112 research outputs found

    DEVELOPMENT AND VALIDATION OF SPECTROPHOTOMETRIC AND ION PAIR CHROMATOGRAPHIC TECHNIQUE FOR ESTIMATION OF VALSARTAN AND HYDROCHLOROTHIAZIDE

    Get PDF
    Two new simple, sensitive, rapid, accurate and reproducible methods (UV-spectrophotometric and ion pair chromatography) have been developed for simultaneous estimation of valsartan (VAL) and hydrochlrothiazide (HCTZ) from their tablet dosage form. The first method involves multiwavelength spectrophotometric method (Method 1) in which interference of HCTZ at 245nm (wavelength for estimation of VAL) was removed by recording absorbance difference at 245nm and 301 nm whereas HCTZ was estimated directly from its absorbance at 316 nm at which VAL shows no absorbance. Linearity of the response was demonstrated by VAL in the concentration range of 5-45 g/ml with a square correlation coefficient (r2) of 0.9998. Linearity of the response was demonstrated by HCTZ in the concentration range of 2-18 g/ml with a square correlation coefficient (r2) of 0.9994. The second method utilizes ion pair chromatography (Method 2) on a HIQ sil ODS column (250 mm* 4.6 mm i.d.) using methanol: 0.0025 M orthophosphoric acid: (70:30 by volume) having pH 4.6: 0.1% hexane sulphonic acid as mobile phase with UV detection at 259nm over concentration range for VAL is 240-0 μg/ml, and for HCTZ is 75-0μg/ml. Losartan potassium was used as the internal standard. The suggested procedures were checked using laboratory prepared mixtures and were applied successfully for the analysis of their tablet dosage form. The results of analysis were statistically analysed. Both the methods were validated as per ICH Q2B guideline

    Importance of urine sodium dithionite test in paraquat poisoning: a case study

    Get PDF
    Suicidal tendencies are one of the major social problems worldwide. It is equally seen in Indian population. Organo-phosphorus compounds are usually preferred because of their easy availability. Paraquat is one of the lesser known herbicide agent, which is not an OP compound. It is highly toxic and causes damage to the lungs, liver and kidneys. Occurrence of paraquat poisoning is rare, but has very high mortality rate. Here we report one such case which was earlier misdiagnosed as organo-phosphorus poisoning, but diagnosed later by qualitative urine sodium dithionite test. It is a simple test for early diagnosis of paraquat poisoning. It is recommended to performing this test in all suspected cases of oral poisoning

    Oxidative stress versus inflammation, a better predictor of cardiovascular disease risk in polycystic ovary syndrome

    Get PDF
    Background: Polycystic ovary syndrome (PCOS) is also known as hyperandrogenic anovulation (HA) or Stein-Leventhal syndrome. PCOS has a diverse range of causes that are not entirely understood, but there is evidence that it is largely a genetic disease. Aim of the study was to evaluate better predictor of cardiovascular disease risk in women with polycystic ovary syndrome.Methods: 50 diagnosed patients of PCOS and 50 age matched healthy females were included in this study. Cases were diagnosed based on new Rotterdam criteria formulated by the American Society for Reproductive Medicine (ASRM). Fasting Blood samples were collected. Serum High sensitivity-C reactive protein (hs-CRP) and Malondialdehyde (MDA) were estimated.Results: Results were analyzed using unpaired t-test and p-value was calculated. Statistically non-significant increased levels of serum hs-CRP in PCOS cases as compared with controls were observed. MDA was found to be significantly increased in cases as compared to controls. ROC curve analysis shows MDA as a more specific predictor of cardiovascular disease risk in PCOS compared to hs-CRP.Conclusions: Increase in the serum MDA level indicates increased formation of reactive oxygen species and lipid peroxidation which leads to increased oxidative stress and this may increase cardiovascular disease risk in PCOS. hs-CRP a marker of chronic inflammation was not significantly increased in PCOS

    Detonating Cord for Flux Compression Generation using Electrical Detonator No. 33

    Get PDF
    The paper highlights the use of electrical detonators for magnetic flux compression generator applications which requires synchronisation of two events with precise time delay of tens of ms and jitter within a few ms. These requirements are generally achieved by exploding bridge wire type detonators which are difficult to develop and are not commercially available. A technique has been developed using commercially available electrical detonator no. 33 to synchronise between peak of seed current in stator coil and detonation of explosive charge in armature. In present experiments, electrical signal generated by self-shorting pin due to bursting of electrical detonator has been used to trigger the capacitor discharge and the detonating cord of known length has been used to incorporate predetermined delay to synchronise the events. It has been demonstrated that using electrical detonator and known length of detonating cord, the two events can be synchronised with predetermined delay between 31 and 251 ms with variation of ± 0.5ms. The technique developed is suitable for defence applications like generation of high power microwaves using explosive driven magnetic flux compression generators.Defence Science Journal, 2011, 61(1), pp.19-24, DOI:http://dx.doi.org/10.14429/dsj.61.3

    Ultrafast optical generation of coherent phonons in CdTe1-xSex quantum dots

    Full text link
    We report on the impulsive generation of coherent optical phonons in CdTe0.68Se0.32 nanocrystallites embedded in a glass matrix. Pump probe experiments using femtosecond laser pulses were performed by tuning the laser central energy to resonate with the absorption edge of the nanocrystals. We identify two longitudinal optical phonons, one longitudinal acoustic phonon and a fourth mode of a mixed longitudinal-transverse nature. The amplitude of the optical phonons as a function of the laser central energy exhibits a resonance that is well described by a model based on impulsive stimulated Raman scattering. The phases of the coherent phonons reveal coupling between different modes. At low power density excitations, the frequency of the optical coherent phonons deviates from values obtained from spontaneous Raman scattering. This behavior is ascribed to the presence of electronic impurity states which modify the nanocrystal dielectric function and, thereby, the frequency of the infrared-active phonons

