 mSv (18-81). Average operative time was 118 minutes (49-350). Mean robotic guidance took 36 minutes. Average operative radiation time was 46.1 seconds per level (33-160). Average exposure time From the
    corecore