53 research outputs found

    Objective evaluation method using multiple image analyses for panoramic radiography improvement

    Get PDF
    Introduction: In the standardization of panoramic radiography quality, the education and training of beginners on panoramic radiographic imaging are important. We evaluated the relationship between positioning error factors and multiple image analysis results for reproducible panoramic radiography. Material and methods: Using a panoramic radiography system and a dental phantom, reference images were acquired on the Frankfurt plane along the horizontal direction, midsagittal plane along the left-right direction, and for the canine on the forward-backward plane. Images with positioning errors were acquired with 1-5 mm shifts along the forward-backward direction and 2-10 degrees rotations along the horizontal (chin tipped high/low) and vertical (left-right side tilt) directions on the Frankfurt plane. The cross-correlation coefficient and angle difference of the occlusion congruent plane profile between the reference and positioning error images, peak signal-to-noise ratio (PSNR), and deformation vector value by deformable image registration were compared and evaluated. Results: The cross-correlation coefficients of the occlusal plane profiles showed the greatest change in the chin tipped high images and became negatively correlated from 6 degrees image rotation (r = -0.29). The angle difference tended to shift substantially with increasing positioning error, with an angle difference of 8.9 degrees for the 10 degrees chin tipped low image. The PSNR was above 30 dB only for images with a 1-mm backward shift. The positioning error owing to the vertical rotation was the largest for the deformation vector value. Conclusions: Multiple image analyses allow to determine factors contributing to positioning errors in panoramic radiography and may enable error correction. This study based on phantom imaging can support the education of beginners regarding panoramic radiography

    Evaluating the index of panoramic X-ray image quality using K-means clustering method

    Get PDF
    Background A panoramic X-ray image is generally considered optimal when the occlusal plane is slightly arched, presenting with a gentle curve. However, the ideal angle of the occlusal plane has not been determined. This study provides a simple evaluation index for panoramic X-ray image quality, built using various image and cluster analyzes, which can be used as a training tool for radiological technologists and as a reference for image quality improvement. Results A reference panoramic X-ray image was acquired using a phantom with the Frankfurt plane positioned horizontally, centered in the middle, and frontal plane centered on the canine teeth. Other images with positioning errors were acquired with anteroposterior shifts, vertical rotations of the Frankfurt plane, and horizontal left/right rotations. The reference and positioning-error images were evaluated with the cross-correlation coefficients for the occlusal plane profile, left/right angle difference, peak signal-to-noise ratio (PSNR), and deformation vector fields (DVF). The results of the image analyzes were scored for positioning-error images using K-means clustering analysis. Next, we analyzed the correlations between the total score, cross-correlation analysis of the occlusal plane curves, left/right angle difference, PSNR, and DVF. In the scoring, the positioning-error images with the highest quality were the ones with posterior shifts of 1 mm. In the analysis of the correlations between each pair of results, the strongest correlations (r = 0.7–0.9) were between all combinations of PSNR, DVF, and total score. Conclusions The scoring of positioning-error images using K-means clustering analysis is a valid evaluation indicator of correct patient positioning for technologists in training

    Inner Magnetospheric Response to the Interplanetary Magnetic Field By Component:Van Allen Probes and Arase Observations

    Get PDF
    We utilise 17 years of combined Van Allen Probes and Arase data to statistically analyse the response of the inner magnetosphere to the orientation of the IMF By component. Past studies have demonstrated that the IMF By component introduces a similarly oriented By component into the magnetosphere. However, these studies have tended to focus on field lines in the magnetotail only reaching as close to Earth as geosynchronous orbit. By exploiting data from these inner magnetospheric spacecraft, we have been able to investigate the response at radial distances of < 7 RE. When subtracting the background magnetic field values, provided by the T01 and IGRF magnetic field models, we find that the IMF By component does affect the configuration of the magnetic field lines in the inner magnetosphere. This control is observed throughout the inner magnetosphere, across both hemispheres, all radial distances, and all MLT sectors. The ratio of IMF By to observed By residual, also known as the "penetration efficiency", is found to be ~0.33. The IMF Bz component is found to increase, or inhibit, this control depending upon its orientation

