199 research outputs found

    Patterns of burns and scalds in Mongolian children: a hospital-based prospective study

    Get PDF
    ObjectiveTo describe the circumstances of burn injury occurrence among Mongolian children and the products involved.MethodsStudy participants were children aged 15 years and younger who were admitted to the Burn Unit of the National Trauma Orthopedic Research Center from August 2015 to July 2016. We collected data on participant demographics and the aetiology and clinical features of their burn injuries, and we analysed the data based on the NOMESCO Classification model.FindingsOf 906 children, 83% were aged 0–3 years, 66% were injured around the cooking area in the traditional tent‐like dwelling called a ger or a detached house where no specified kitchen exists, and 28% were injured in a kitchen. Burn injuries resulted mostly from exposure to overflowing hot liquids (93%). Electric pots and electric kettles were the products most frequently involved in causing burn injuries (41% and 14%, respectively). Of 601 major burn injuries, 52% were due to electric pots. Moreover, burn injuries inflicted by electric pots were most likely to be major burn injuries (83%). Children typically fell into electric pots, while electric kettles were often pulled down by children.ConclusionBurn injuries among Mongolian children mainly occurred in cooking area of a ger involving electric pots. The current practice of cooking on the floor should be reconsidered for child burn prevention

    Plate : persistent memory management for nonvolatile main memory

    Get PDF
    Over the past few years, nonvolatile memory has actively been researched and developed. Therefore, studying operating system (OS) designs predicated on the main memory in the form of a nonvolatile memory and studying methods to manage persistent data in a virtual memory are crucial to encourage the widespread use of nonvolatile memory in the future. However, the main memory in most computers today is volatile, and replacing highcapacity main memory with nonvolatile memory is extremely cost-prohibitive. This paper proposes an OS structure for nonvolatile main memory. The proposed OS structure consists of three functions to study and develop OSs for nonvolatile main memory computers. First, a structure, which is called plate, is proposed whereby persistent data are managed assuming that nonvolatile main memory is present in a computer. Second, we propose a persistent-data mechanism to make a volatile memory function as nonvolatile main memory, which serves as a basis for the development of OSs for computers with nonvolatile main memory. Third, we propose a continuous operation control using the persistent-data mechanism and plates. This paper describes the design and implementation of the OS structure based on the three functions on The ENduring operating system for Distributed EnviRonment and describes the evaluation results of the proposed functions

    Efficacy of tumor-targeting Salmonella typhimurium A1-R in combination with anti-angiogenesis therapy on a pancreatic cancer patient-derived orthotopic xenograft (PDOX) and cell line mouse models.

    Get PDF
    The aim of the present study was to examine the efficacy of tumor-targeting Salmonella typhimurium A1-R treatment following anti-vascular endothelial growth factor (VEGF) therapy on VEGF-positive human pancreatic cancer. A pancreatic cancer patient-derived orthotopic xenograft (PDOX) that was VEGF-positive and an orthotopic VEGF-positive human pancreatic cancer cell line (MiaPaCa-2-GFP) as well as a VEGF-negative cell line (Panc-1) were tested. Nude mice with these tumors were treated with gemcitabine (GEM), bevacizumab (BEV), and S. typhimurium A1-R. BEV/GEM followed by S. typhimurium A1-R significantly reduced tumor weight compared to BEV/GEM treatment alone in the PDOX and MiaPaCa-2 models. Neither treatment was as effective in the VEGF-negative model as in the VEGF-positive models. These results demonstrate that S. typhimurium A1-R following anti-angiogenic therapy is effective on pancreatic cancer including the PDOX model, suggesting its clinical potential

    The tumor-educated-macrophage increase of malignancy of human pancreatic cancer is prevented by zoledronic acid.

    Get PDF
    We previously defined macrophages harvested from the peritoneal cavity of nude mice with subcutaneous human pancreatic tumors as "tumor-educated-macrophages" (Edu) and macrophages harvested from mice without tumors as "naïve-macrophages" (Naïve), and demonstrated that Edu-macrophages promoted tumor growth and metastasis. In this study, Edu- and Naïve-macrophages were compared for their ability to enhance pancreatic cancer malignancy at the cellular level in vitro and in vivo. The inhibitory efficacy of Zoledronic acid (ZA) on Edu-macrophage-enhanced metastasis was also determined. XPA1 human pancreatic cancer cells in Gelfoam co-cultured with Edu-macrophages proliferated to a greater extent compared to XPA1 cells cultured with Naïve-macrophages (P = 0.014). XPA1 cells exposed to conditioned medium harvested from Edu culture significantly increased proliferation (P = 0.016) and had more migration stimulation capability (P<0.001) compared to cultured cancer cells treated with the conditioned medium from Naïve. The mitotic index of the XPA1 cells, expressing GFP in the nucleus and RFP in the cytoplasm, significantly increased in vivo in the presence of Edu- compared to Naïve-macrophages (P = 0.001). Zoledronic acid (ZA) killed both Edu and Naïve in vitro. Edu promoted tumor growth and metastasis in an orthotopic mouse model of the XPA1 human pancreatic cancer cell line. ZA reduced primary tumor growth (P = 0.006) and prevented metastasis (P = 0.025) promoted by Edu-macrophages. These results indicate that ZA inhibits enhanced primary tumor growth and metastasis of human pancreatic cancer induced by Edu-macrophages

    Establishment of a patient-derived orthotopic Xenograft (PDOX) model of HER-2-positive cervical cancer expressing the clinical metastatic pattern.

