9 research outputs found

    Combined miRNA and SERS urine liquid biopsy for the point-of-care diagnosis and molecular stratification of bladder cancer

    Get PDF
    Background: Bladder cancer (BC) has the highest per-patient cost of all cancer types. Hence, we aim to develop a non-invasive, point-of-care tool for the diagnostic and molecular stratification of patients with BC based on combined microRNAs (miRNAs) and surface-enhanced Raman spectroscopy (SERS) profiling of urine. Methods: Next-generation sequencing of the whole miRNome and SERS profiling were performed on urine samples collected from 15 patients with BC and 16 control subjects (CTRLs). A retrospective cohort (BC = 66 and CTRL = 50) and RT-qPCR were used to confirm the selected differently expressed miRNAs. Diagnostic accuracy was assessed using machine learning algorithms (logistic regression, naive Bayes, and random forest), which were trained to discriminate between BC and CTRL, using as input either miRNAs, SERS, or both. The molecular stratification of BC based on miRNA and SERS profiling was performed to discriminate between high-grade and low-grade tumors and between luminal and basal types. Results: Combining SERS data with three differentially expressed miRNAs (miR-34a-5p, miR-205-3p, miR-210-3p) yielded an Area Under the Curve (AUC) of 0.92 +/- 0.06 in discriminating between BC and CTRL, an accuracy which was superior either to miRNAs (AUC = 0.84 +/- 0.03) or SERS data (AUC = 0.84 +/- 0.05) individually. When evaluating the classification accuracy for luminal and basal BC, the combination of miRNAs and SERS profiling averaged an AUC of 0.95 +/- 0.03 across the three machine learning algorithms, again better than miRNA (AUC = 0.89 +/- 0.04) or SERS (AUC = 0.92 +/- 0.05) individually, although SERS alone performed better in terms of classification accuracy. Conclusion: miRNA profiling synergizes with SERS profiling for point-of-care diagnostic and molecular stratification of BC. By combining the two liquid biopsy methods, a clinically relevant tool that can aid BC patients is envisaged

    Abstracts from the Food Allergy and Anaphylaxis Meeting 2016

    Get PDF

    An Adaptive Learning System for Stepwise Automatisation of Multiplication Facts in Primary Education

    No full text
    We demonstrate an application for learning multiplication problems with an adaptive algorithm that is based on a computational cognitive model of the learner's memory. The application helps learners automatise multiplications through repeated practice over three levels of difficulty. In a naturalistic setting involving more than 500 primary school students (ages 6-10) who together recorded over 200,000 responses, we observed that performance improved as learners using the application progressed through the levels. A model-based analysis of performance revealed that learners' estimated speed of forgetting decreased from the second to the third level. This is consistent with a shift towards stronger declarative knowledge and/or more efficient computation procedures. The model also identified consistent differences in the difficulty of individual multiplication facts that persisted across levels. This study demonstrates the feasibility of using an adaptive fact learning application to help young learners automatise multiplication, an essential mathematical skill

    The role of adatoms in chloride-activated colloidal silver nanoparticles for surface-enhanced Raman scattering enhancement

    No full text
    Chloride-capped silver nanoparticles (Cl-AgNPs) allow for high-intensity surface-enhanced Raman scattering (SERS) spectra of cationic molecules to be obtained (even at nanomolar concentration) and may also play a key role in understanding some fundamental principles behind SERS. In this study, we describe a fast (<10 min) and simple protocol for obtaining highly SERS-active colloidal silver nanoparticles (AgNPs) with a mean diameter of 36 nm by photoconversion from AgCl precursor microparticles in the absence of any organic reducing or capping agent. The resulting AgNPs are already SERS-activated by the Cl− ions chemisorbed onto the metal surface where the chloride concentration in the colloidal solution is 10−2 M. Consequently, the enhanced SERS spectra of cationic dyes (e.g., crystal violet or 9-aminoacridine) demonstrate the advantages of Cl-AgNPs compared to the as-synthesized AgNPs obtained by standard Ag+ reduction with hydroxylamine (hya-AgNPS) or citrate (cit-AgNPs). The results of SERS experiments on anionic and cationic test molecules comparing Cl-AgNPs, hya-AgNPs and cit-AgNPs colloids activated with different amounts of Cl− and/or cations such as Ag+, Mg2+ or Ca2+ can be explained within the understanding of the adatom model – the chemisorption of cationic analytes onto the metal surface is mediated by the Cl− ions, whereas ions like Ag+, Mg2+ or Ca2+ mediate the electronic coupling of anionic species to the silver metal surface. Moreover, the SERS effect is switched on only after the electronic coupling of the adsorbate to the silver surface at SERS-active sites. The experiments presented in this study highlight the SERS-activating role played by ions such as Cl−, Ag+, Mg2+ or Ca2+, which is a process that seems to prevail over the Raman enhancement due to nanoparticle aggregation

