87 research outputs found

    Measurements of Compton Scattered Transition Radiation at High Lorentz Factors

    Get PDF
    X-ray transition radiation can be used to measure the Lorentz factor of relativistic particles. Standard transition radiation detectors (TRDs) typically incorporate thin plastic foil radiators and gas-filled x-ray detectors, and are sensitive up to \gamma ~ 10^4. To reach higher Lorentz factors (up to \gamma ~ 10^5), thicker, denser radiators can be used, which consequently produce x-rays of harder energies (>100 keV). At these energies, scintillator detectors are more efficient in detecting the hard x-rays, and Compton scattering of the x-rays out of the path of the particle becomes an important effect. The Compton scattering can be utilized to separate the transition radiation from the ionization background spatially. The use of conducting metal foils is predicted to yield enhanced signals compared to standard nonconducting plastic foils of the same dimensions. We have designed and built a Compton Scatter TRD optimized for high Lorentz factors and exposed it to high energy electrons at the CERN SPS. We present the results of the accelerator tests and comparisons to simulations, demonstrating 1) the effectiveness of the Compton Scatter TRD approach; 2) the performance of conducting aluminum foils; and 3) the ability of a TRD to measure energies approximately an order of magnitude higher than previously used in very high energy cosmic ray studies.X-ray transition radiation can be used to measure the Lorentz factor of relativistic particles. Standard transition radiation detectors (TRDs) typically incorporate thin plastic foil radiators and gas-filled x-ray detectors, and are sensitive up to \gamma ~ 10^4. To reach higher Lorentz factors (up to \gamma ~ 10^5), thicker, denser radiators can be used, which consequently produce x-rays of harder energies (>100 keV). At these energies, scintillator detectors are more efficient in detecting the hard x-rays, and Compton scattering of the x-rays out of the path of the particle becomes an important effect. The Compton scattering can be utilized to separate the transition radiation from the ionization background spatially. The use of conducting metal foils is predicted to yield enhanced signals compared to standard nonconducting plastic foils of the same dimensions. We have designed and built a Compton Scatter TRD optimized for high Lorentz factors and exposed it to high energy electrons at the CERN SPS. We present the results of the accelerator tests and comparisons to simulations, demonstrating 1) the effectiveness of the Compton Scatter TRD approach: 2) the performance of conducting aluminum foils: and 3) the ability of a TRD to measure energies approximately an order of magnitude higher than previously used in very high energy cosmic ray studies

    A conceptual basis for surveying fouling communities at exposed and protected sites at sea: Feasible designs with exchangeable test bodies for in-situ biofouling collection

    Get PDF
    The enhanced inertia load caused by biofouling on device components, such as the foundations of wind turbines or other structures at sea, modifies the hydrodynamic properties, and increases the stress to structures, predominantly in upper water layers with high impact from wave dynamics. This compromises the stability, functioning, operation as well as the durability of these devices especially in exposed environments. A main challenge is the quantification of the impact of hydrodynamic forces on irregular bodies being overgrown by soft- and hard-bodied biofouling organisms. Therefore, test bodies from the upper 1–5 m water depth and thus exposed to the strongest wave actions close to the surface shall be overgrown by biofouling and used in measurement trials in a wave and current flume. These measurements shall shed light on the varying roughness and its influence on the load bearing capacity of foundation piles. Consequently, the main aims of the present work were the development of two independent test stations as holding devices for artificial test bodies for the collection of biofouling organisms during field studies: a carrying unit floating at the surface in an exposed area (System A) and a sampling device with access from a land-based facility (System B). Both systems are relatively easy to access, exhibit straightforward handling, and are reasonable cost-effective. A Test Body Support Unit (TBSU, System A) was designed and mounted on a spare buoy to carry the test bodies (cylinders), which serve as substrate for the fouling. The system was sufficiently robust to withstand several periods of rough sea conditions over the first two years. This system can only be accessed by vessels. System B (MareLift) provided the robustness and functionality needed for areas exhibiting harsh conditions but can be operated from land. The here used test bodies (steel panels) exhibited a sound basis for the monitoring of succession processes in the biofouling development. System B offered the possibility to analyse two habitats (intertidal and subtidal) and revealed clear differences in the composition and development of their fouling communities. Overall, both systems provide advantages in obtaining standardized biofouling samples compared to previous approaches. Such test stations play an important role in the risk management of marine sectors as they could help characterising biofouling communities over different geographical areas. System A and B provide a sound basis for biofouling research but potentially also for other potential research approaches in exposed areas as they provide space for future developments

    Upturn observed in heavy nuclei to iron ratios by the ATIC-2 experiment

    Get PDF
    The ratios of fluxes of heavy nuclei from sulfur (Z=16) to chromium (Z=24) to the flux of iron were measured by the ATIC-2 experiment. The ratios are decreasing functions of energy from 5 GeV/n to approximately 80 GeV/n, as expected. However, an unexpected sharp upturn in the ratios are observed for energies above 100 GeV/n for all elements from Z=16 to Z=24. Similar upturn but with lower amplitude was also discovered in the ATIC-2 data for the ratio of fluxes of abundant even nuclei (C, O, Ne, Mg, Si) to the flux of iron. Therefore the spectrum of iron is significantly different from the spectra of other abundant even nuclei.Comment: 4 pages, LaTeX2e, a paper for 23rd European Cosmic Ray Symposium (2012

    Relative abundances of cosmic ray nuclei B-C-N-O in the energy region from 10 GeV/n to 300 GeV/n. Results from ATIC-2 (the science flight of ATIC)