    Get PDF
    Squamous cell carcinoma of the cervix, highly prevalent in the developing world, is often metastatic and treatment resistant with no standard treatment protocol. Our laboratory pioneered the patient-derived orthotopic xenograft (PDOX) nude mouse model with the technique of surgical orthotopic implantation (SOI). Unlike subcutaneous transplant patient-derived xenograft (PDX) models, PDOX models metastasize. Most importantly, the metastasis pattern correlates to the patient. In the present report, we describe the development of a PDOX model of HER-2-positive cervical cancer. Metastasis after SOI in nude mice included peritoneal dissemination, liver metastasis, lung metastasis as well as lymph node metastasis reflecting the metastatic pattern in the donor patient. Metastasis was detected in 4 of 6 nude mice with primary tumors. Primary tumors and metastases in the nude mice had histological structures similar to the original tumor and were stained by an anti-HER-2 antibody in the same pattern as the patient's cancer. The metastatic pattern, histology and HER-2 tumor expression of the patient were thus preserved in the PDOX model. In contrast, subcutaneous transplantation of the patient's cervical tumors resulted in primary growth but not metastasis

    Tumor-Targeting Salmonella typhimurium A1-R in Combination with Trastuzumab Eradicates HER-2-Positive Cervical Cancer Cells in Patient-Derived Mouse Models.

    Get PDF
    We have previously developed mouse models of HER-2-positive cervical cancer. Tumors in nude mice had histological structures similar to the original tumor and were stained by anti-HER-2 antibody in the same pattern as the patient's cancer. We have also previously developed tumor-targeting Salmonella typhimurium A1-R and have demonstrated its efficacy against patient-derived tumor mouse models, both alone and in combination. In the current study, we determined the efficacy of S. typhimurium A1-R in combination with trastuzumab on a patient-cancer nude-mouse model of HER-2 positive cervical cancer. Mice were randomized to 5 groups and treated as follows: (1) no treatment; (2) carboplatinum (30 mg/kg, ip, weekly, 5 weeks); (3) trastuzumab (20 mg/kg, ip, weekly, 5 weeks); (4) S. typhimurium A1-R (5 × 107 CFU/body, ip, weekly, 5 weeks); (5) S. typhimurium A1-R (5 × 107 CFU/body, ip, weekly, 5 weeks) + trastuzumab (20 mg/kg, ip, weekly, 5 weeks). All regimens had significant efficacy compared to the untreated mice. The relative tumor volume of S. typhimurium A1-R + trastuzumab-treated mice was smaller compared to trastuzumab alone (p = 0.007) and S. typhimurium A1-R alone (p = 0.039). No significant body weight loss was found compared to the no treatment group except for carboplatinum-treated mice (p = 0.021). Upon histological examination, viable tumor cells were not detected, and replaced by stromal cells in the tumors treated with S. typhimurium A1-R + trastuzumab. The results of the present study suggest that S. typhimurium A1-R and trastuzumab in combination are highly effective against HER-2-expressing cervical cancer

    Temporal resolution measurement of 128-slice dual source and 320-row area detector computed tomography scanners in helical acquisition mode using the impulse method

    Get PDF
    Purpose: To analyse the temporal resolution (TR) of modern computed tomography (CT) scanners using the impulse method, and assess the actual maximum TR at respective helical acquisition modes. Methods: To assess the actual TR of helical acquisition modes of a 128-slice dual source CT (DSCT) scanner and a 320-row area detector CT (ADCT) scanner, we assessed the TRs of various acquisition combinations of a pitch factor (P) and gantry rotation time (R). Results: The TR of the helical acquisition modes for the 128-slice DSCT scanner continuously improved with a shorter gantry rotation time and greater pitch factor. However, for the 320-row ADCT scanner, the TR with a pitch factor of 1.0, it was approximately one half of the gantry rotation time. The maximum TR values of single- and dual-source helical acquisition modes for the 128-slice DSCT scanner were 0.138 (R/. P = 0.285/1.5) and 0.074. s (R/. P = 0.285/3.2), and the maximum TR values of the 64. ×. 0.5- and 160. ×. 0.5-mm detector configurations of the helical acquisition modes for the 320-row ADCT scanner were 0.120 (R/. P = 0.275/1.375) and 0.195. s (R/. P = 0.3/0.6), respectively. Conclusion: Because the TR of a CT scanner is not accurately depicted in the specifications of the individual scanner, appropriate acquisition conditions should be determined based on the actual TR measurement. © 2016 Associazione Italiana di Fisica Medica
    corecore