8 research outputs found
Position resolution and particle identification with the ATLAS EM calorimeter
In the years between 2000 and 2002 several pre-series and series modules of
the ATLAS EM barrel and end-cap calorimeter were exposed to electron, photon
and pion beams. The performance of the calorimeter with respect to its finely
segmented first sampling has been studied. The polar angle resolution has been
found to be in the range 50-60 mrad/sqrt(E (GeV)). The neutral pion rejection
has been measured to be about 3.5 for 90% photon selection efficiency at pT=50
GeV/c. Electron-pion separation studies have indicated that a pion fake rate of
(0.07-0.5)% can be achieved while maintaining 90% electron identification
efficiency for energies up to 40 GeV.Comment: 32 pages, 22 figures, to be published in NIM
Response uniformity of the ATLAS liquid argon electromagnetic calorimeter
The construction of the ATLAS electromagnetic liquid argon calorimeter modules is completed and all the modules are assembled and inserted in the cryostats. During the production period four barrel and three endcap modules were exposed to test beams in order to assess their performance, ascertain the production quality and reproducibility, and to scrutinize the complete energy reconstruction chain from the readout and calibration electronics to the signal and energy reconstruction. It was also possible to check the full Monte Carlo simulation of the calorimeter. The analysis of the uniformity, resolution and extraction of constant term is presented. Typical non-uniformities of 5 ‰ and typical global constant terms of 6 ‰ are measured for the barrel and endcap modules. © 2007 Elsevier B.V. All rights reserved
Response uniformity of the ATLAS liquid argon electromagnetic calorimeter
Accepted by NIM AThe construction of the ATLAS electromagnetic liquid argon calorimeter modules is completed and all the modules are assembled and inserted in the cryostats. During the production period four barrel and three endcap modules were exposed to test beams in order to assess their performance, ascertain the production quality and reproducibility, and to scrutinize the complete energy reconstruction chain from the readout and calibration electronics to the signal and energy reconstruction. It was also possible to check the full Monte Carlo simulation of the calorimeter. The analysis of the uniformity, resolution and extraction of constant term is presented. Typical non-uniformities of 0.5% and typical global constant terms of 0.6% are measured for the barrel and end-cap modules
Study of the response of ATLAS electromagnetic liquid argon calorimeters to muons
The response of the ATLAS electromagnetic calorimeter 1 to muons has been studied in this paper. Results on signal over noise ratio, assessment of the detector response uniformity, and position resolution are presented. The possibility to study fine de4 tails of the structure of the detector through its response to muons is illustrated on a specific example. Finally, the performance obtained on muons in test-beam is used to estimate the detector uniformity and time alignment precision that will be reachable after the commissioning of the ATLAS detector with cosmic rays