34 research outputs found

    Applying Energy Absorption Interferometry to THz direct detectors using photomixers

    Full text link
    Detector requirements for far infrared astronomy generally result in devices which exhibit a few-moded response to incident radiation. The sensitivity and spatial form of the individual modes to which such a detector is sensitive can be determined with knowledge of the complex valued cross-spectral density of the system, which we label the detector response function (DRF). A matrix representing the discretized cross-spectral density can be measured from the complex amplitudes of interference fringes generated by two identical sources as they are independently scanned through the field of view. We provide experimental verification of this technique using monochromatic THz beams generated by photomixers in which the relative phase is varied with fiber stretchers. We use this system to characterize the modal response of a single pixel from an array of microwave kinetic inductance detectors (MKIDs).Comment: in IEEE Transactions on Terahertz Science and Technology. 202

    A novel design for a cryogenic Fabry-Pérot interferometer

    Get PDF
    The sensitivity of state-of-the-art superconducting far-infrared detectors is such that astronomical observations at these wavelengths are limited by photon noise from the astronomical source unless a method of restricting the spectral bandpass is employed. One such method is to use a high resolution Fabry-Pérot interferometer (FPI) in conjunction with a lower resolution, post dispersing system, such as a grating spectrometer. The resonant wavelength of an FPI is typically tuned by changing the spacing or medium between the parallel reflecting plates of the etalon. We present a novel design in which the wavelength is tuned by scanning the angle of incidence, which simplifies the cryo-mechanical design, actuation and metrology. The effects on the spectral response as a function of incident angle have been simulated and shown to be manageable

    A Cryogenic test facility

    Get PDF
    The next generation, space-borne instruments for far infrared spectroscopy will utilize large diameter, cryogenically cooled telescopes in order to achieve unprecedented sensitivities. Low background, ground-based cryogenic facilities are required for the cryogenic testing of materials, components and subsystems. The Test Facility Cryostat (TFC) at the University of Lethbridge is a large volume, closed cycle, 4K cryogenic facility, developed for this purpose. This thesis discusses the design and performance of the facility and associated external instrumentation. An apparatus for measuring the thermal properties of materials is presented, and measurements of the thermal expansion and conductivity of carbon fibre reinforced polymers (CFRPs) at cryogenic temperatures are reported. Finally, I discuss the progress towards the design and fabrication of a demonstrator cryogenic, far infrared Fourier transform spectrometer

    An angle-scanned cryogenic Fabry-Pérot interferometer for far-infrared astronomy

    Get PDF
    The sensitivity of state-of-the-art superconducting far-infrared detectors used in conjunction with cryogenically cooled space telescopes and instrumentation is such that spectroscopic observations are generally limited by photon noise from the astronomical source or by galactic foreground or zodiacal emission within the field-of-view. Therefore, an instrument design that restricts the spectral bandpass viewed by the detector must be employed. One method of achieving background limited, high resolution spectroscopy is to combine a high resolution component such as a Fabry–Pérot interferometer (FPI) with a lower resolution, post-dispersing system, such as a grating spectrometer, the latter serving to restrict the spectral bandpass. The resonant wavelength of an FPI is most often tuned by changing the spacing or medium between the parallel reflecting plates of the etalon. In this paper, we present a novel design for an FPI in which the wavelength is tuned by scanning the angle of incidence on a high refractive index etalon. This concept simplifies the cryomechanical design, actuation, and metrology. The first results from the realized instrument are presented and compared with theory. The effects on the spectral response as a function of the incident angle have been simulated and shown to agree well with the observation

    Performance of a cryogenic test facility for 4 K interferometer delay line investigations

    Get PDF
    The next generation of space-borne instruments for far infrared astronomical spectroscopy will utilize large diameter, cryogenically cooled telescopes in order to achieve unprecedented sensitivities. Low background, ground-based cryogenic facilities are required for the cryogenic testing of materials, components and subsystems. The University of Lethbridge Test Facility Cryostat (TFC) is a large volume, closed cycle, 4 K cryogenic facility, developed for this purpose. This paper discusses the design and performance of the facility and associated metrology instrumentation, both internal and external to the TFC. Additionally, an apparatus for measuring the thermal and mechanical properties of carbon-fiber-reinforced polymers is presented

    Development and validation of a cryogenic far-infrared diffraction grating spectrometer used to post-disperse the output from a Fourier transform spectrometer

    Get PDF
    Recent advances in far-infrared detector technology have led to increases in raw sensitivity of more than an order of magnitude over previous state-of-the-art detectors. With such sensitivity, photon noise becomes the dominant noise component, even when using cryogenically cooled optics, unless a method of restricting the spectral bandpass is employed. The leading instrument concept features reflecting diffraction gratings, which post-disperse the light that has been modulated by a polarizing Fourier transform spectrometer (FTS) onto a detector array, thereby reducing the photon noise on each detector. This paper discusses the development of a cryogenic (4 K) diffraction grating spectrometer that operates over the wavelength range of 285 to 500 μm and was used to post-disperse the output from a room-temperature polarizing FTS. Measurements of the grating spectral response and diffraction efficiency are presented as a function of both wavelength and polarization to characterize the instrumental performance