    Full text link
    The ATIC balloon-borne experiment measures the energy spectra of elements from H to Fe in primary cosmic rays from about 100 GeV to 100 TeV. ATIC is comprised of a fully active bismuth germanate calorimeter, a carbon target with embedded scintillator hodoscopes, and a silicon matrix that is used as the main charge detector. The silicon matrix produces good charge resolution for protons and helium but only partial resolution for heavier nuclei. In the present paper, the charge resolution of ATIC was improved and backgrounds were reduced in the region from Be to Si by using the upper layer of the scintillator hodoscope as an additional charge detector. The flux ratios of nuclei B/C, C/O, N/O in the energy region from about 10 GeV/nucleon to 300 GeV/nucleon obtained from this high-resolution, high-quality charge spectra are presented, and compared with existing theoretical predictions.Comment: 4 pages,2 figures, a paper for 30-th International Cosmic Rays Conferenc

    The Electron Calorimeter (ECAL) Long Duration Balloon Experiment

    Get PDF
    Accurate measurements of the cosmic ray electron energy spectrum in the energy region 50 GeV to greater than 1 TeV may reveal structure caused by the annihilation of exotic dark matter particles and/or individual cosmic ray sources. Here we describe a new long duration balloon (LDB) experiment, ECAL, optimized to directly measure cosmic ray electrons up to several TeV. ECAL includes a double layer silicon matrix, a scintillating optical fiber track imager, a neutron detector and a fully active calorimeter to identify more than 90% of the incident electrons with an energy resolution of about 1.7% while misidentifying only 1 in 200,000 protons and 0.8% of secondary gamma rays as electrons. Two ECAL flights in Antarctica are planned for a total exposure of 50 days with the first flight anticipate for December 2009

    Relative Abundances of Cosmic Ray Nuclei B-C-N-O in the Energy Region from 10 GeV/n to 300 GeV/n. Results from the Science Flight of the ATIC

    Get PDF
    The ATIC balloon-borne experiment measures the energy spectra of elements from H to Fe in primary cosmic rays from about 100 GeV to 100 TeV. ATIC is comprised of a fully active bismuth germanate calorimeter, a carbon target with embedded scintillator hodoscopes, and a silicon matrix that is used as a main charge detector. The silicon matrix produces good charge resolution for the protons and helium but only a partial resolution for heavier nuclei. In the present paper a charge resolution of ATIC device was essentially improved and backgrounds were reduced in the region from Be to Si by means of the upper layer of the scintillator hodoscope that was used as an additional charge detector together with the silicon matrix. The flux ratios of nuclei B/C, O/C, N/C in the energy region from about 10 GeV/nucleon to 300 GeV/nucleon that were obtained from new high-resolution and high-quality charge spectra of nuclei are presented. The results are compared with existing theoretical predictions

    The Orbiting Astrophysical Spectrometer In Space (OASIS)

    Get PDF
    The Orbiting Astrophysical Observatory In Space (OASIS) is an Advanced Concept currently under study at NASA as a mission for the next decade. The goal of the OASIS mission is to identify a local site or sites where galactic cosmic rays (GCR) originate and are accelerated. The mission will also allow GCR data to be used to investigate how elements are made and distributed in the galaxy and to improve our understanding of supernovae and the nucleosynthesis of the heavy elements. OASIS consists of two instruments that provide complementary data on the location and nature of the source(s) through investigating the composition of ultra-heavy nuclei ( ) and the energy spectrum of electrons. In particular OASIS will measure the relative abundances in the actinide group ( ) to determine the age of the -process material in GCRs. The presence of young r-process material would indicate that GCRs are a sample of the interstellar medium in OB associations. OASIS will measure the electron spectrum to 10 TeV. The energy where this spectrum ends will tell us the distance to the nearest GCR source(s). OASIS will look for spectral features and anisotropy in the high energy electron spectrum that are expected to appear when only a few of the nearest astrophysical sources can contribute to the electron flux. Spectral features may also suggest dark matter decay products. We anticipate that these measurements will lead to the identification of the nearest cosmic ray electron source and provide a crucial test of the OB association model for the origin of GCR nuclei

    Search for antihelium in cosmic rays

    Get PDF
    The Alpha Magnetic Spectrometer (AMS) was flown on the space shuttle Discovery during flight STS-91 in a 51.7 degree orbit at altitudes between 320 and 390 km. A total of 2.86 * 10^6 helium nuclei were observed in the rigidity range 1 to 140 GV. No antihelium nuclei were detected at any rigidity. An upper limit on the flux ratio of antihelium to helium of < 1.1 * 10^-6 is obtained.Comment: 18 pages, Latex, 9 .eps figure

    Energy Spectra of Abundant Nuclei of Primary Cosmic Rays from the Data of ATIC-2 Experiment: Final Results

    Get PDF
    The final results of processing the data from the balloon-born experiment ATIC-2 (Antarctica, 2002-2003) for the energy spectra of protons and He, C, O, Ne, Mg, Si, and Fe nuclei, the spectrum of all particles, and the mean logarithm of atomic weight of primary cosmic rays as a function of energy are presented. The final results are based on improvement of the methods used earlier, in particular, considerably increased resolution of the charge spectrum. The preliminary conclusions on the significant difference in the spectra of protons and helium nuclei (the proton spectrum is steeper) and the non-power character of the spectra of protons and heavier nuclei (flattening of carbon spectrum at energies above 10 TeV) are confirmed. A complex structure of the energy dependence of the mean logarithm of atomic weight is found.Comment: 4 pages, a paper for 30th Russian Cosmic Ray Conference (2008, St. Petersburg
    • …
    corecore