20 research outputs found

    Development of a PCR /RLB Test for meat source authentication in processed meat and meat products

    Get PDF
    Concern over food authenticity has increased as a result of an increase in the consumption of processed foods containing meat or animal products. This raises a number of issues where the presence of pork in such foods is considered unacceptable in most Muslim and Jewish communities around the world. It also applied to the prohibition of beef consumption among Hindus. In order to ensure the absence of unwished meat products or mixing of meats from different sources in processed foods, a specific and sensitive test is essential. For this purpose we developed a molecular test based on DNA amplification by polymerase chain reaction (PCR) of the cytochrome b gene followed by reverse line blot analysis (RLB). Using this method many samples may be treated simultaneously and meat origins can easily be detected from processed foods or foods containing mixed meat sources; also, added pork components such as fat may be identified by this methodology. The PCR/RLB method is considered to be a sensitive and specific technique; it can detect one nucleotide change within the PCR-amplified DNA segment.This study was supported by the Arab Science and Technology Foundation, grant number BT072239

    Development of a PCR/RLB Test for Meat Source Authentication in Processed Meat and Meat Products

    No full text
    Concern over food authenticity has increased as a result of an increase in the consumption of processed foods containing meat or animal products. This raises a number of issues where the presence of pork in such foods is considered unacceptable in most Muslim and Jewish communities around the world. It also applied to the prohibition of beef consumption among Hindus. In order to ensure the absence of unwished meat products or mixing of meats from different sources in processed foods, a specific and sensitive test is essential. For this purpose we developed a molecular test based on DNA amplification by polymerase chain reaction (PCR) of the cytochrome b gene followed by reverse line blot analysis (RLB). Using this method many samples may be treated simultaneously and meat origins can easily be detected from processed foods or foods containing mixed meat sources; also, added pork components such as fat may be identified by this methodology. The PCR/RLB method is considered to be a sensitive and specific technique; it can detect one nucleotide change within the PCR-amplified DNA segment

    Deep-dished highly congruent tibial insert in CR-TKA does not prevent patellar tendon angle increase and patellar anterior translation

    No full text
    PURPOSE: Starting from the hypothesis that a deep-dished highly congruent tibial insert in cruciate-retaining total knee arthroplasty would prevent the increase in patellar tendon angle and anterior patellar translation by reducing the paradoxical anterior femoral translation, the main purpose of the present study was to investigate the effect of this prosthesis design, and secondary to assess the clinical outcomes at 6-month follow-up. METHODS: Twenty patients treated with cruciate-retaining total knee arthroplasty with navigation technique were enrolled and prospectively followed up at 6 months. The median value of age was 71 years (57-83). Before and after surgery, the following parameters were calculated: patellar tendon angle, anterior-posterior and medio-lateral patellar translation, patellar height and range of motion. All patients were assessed with the SF-36 Physical Functioning and the Knee injury and Osteoarthritis Outcome Score ADL scores. RESULTS: Patellar tendon angle and anterior patellar translation significantly increased in post-operative conditions (p < 0.0001); a statistically significant medial patellar translation was found (p < 0.0001), while patellar height did not show any difference between pre- and post-operative conditions (n.s). A significant correlation was found between patellar tendon angle and anterior patellar translation and the clinical scores (p < 0.0417). There was a significant post-operative decrease (p < 0.0033) in the range of motion. CONCLUSIONS: The present study failed to demonstrate that deep-dished highly congruent tibial insert prevents the anterior translation of the patella in cruciate-retaining total knee arthroplasty, thus causing inferior clinical scores. It provided useful information about the biomechanical role of the patella in total knee arthroplasty, allowing to choose the most appropriate surgical approach. LEVEL OF EVIDENCE: Case series, Level IV

    Three different cruciate-sacrificing TKA designs: minor intraoperative kinematic differences and negligible clinical differences

    No full text
    PURPOSE: The goal of this study was to compare three types of mobile-bearing posterior cruciate ligament (PCL)-sacrificing TKA. The hypothesis was that the three designs provide differences in flexion stability and femoral rollback and improved clinical score at 2-year follow-up. METHODS: Three groups of patients, divided according to implant design, were analysed retrospectively. All operations were guided by a non-image-based navigation system that recorded relative femoral and tibial positions in native and implanted knees during: passive range of motion and anterior drawer test at 90° flexion. WOMAC, KSS and SF36 scores were collected pre-operatively and at 2-year follow-up. RESULTS: There are no differences in kinematic or clinical performance of the three implants, except for the antero-posterior translation during stress test in flexion: only Cohort B had comparable pre- and post-operative laxity test values (p < 0.001). All three TKA designs allowed to maintain pre-operative tibial rotation pattern through all range of knee flexion. All clinical scores of the three patient cohorts were significantly improved post-operatively compared to the pre-operative values (p < 0.001). Moreover, we found no differences among post-operative results of the three designs. CONCLUSION: Despite design variations, mobile-bearing PCL-sacrificing TKA reproduces femoral rollback and screw-home with little or no difference in clinical or functional scores at a follow-up of 2 years. LEVEL OF EVIDENCE: III

