22 research outputs found

    Chromatic-achromatic perimetry in four clinic cases: Glaucoma and diabetes

    Get PDF
    Background: Some diseases that affect the visual system may show loss of chromatic-achromatic sensitivity before obvious physical signs appear in the usual examination of the eye's posterior segment. A perimetric study has been conducted with four typical patients with glaucoma and diabetes, at different stages of the disease. Materials and Methods: In addition to the standard white-on-white (standard automated perimetry [SAP]), a test battery has been used to study patient's contrast sensitivity, using stimuli with different chromatic, spatial, and temporal content (multichannel perimetry). The choice of stimuli tries to maximize the response of different visual mechanisms: Achromatic (parvocellular and magnocellular origin); chromatic red-green (parvocellular origin); and chromatic blue-yellow (koniocellular origin). Results: The results seem to indicate losses in the achromatic-parvocellular perimetry and both chromatic perimetry tests, undetected by conventional SAP. Conclusions: Our results illustrate that our patients without visible retinal alterations show signs of suspicion in multichannel perimetry.The ATD multichannel perimeter was built thanks to the support of the Spanish Ministery for Science and Technology Grants DPI2000-0116-P4-02 and PTR 1995-0909-OP, in collaboration with INDUSTRIAS DE OPTICA SA (San Cugat del Vallés, Spain)

    Intrasession repeatability of refractive and ocular aberrometric measurements obtained using a multidiagnostic device in healthy eyes

    Get PDF
    Purpose: To evaluate the intrasession repeatability of refractive and ocular aberrometric measurements obtained using a new multidiagnostic device in healthy eyes. Patients and methods: A total of 107 eyes of 107 patients, age ranging from 23 to 65 years, were enrolled in this study. A complete eye examination was performed in all eyes, including an ocular examination using the VX120 system. Three consecutive measurements were obtained using this device to assess the intrasession repeatability of different refractive and ocular aberrometric parameters. The within-subject standard deviation (Sw), intrasubject precision (1.96×Sw), and intraclass correlation coefficient (ICC) were calculated. Results: Sw and intrasubject precision for refractive data were below 0.12 and 0.20 D, respectively, in all cases. The ICC ranged from 0.947 for the J45 power vector component to 0.997 for the sphere. Concerning aberrometric measurements Sw and intrasubject precision values were below 0.05 µm and 0.10 µm, respectively. Likewise, the ICC ranged from 0.805 for the quadrafoil root mean square to 0.954 for the primary spherical aberration. Poor correlations were found between most of the refractive parameters and their Sw (–0.033≤r≤0.053, p≥0.064). Moderate and significant positive correlations were found between the magnitude of the aberrometric parameters evaluated and their Sw (r≥0.446, p<0.001). Conclusion: The new multidiagnostic device evaluated is able to provide consistent measurements of refraction and ocular aberrations in healthy eyes. Future studies should confirm if this consistency is also observed in highly aberrated eyes

    Corneal Topographic and Aberrometric Measurements Obtained with a Multidiagnostic Device in Healthy Eyes: Intrasession Repeatability

    Get PDF
    Purpose. To evaluate the intrasession repeatability of corneal curvature, eccentricity, and aberrometric measurements obtained with a multidiagnostic device in healthy eyes. Methods. This study enrolled 107 eyes of 107 patients ranging in age from 23 to 65 years. All of them underwent a complete anterior segment examination with the VX120 system (Visionix-Luneau Technologies, Chartres, France). Three consecutive measurements were obtained. The within-subject standard deviation (Sw), intrasubject precision (1.96xSw), and intraclass correlation coefficient (ICC) were calculated. Results. All Sw for corneal power measurements were below 0.26 D, with ICC above 0.982. The Sw for corneal astigmatism at different areas (3, 5, and 7 mm) was below 0.21 D, with ICC above 0.913. Concerning the axis of astigmatism, its Sw was below 11.27°, with ICC above 0.975. The Sw and ICC for corneal eccentricity were 0.067 and 0.957, respectively. The Sw and ICC for high-order aberration root mean square (RMS) were 0.048 µm and 0.901, respectively. For 3rd- and 4th-order aberrometric parameters, all Sw were below 0.037 µm and all ICC were higher than 0.84, except for quadrafoil RMS (ICC: 0.689). Conclusions. The multidiagnostic device evaluated is able to provide consistent measurements of corneal power, eccentricity, and third- and fourth-order aberrations in healthy eyes

    Intrasession repeatability of ocular anatomical measurements obtained with a multidiagnostic device in healthy eyes

    Get PDF
    Background: To evaluate the intrasession repeatability of anterior chamber depth (ACD), central (CCT) and peripheral corneal thickness (PCT), white-to-white diameter (WTW), and irido-corneal angle (IA) measurements obtained with a multidiagnostic device in healthy eyes. Methods: A total of 107 eyes of 107 patients ranging in age from 23 to 65 years were examined with the VX120 system (Visionix-Luneau Technologies). Three consecutive measurements were obtained with this device to assess the intrasession repeatability of ACD, CCT, PCT at different nasal and temporal locations, WTW, and nasal and temporal IA. Data analysis included the calculation of within-subject standard deviation (Sw), intrasubject precision (1.96xSw), coefficient of variation (CV) and intraclass correlation coefficient (ICC). Results: The Sw and CV for ACD was 0.03 mm and 1.16%, respectively, with an ICC of 0.992. The Sw values for central and peripheral pachymetric measurements were below 9 μm, with CV of less than 1.6% and ICC of 0.976 or higher. For IA measurements, Sw values of 0.84 or lower were found, with a CV between 1 and 2%, and an ICC of more than 0.970. The Sw for WTW was 0.24 mm and the CV was 1.95%. No statistically significant correlations were found between any anatomical parameter evaluated and their Sw and CV values associated (−0.220 ≤ r ≤ 0.204, p ≥ 0.125). Conclusions: The VX120 system is able to provide repeatable measurements of anatomical parameters in healthy eyes. Inter-observer repeatability should be evaluated in future studies