    Efficacy of glutathione for the treatment of nonalcoholic fatty liver disease: an open-label, single-arm, multicenter, pilot study

    Get PDF
    Background: Glutathione plays crucial roles in the detoxification and antioxidant systems of cells and has been used to treat acute poisoning and chronic liver diseases by intravenous injection. This is a first study examining the therapeutic effects of oral administration of glutathione in patients with nonalcoholic fatty liver disease (NAFLD). Methods: The study was an open label, single arm, multicenter, pilot trial. Thirty-four NAFLD patients diagnosed using ultrasonography were prospectively evaluated. All patients first underwent intervention to improve their lifestyle habits (diet and exercise) for 3 months, followed by treatment with glutathione (300 mg/day) for 4 months. We evaluated their clinical parameters before and after glutathione treatment. We also quantified liver fat and fibrosis using vibration-controlled transient elastography. The primary outcome of the study was the change in alanine aminotransferase (ALT) levels. Results: Twenty-nine patients finished the protocol. ALT levels significantly decreased following treatment with glutathione for 4 months. In addition, triglycerides, non-esterified fatty acids, and ferritin levels also decreased with glutathione treatment. Following dichotomization of ALT responders based on a median 12.9% decrease from baseline, we found that ALT responders were younger in age and did not have severe diabetes compared with ALT non-responders. The controlled attenuation parameter also decreased in ALT responders. Conclusions: This pilot study demonstrates the potential therapeutic effects of oral administration of glutathione in practical dose for patients with NAFLD. Large-scale clinical trials are needed to verify its efficacy. Trial registration: UMIN000011118 (date of registration: July 4, 2013)

    Active auroral arc powered by accelerated electrons from very high altitudes

    Get PDF
    オーロラ粒子の加速領域が超高高度まで広がっていたことを解明 -オーロラ粒子の加速の定説を覆す発見-. 京都大学プレスリリース. 2021-01-20.Bright, discrete, thin auroral arcs are a typical form of auroras in nightside polar regions. Their light is produced by magnetospheric electrons, accelerated downward to obtain energies of several kilo electron volts by a quasi-static electric field. These electrons collide with and excite thermosphere atoms to higher energy states at altitude of ~ 100 km; relaxation from these states produces the auroral light. The electric potential accelerating the aurora-producing electrons has been reported to lie immediately above the ionosphere, at a few altitudes of thousand kilometres1. However, the highest altitude at which the precipitating electron is accelerated by the parallel potential drop is still unclear. Here, we show that active auroral arcs are powered by electrons accelerated at altitudes reaching greater than 30, 000 km. We employ high-angular resolution electron observations achieved by the Arase satellite in the magnetosphere and optical observations of the aurora from a ground-based all-sky imager. Our observations of electron properties and dynamics resemble those of electron potential acceleration reported from low-altitude satellites except that the acceleration region is much higher than previously assumed. This shows that the dominant auroral acceleration region can extend far above a few thousand kilometres, well within the magnetospheric plasma proper, suggesting formation of the acceleration region by some unknown magnetospheric mechanisms

    Magnetic field and energetic particle flux oscillations and high- frequency waves deep in the inner magnetosphere during substorm dipolarization: ERG observations

    Get PDF
    Using Exploration of energization and Radiation in Geospace (ERG or Arase) spacecraft data, we studied low-frequency magnetic field and energetic particle flux oscillations and high-frequency waves deep in the inner magnetosphere at a radial distance of ~4–5 during substorm dipolarization. The magnetic field oscillated alternately between dipole-like and taillike configuration at a period of 1 min during dipolarization. When the magnetic field was dipole-like, the parallel magnetic component of the Pi2 waves was at trough. Both energetic ion and electron fluxes with a few to tens of kiloelectronvolts enhanced out of phase, indicating that magnetosonic waves were in slow mode. Field-aligned currents also oscillated. These observations are consistent with signatures of ballooning instability. In addition, we found that broadband waves from the Pi1 range to above the electron cyclotron frequency tended to appear intermittently in the central plasma sheet near dipole-like configuration

    Complications Associated With Spine Surgery in Patients Aged 80 Years or Older: Japan Association of Spine Surgeons with Ambition (JASA) Multicenter Study