    Roentgen stereophotogrammetric analysis: an effective tool to predict implant survival after an all-poly unicompartmental knee arthroplasty\u2014a 10\ua0year follow-up study

    No full text
    The main purpose of the present study was to determine long-term implant fixation of 15 unicompartmental knee arthroplasty (UKAs) with an all-poly tibial component using Roentgen stereophotogrammetric analysis (RSA) at a mean 10-year follow-up. The secondary purpose was to investigate whether the progressive loss of implant's fixation correlates with a reduction in Knee society score (KSS). METHODS: Fifteen non-consecutive patients with primary knee osteoarthritis received a UKA with an all-poly tibial component were assessed using KSS scores pre-operatively and post-operatively and RSA on day 2 after surgery, then at 3, 6, and 12 months and yearly thereafter. The mean last follow-up was 10 years. RESULTS: An increase in maximum total point motion (MTPM) values from 6 months to 1 year post-operatively was found respect to post-operative reference. Implants' displacement values were always 0.2 mm in revised UKAs. A linear and negative correlation with statistical significance was found between MTPM and both clinical and functional KSS scores (p < 0.001). CONCLUSION: Also in a long-term follow-up evaluation, RSA is an effective tool to predict functional results after an all-poly UKA providing also a relevant predictive value at 1 year follow-up, and this can be very useful for both patients and surgeons

    Good survivorship of all-polyethylene tibial component UKA at long-term follow-up

    No full text
    Purposes: To determine the long-term survival rate of an all-polyethylene tibial unicompartmental knee arthroplasty (UKA) in a large series of consecutive patients and to investigate the possible factors that could influence the outcome. Methods: A retrospective evaluation of 273 patients at 6\u201313\ua0years of follow-up was performed. Clinical evaluation was based on KSS and WOMAC scores. Subjective evaluation was based on a visual analogue scale for pain self-assessment. Radiographic evaluation was performed to assess femoral-tibial angle (FTA), posterior tibial slope (PTS) and tibial plateau angle (TPA). A Kaplan\u2013Meier survival analysis was performed assuming revision for any reason as primary endpoint. Results: The 10-year implant survivorship was 87.6\ua0%. Twenty-five revisions (9.2\ua0%) were performed, and aseptic loosening of the tibial component was the most common failure mode (11 cases, 4\ua0%). The comparison of survival rate according to age at surgery did not show significant difference. Age at surgery, FTA, TPA and PTS were not related to higher risk of revision. No correlations were found between BMI, age at surgery and clinical scores. Finally, no statistical differences of radiographic measurements were found between revisions and non-revisions. Conclusions: The present study has demonstrated on a large series of patients that UKA with an all-polyethylene tibial component, with an accurate technique and a proper patient selection, can provide a satisfactory clinical and functional outcome and a good overall survivorship of the implant at long-term follow-up. These advantages could be achieved at a lower cost. Level of evidence: Retrospective Therapeutic Study, Level IV

    WWOX somatic ablation in skeletal muscles alters glucose metabolism

    No full text
    Objective: WWOX, a well-established tumor suppressor, is frequently lost in cancer and plays important roles in DNA damage response and cellular metabolism. Methods: We re-analyzed several genome-wide association studies (GWAS) using the Type 2 Diabetes Knowledge Portal website to uncover WWOX's association with metabolic syndrome (MetS). Using several engineered mouse models, we studied the effect of somatic WWOX loss on glucose homeostasis. Results: Several WWOX variants were found to be strongly associated with MetS disorders. In mouse models, somatic ablation of Wwox in skeletal muscle (WwoxΔSKM) results in weight gain, glucose intolerance, and insulin resistance. Furthermore, WwoxΔSKM mice display reduced amounts of slow-twitch fibers, decreased mitochondrial quantity and activity, and lower glucose oxidation levels. Mechanistically, we found that WWOX physically interacts with the cellular energy sensor AMP-activated protein kinase (AMPK) and that its loss is associated with impaired activation of AMPK, and with significant accumulation of the hypoxia inducible factor 1 alpha (HIF1α) in SKM. Conclusions: Our studies uncover an unforeseen role of the tumor suppressor WWOX in whole-body glucose homeostasis and highlight the intimate relationship between cancer progression and metabolic disorders, particularly obesity and type-2 diabetes. Subject areas: Genetics, Metabolic Syndrome, Diabetes. Keywords: Metabolic syndrome, Tumor suppressor, T2D, WWOX, AMP

    Unicompartmental knee arthroplasty in patients over 75\ua0years: a definitive solution?

    No full text
    The purpose of this study was to perform a mid-long-term clinical and radiographic evaluation of the results obtained in patients older than 75\ua0years treated with minimally invasive unicompartmental knee arthroplasty (UKA). The hypothesis was that UKA is a viable solution for the definitive treatment of localized disease in this age group, with good results and a low failure rate
    corecore