    First light results from a novel cryogenic Fabry-Pérot interferometer

    Get PDF
    The sensitivity of state-of-the-art superconducting far-infrared detectors is such that astronomical observations at these wavelengths are limited by photon noise from the astronomical source unless a method of restricting the spectral bandpass is employed. One such method is to use a high resolution Fabry-Perot interferometer (FPI) in conjunction with a lower resolution, post-dispersing system, such as a grating spectrometer. The resonant wavelength of an FPI is typically tuned by changing the spacing or medium between the parallel reflecting plates of the etalon. We previously reported on a novel design in which the wavelength is tuned by scanning the angle of incidence, which simplifies the cryo-mechanical design, actuation and metrology. Here we present first light results from the realized instrument

    In-orbit performance of the Herschel/SPIRE imaging Fourier transform spectrometer: lessons learned

    Get PDF
    The Spectral and Photometric Imaging Receiver (SPIRE) is one of three scientific instruments on board the European Space Agency's Herschel Space Observatory which ended its operational phase on 29 April 2013. The low to medium resolution spectroscopic capability of SPIRE is provided by an imaging Fourier transform spectrometer (iFTS) of the Mach-Zehnder configuration. With their high throughput, broad spectral coverage, and variable resolution, coupled with their well-defined instrumental line shape and intrinsic wavelength and intensity calibration, iFTS are becoming increasingly common in far-infrared space astronomy missions. The performance of the SPIRE imaging spectrometer will be reviewed and example results presented. The lessons learned from the measured performance of the spectrometer as they apply to future missions will be discussed

    3 years of liraglutide versus placebo for type 2 diabetes risk reduction and weight management in individuals with prediabetes: a randomised, double-blind trial

    Get PDF
    Background: Liraglutide 3·0 mg was shown to reduce bodyweight and improve glucose metabolism after the 56-week period of this trial, one of four trials in the SCALE programme. In the 3-year assessment of the SCALE Obesity and Prediabetes trial we aimed to evaluate the proportion of individuals with prediabetes who were diagnosed with type 2 diabetes. Methods: In this randomised, double-blind, placebo-controlled trial, adults with prediabetes and a body-mass index of at least 30 kg/m2, or at least 27 kg/m2 with comorbidities, were randomised 2:1, using a telephone or web-based system, to once-daily subcutaneous liraglutide 3·0 mg or matched placebo, as an adjunct to a reduced-calorie diet and increased physical activity. Time to diabetes onset by 160 weeks was the primary outcome, evaluated in all randomised treated individuals with at least one post-baseline assessment. The trial was conducted at 191 clinical research sites in 27 countries and is registered with ClinicalTrials.gov, number NCT01272219. Findings: The study ran between June 1, 2011, and March 2, 2015. We randomly assigned 2254 patients to receive liraglutide (n=1505) or placebo (n=749). 1128 (50%) participants completed the study up to week 160, after withdrawal of 714 (47%) participants in the liraglutide group and 412 (55%) participants in the placebo group. By week 160, 26 (2%) of 1472 individuals in the liraglutide group versus 46 (6%) of 738 in the placebo group were diagnosed with diabetes while on treatment. The mean time from randomisation to diagnosis was 99 (SD 47) weeks for the 26 individuals in the liraglutide group versus 87 (47) weeks for the 46 individuals in the placebo group. Taking the different diagnosis frequencies between the treatment groups into account, the time to onset of diabetes over 160 weeks among all randomised individuals was 2·7 times longer with liraglutide than with placebo (95% CI 1·9 to 3·9, p<0·0001), corresponding with a hazard ratio of 0·21 (95% CI 0·13–0·34). Liraglutide induced greater weight loss than placebo at week 160 (–6·1 [SD 7·3] vs −1·9% [6·3]; estimated treatment difference −4·3%, 95% CI −4·9 to −3·7, p<0·0001). Serious adverse events were reported by 227 (15%) of 1501 randomised treated individuals in the liraglutide group versus 96 (13%) of 747 individuals in the placebo group. Interpretation: In this trial, we provide results for 3 years of treatment, with the limitation that withdrawn individuals were not followed up after discontinuation. Liraglutide 3·0 mg might provide health benefits in terms of reduced risk of diabetes in individuals with obesity and prediabetes. Funding: Novo Nordisk, Denmark

    Applying Energy Absorption Interferometry to THz Direct Detectors Using Photomixers

    Get PDF
    Detector requirements for far infrared astronomy generally result in devices that exhibit a few-moded response to incident radiation. The sensitivity and spatial form of the individual modes to which such a detector is sensitive can be determined with knowledge of the complex-valued cross-spectral density of the system, which we label the detector response function. A matrix representing the discretized cross-spectral density can be measured from the complex amplitudes of interference fringes generated by two identical sources as they are independently scanned through the field of view. We provide experimental verification of this technique using monochromatic THz beams generated by photomixers in which the relative phase is varied with fiber stretchers. We use this system to characterize the modal response of a single pixel from an array of microwave kinetic inductance detectors.</p
    corecore