    Puesta en marcha y coordinación del Máster en Optometría Avanzada y Salud Visual

    Get PDF
    Durante el curso 2015-2016 se va a implantar, en la Universidad de Alicante, el máster en Optometría Avanzada y Salud Visual, que fue aprobado por la ANECA en diciembre del 2014. Con el fin de coordinar las actividades docentes de cada una de las asignaturas del máster y dentro del Proyecto de Redes de Investigación en Docencia Universitaria 2014-2015, se ha creado una red formada por todos los profesores coordinadores de las asignaturas que constituyen el plan de estudios y que han participado en la realización de la memoria de dicho máster. En esta red se pretende la coordinación entre todas las asignaturas para organizar y desarrollar sus actividades con el fin de conseguir una buena distribución de la carga docente y un mejor aprovechamiento por parte del alumno de la docencia recibida. Por otra parte, dado que en este máster participan varias empresas del sector óptico y clínicas oftalmológicas es necesario determinar qué actividades propuestas por las empresas y clínicas se van a incluir en cada asignatura y planificarlas adecuadamente

    Coordinación docente del cuarto curso del Grado de Óptica y Optometría y el Máster en Optometría Clínica y Visión

    Get PDF
    El Máster en Optometría Clínica y Visión comenzó a impartirse en la Universidad de Alicante en el curso 2010-2011. Durante estos tres años los alumnos que han accedido a él, han sido, en su mayoría, Diplomados en Óptica y Optometría. Actualmente se está impartiendo el Grado de Óptica y Optometría, por lo que a partir del curso 2013-2014 los alumnos que accedan al Máster serán mayoritariamente graduados. Teniendo en cuenta que en el Grado de Óptica y Optometría se han añadido asignaturas (respecto a la Diplomatura), que incluyen temas coincidentes con asignaturas del Máster, es necesario modificar y reorientar algunas de las guías docentes de las asignaturas del Máster. En este sentido el objetivo principal de esta red ha sido la coordinación entre los profesores de las diferentes asignaturas para actualizar y/o reorientar las guías docentes de las asignaturas del Máster en Optometría Clínica y Visión, evitando solapamientos con las asignaturas de 4º curso del Grado de Óptica y Optometría

    Trabajo de coordinación para la implantación del Máster en Optometría Avanzada y Salud Visual

    Get PDF
    Durante el curso 2013-2014 la Universidad de Alicante ha propuesto la implantación del Master en Optometría Avanzada y Salud Visual, dicha solicitud está siendo actualmente evaluada por la ANECA. Con el fin de coordinar la docencia de este Máster y dentro del Proyecto de Redes de Investigación en Docencia Universitaria 2013-2014, se ha creado una red formada por todos los profesores que han participado en la elaboración del plan de estudios. En esta red esta red se pretende la coordinación entre las distintas asignaturas para elaborar las guías docentes a partir de los datos de las fichas enviadas a la ANECA. Por otra parte también se ha modificado la memoria atendiendo a las alegaciones realizadas por la ANECA. Y se han desarrollado los contenidos, la metodología de las distintas actividades propuestas con el fin de asegurar la consecución de las competencias previstas

    Seguimiento del Máster en Optometría Avanzada y Salud Visual

    Get PDF
    Durante el curso 2015-16 se ha implantado en la Universidad de Alicante el Máster en Optometría Avanzada y Salud Visual. Dicho máster pretende ampliar los conocimientos de los graduados en Óptica y Optometría y mostrar los nuevos avances en las materias de la Óptica y Optometría. Por ello se ha desarrollado un plan de estudios con una gran cantidad de asignaturas, tanto obligatorias como optativas. Con el fin de analizar el primer año de funcionamiento de éste máster se plantea una red que permita evaluar los resultados y el grado de satisfacción de alumnos, profesores y demás participantes, así como plantear posibles mejoras. Con este fin se han realizado reuniones con los miembros de la red en las que se han elaborado las herramientas que permitan analizar el primer año del Máster en Optometría Avanzada y Salud Visual. Concretamente se han diseñado encuestas para los alumnos y para cada una de las asignaturas, cuyos resultados han sido evaluados a lo largo de la red

    Puesta en marcha del Máster en Optometría Avanzada y Salud Visual

    Get PDF
    El Máster en Optometría Avanzada y Salud Visual de la Universidad de Alicante pretende ampliar los conocimientos de los graduados en Óptica y Optometría y mostrar los nuevos avances en las materias de la Óptica y Optometría. Para ello se ha diseñado un máster formado por una gran cantidad de asignaturas tanto obligatorias como optativas. Con el fin de analizar el primer año de funcionamiento de éste máster se plantea una red que permita evaluar los resultados y el grado de satisfacción de alumnos, profesores y demás participantes, así como plantear posibles mejoras Con este fin se han realizado reuniones con los miembros de la red en las que se han elaborado las herramientas que permitan analizar el primer año del Máster en Optometría Avanzada y Salud Visual, concretamente se han diseñado encuestas para los alumnos para cada una de las asignaturas, tanto de primer como de segundo cuatrimestre y cuyos resultados serán evaluados a lo largo de la red