    Swift Heavy Ion Induced Modification Studies of C60 Thin Films

    Full text link
    Modification induced by 110 MeV Ni ion irradiated thin film samples of C60 on Si and quartz substrates were studied at various fluences. The pristine and irradiated samples were investigated using Raman spectroscopy, electrical conductivity and optical absorption spectroscopy. The Raman data and band gap measurements indicate that swift ions at low fluences result in formations that involve multiple molecular units like dimer or polymer. High fluence irradiation resulted in sub-molecular formations and amorphous semiconducting carbon, indicating overall damage of the fullerene molecules. These sub-molecular units have been identified with nanocrystalline diamond and nanocrystalline graphite like formations.Comment: 7 pages, 29 references and 9 figures submitted to J. Appl. Phy

    Bio-nanotechnology application in wastewater treatment

    Get PDF
    The nanoparticles have received high interest in the field of medicine and water purification, however, the nanomaterials produced by chemical and physical methods are considered hazardous, expensive, and leave behind harmful substances to the environment. This chapter aimed to focus on green-synthesized nanoparticles and their medical applications. Moreover, the chapter highlighted the applicability of the metallic nanoparticles (MNPs) in the inactivation of microbial cells due to their high surface and small particle size. Modifying nanomaterials produced by green-methods is safe, inexpensive, and easy. Therefore, the control and modification of nanoparticles and their properties were also discussed

    Linear and Branched Glyco-Lipopeptide Vaccines Follow Distinct Cross-Presentation Pathways and Generate Different Magnitudes of Antitumor Immunity

    Get PDF
    Glyco-lipopeptides, a form of lipid-tailed glyco-peptide, are currently under intense investigation as B- and T-cell based vaccine immunotherapy for many cancers. However, the cellular and molecular mechanisms of glyco-lipopeptides (GLPs) immunogenicity and the position of the lipid moiety on immunogenicity and protective efficacy of GLPs remain to be determined.We have constructed two structural analogues of HER-2 glyco-lipopeptide (HER-GLP) by synthesizing a chimeric peptide made of one universal CD4(+) epitope (PADRE) and one HER-2 CD8(+) T-cell epitope (HER(420-429)). The C-terminal end of the resulting CD4-CD8 chimeric peptide was coupled to a tumor carbohydrate B-cell epitope, based on a regioselectively addressable functionalized templates (RAFT), made of four alpha-GalNAc molecules. The resulting HER glyco-peptide (HER-GP) was then linked to a palmitic acid moiety, attached either at the N-terminal end (linear HER-GLP-1) or in the middle between the CD4+ and CD8+ T cell epitopes (branched HER-GLP-2). We have investigated the uptake, processing and cross-presentation pathways of the two HER-GLP vaccine constructs, and assessed whether the position of linkage of the lipid moiety would affect the B- and T-cell immunogenicity and protective efficacy. Immunization of mice revealed that the linear HER-GLP-1 induced a stronger and longer lasting HER(420-429)-specific IFN-gamma producing CD8(+) T cell response, while the branched HER-GLP-2 induced a stronger tumor-specific IgG response. The linear HER-GLP-1 was taken up easily by dendritic cells (DCs), induced stronger DCs maturation and produced a potent TLR- 2-dependent T-cell activation. The linear and branched HER-GLP molecules appeared to follow two different cross-presentation pathways. While regression of established tumors was induced by both linear HER-GLP-1 and branched HER-GLP-2, the inhibition of tumor growth was significantly higher in HER-GLP-1 immunized mice (p<0.005).These findings have important implications for the development of effective GLP based immunotherapeutic strategies against cancers

    Synthetic Nanoparticles for Vaccines and Immunotherapy

    Get PDF
    The immune system plays a critical role in our health. No other component of human physiology plays a decisive role in as diverse an array of maladies, from deadly diseases with which we are all familiar to equally terrible esoteric conditions: HIV, malaria, pneumococcal and influenza infections; cancer; atherosclerosis; autoimmune diseases such as lupus, diabetes, and multiple sclerosis. The importance of understanding the function of the immune system and learning how to modulate immunity to protect against or treat disease thus cannot be overstated. Fortunately, we are entering an exciting era where the science of immunology is defining pathways for the rational manipulation of the immune system at the cellular and molecular level, and this understanding is leading to dramatic advances in the clinic that are transforming the future of medicine.1,2 These initial advances are being made primarily through biologic drugs– recombinant proteins (especially antibodies) or patient-derived cell therapies– but exciting data from preclinical studies suggest that a marriage of approaches based in biotechnology with the materials science and chemistry of nanomaterials, especially nanoparticles, could enable more effective and safer immune engineering strategies. This review will examine these nanoparticle-based strategies to immune modulation in detail, and discuss the promise and outstanding challenges facing the field of immune engineering from a chemical biology/materials engineering perspectiveNational Institutes of Health (U.S.) (Grants AI111860, CA174795, CA172164, AI091693, and AI095109)United States. Department of Defense (W911NF-13-D-0001 and Awards W911NF-07-D-0004
    corecore