    Get PDF
    Study Design:Retrospective study of registry data.Objectives:Aging of society and recent advances in surgical techniques and general anesthesia have increased the demand for spinal surgery in elderly patients. Many complications have been described in elderly patients, but a multicenter study of perioperative complications in spinal surgery in patients aged 80 years or older has not been reported. Therefore, the goal of the study was to analyze complications associated with spine surgery in patients aged 80 years or older with cervical, thoracic, or lumbar lesions.Methods:A multicenter study was performed in patients aged 80 years or older who underwent 262 spinal surgeries at 35 facilities. The frequency and severity of complications were examined for perioperative complications, including intraoperative and postoperative complications, and for major postoperative complications that were potentially life threatening, required reoperation in the perioperative period, or left a permanent injury.Results:Perioperative complications occurred in 75 of the 262 surgeries (29%) and 33 were major complications (13%). In multivariate logistic regression, age over 85 years (hazard ratio [HR] = 1.007, P = 0.025) and estimated blood loss ≥500 g (HR = 3.076, P = .004) were significantly associated with perioperative complications, and an operative time ≥180 min (HR = 2.78, P = .007) was significantly associated with major complications.Conclusions:Elderly patients aged 80 years or older with comorbidities are at higher risk for complications. Increased surgical invasion, and particularly a long operative time, can cause serious complications that may be life threatening. Therefore, careful decisions are required with regard to the surgical indication and procedure in elderly patients

    Risk Factors for Delirium After Spine Surgery in Extremely Elderly Patients Aged 80 Years or Older and Review of the Literature: Japan Association of Spine Surgeons with Ambition Multicenter Study

    Get PDF
    Study Design:Retrospective database analysis.Objective:Spine surgeries in elderly patients have increased in recent years due to aging of society and recent advances in surgical techniques, and postoperative complications have become more of a concern. Postoperative delirium is a common complication in elderly patients that impairs recovery and increases morbidity and mortality. The objective of the study was to analyze postoperative delirium associated with spine surgery in patients aged 80 years or older with cervical, thoracic, and lumbar lesions.Methods:A retrospective multicenter study was performed in 262 patients 80 years of age or older who underwent spine surgeries at 35 facilities. Postoperative complications, incidence of postoperative delirium, and hazard ratios of patient-specific and surgical risk factors were examined.Results:Postoperative complications occurred in 59 of the 262 spine surgeries (23%). Postoperative delirium was the most frequent complication, occurring in 15 of 262 patients (5.7%), and was significantly associated with hypertension, cerebrovascular disease, cervical lesion surgery, and greater estimated blood loss (P < .05). In multivariate logistic regression using perioperative factors, cervical lesion surgery (odds ratio = 4.27, P < .05) and estimated blood loss ≥300 mL (odds ratio = 4.52, P < .05) were significantly associated with postoperative delirium.Conclusions:Cervical lesion surgery and greater blood loss were perioperative risk factors for delirium in extremely elderly patients after spine surgery. Hypertension and cerebrovascular disease were significant risk factors for postoperative delirium, and careful management is required for patients with such risk factors

    Development of a Bridge Inspection Robot Capable of Traveling on Splicing Parts

    No full text
    Several infrastructures, such as bridges and tunnels, require periodic inspection and repair to prevent collapse. There is a strong demand for practical bridge inspection robots to reduce the cost and time associated with the inspection of bridges by an inspector. Bridge inspection robots are expected to pass through obstacles such as bolted splice part and right-angled routes. The aim of this study involved developing a bridge inspection robot that can travel on a right-angle path as well as splicing parts. A two-wheel-drive robot was developed and equipped with two rimless wheels as driving wheels. A neodymium magnet was provided at the tip of each spoke. Non-driving wheels were attached at the rear as a rotatable caster. The robot can turn on the spot to avoid the bolt on the splicing part. Experiments were conducted to check the performance of the robot. The results confirmed that the robot passed through the internal right-angle paths in a laboratory and in an actual environment that corresponds to a box girder of a bridge. It is extremely difficult to manually control a robot on the splicing part. Therefore, a camera and an LED (light emitting diode) were attached to autonomously control the robot. The results indicate that the newly developed robot could run through the splicing part without hitting the nuts
    corecore