    Correlation between Volumes Determined by Echocardiography and Cardiac MRI in Controls and Atrial Fibrillation Patients

    No full text
    Aims: We aimed to compare cardiac volumes measured with echocardiography (echo) and cardiac magnetic resonance imaging (MRI) in a mixed cohort of healthy controls (controls) and patients with atrial fibrillation (AF). Materials and methods: In total, 123 subjects were included in our study; 99 full datasets were analyzed. All the participants underwent clinical evaluation, EKG, echo, and cardiac MRI acquisition. Participants with full clinical data were grouped into 63 AF patients and 36 controls for calculation of left atrial volume (LA Vol) and 51 AF patients and 30 controls for calculation of left ventricular end-diastolic volume (LV EDV), end-systolic volume (ESV), and LV ejection fraction (LV EF). Results: No significant differences in LA Vol were observed (p &gt; 0.05) when measured by either echo or MRI. However, echo provided significantly lower values for left ventricular volume (p &lt; 0.0001). The echo LA Vol of all the subjects correlated well with that measured by MRI (Spearmen correlation coefficient r = 0.83, p &lt; 0.0001). When comparing the two methods, significant positive correlations of EDV (all subjects: r = 0.55; Controls: r = 0.71; and AF patients: r = 0.51) and ESV (all subjects: r = 0.62; Controls: r = 0.47; and AF patients: r = 0.66) were found, with a negative bias for values determined using echo. For a subgroup of participants with ventricular volumes smaller than 49.50 mL, this bias was missing, thus in this case echocardiography could be used as an alternative for MRI. Conclusion: Good correlation and reduced bias were observed for LA Vol and EF determined by echo as compared to cardiac MRI in a mixed cohort of patients with AF and healthy volunteers. For the determination of volume values below 49.50 mL, an excellent correlation was observed between values obtained using echo and MRI, with comparatively reduced bias for the volumes determined by echo. Therefore, in certain cases, echocardiography could be used as a less expensive, less time-consuming, and contraindication free alternative to MRI for cardiac volume determination

    SERS Liquid Biopsy Profiling of Serum for the Diagnosis of Kidney Cancer

    No full text
    Renal cancer (RC) represents 3% of all cancers, with a 2% annual increase in incidence worldwide, opening the discussion about the need for screening. However, no established screening tool currently exists for RC. To tackle this issue, we assessed surface-enhanced Raman scattering (SERS) profiling of serum as a liquid biopsy strategy to detect renal cell carcinoma (RCC), the most prevalent histologic subtype of RC. Thus, serum samples were collected from 23 patients with RCC and 27 controls (CTRL) presenting with a benign urological pathology such as lithiasis or benign prostatic hypertrophy. SERS profiling of deproteinized serum yielded SERS band spectra attributed mainly to purine metabolites, which exhibited higher intensities in the RCC group, and Raman bands of carotenoids, which exhibited lower intensities in the RCC group. Principal component analysis (PCA) of the SERS spectra showed a tendency for the unsupervised clustering of the two groups. Next, three machine learning algorithms (random forest, kNN, naïve Bayes) were implemented as supervised classification algorithms for achieving discrimination between the RCC and CTRL groups, yielding an AUC of 0.78 for random forest, 0.78 for kNN, and 0.76 for naïve Bayes (average AUC 0.77 ± 0.01). The present study highlights the potential of SERS liquid biopsy as a diagnostic and screening strategy for RCC. Further studies involving large cohorts and other urologic malignancies as controls are needed to validate the proposed SERS approach

    SERS-Based Evaluation of the DNA Methylation Pattern Associated With Progression in Clonal Leukemogenesis of Down Syndrome

    No full text
    Here we show that surface-enhanced Raman scattering (SERS) analysis captures the relative hypomethylation of DNA from patients with acute leukemia associated with Down syndrome (AL-DS) compared with patients diagnosed with transient leukemia associated with Down syndrome (TL-DS), an information inferred from the area under the SERS band at 1005 c
    corecore