2,417 research outputs found

    Etiology of otosclerosis

    Get PDF

    Local Phonon Density of States in an Elastic Substrate

    Full text link
    The local, eigenfunction-weighted acoustic phonon density of states (DOS) tensor is calculated for a model substrate consisting of a semi-infinite isotropic elastic continuum with a stress-free surface. On the surface, the local DOS is proportional to the square of the frequency, as for the three-dimensional Debye model, but with a constant of proportionality that is considerably enhanced compared to the Debye value, a consequence of the Rayleigh surface modes. The local DOS tensor at the surface is also anisotropic, as expected. Inside the substrate the local DOS is both spatially anisotropic and non-quadratic in frequency. However, at large depths, the local DOS approaches the isotropic Debye value. The results are applied to a Si substrate.Comment: 7 pages, 2 figures, RevTe

    Magnetic and electric properties of double-perovskites and estimation of their Curie temperatures by ab initio calculations

    Full text link
    First principles electronic structure calculations have been carried out on ordered double perovskites Sr_2B'B"O_6 (for B' = Cr or Fe and B" 4d and 5d transition metal elements) with increasing number of valence electrons at the B-sites, and on Ba_2MnReO_6 as well as Ba_2FeMoO_6. The Curie temperatures are estimated ab initio from the electronic structures obtained with the local spin-density functional approximation, full-potential generalized gradient approximation and/or the LDA+U method (U - Hubbard parameter). Frozen spin-spirals are used to model the excited states needed to evaluate the spherical approximation for the Curie temperatures. In cases, where the induced moments on the oxygen was found to be large, the determination of the Curie temperature is improved by additional exchange functions between the oxygen atoms and between oxygen and B' and B" atoms. A pronounced systematics can be found among the experimental and/or calculated Curie temperatures and the total valence electrons of the transition metal elements.Comment: 8 pages, 11 figures. Submitted to the Physical Review

    Early transitions and tertiary enrolment: The cumulative impact of primary and secondary effects on entering university in Germany

    Full text link
    Our aim is to assess how the number of working class students entering German universities can effectively be increased. Therefore, we estimate the proportion of students from the working class that would successfully enter university if certain policy interventions were in place to eliminate primary effects (performance differentials between social classes) and/or secondary effects (choice differentials net of performance) at different transition points. We extend previous research by analysing the sequence of transitions between elementary school enrolment and university enrolment and by accounting for the impact that manipulations at earlier transitions have on the performance distribution and size of the student ‘risk-set’ at subsequent transitions. To this end, we develop a novel simulation procedure which also seeks to find viable solutions to the shortcomings in the German data landscape. Our findings show that interventions are most effective if they take place early in the educational career. Neutralizing secondary effects at the transition to upper secondary school proves to be the single most effective means to increase participation rates in tertiary education among working class students. However, this comes at the expense of lower average performance levels. (DIPF/author

    Wideband digital phase comparator for high current shunts

    Full text link
    A wideband phase comparator for precise measurements of phase difference of high current shunts has been developed at INRIM. The two-input digital phase detector is realized with a precision wideband digitizer connected through a pair of symmetric active guarded transformers to the outputs of the shunts under comparison. Data are first acquired asynchronously, and then transferred from on-board memory to host memory. Because of the large amount of data collected the filtering process and the analysis algorithms are performed outside the acquisition routine. Most of the systematic errors can be compensated by a proper inversion procedure. The system is suitable for comparing shunts in a wide range of currents, from several hundred of milliampere up to 100 A, and frequencies ranging between 500 Hz and 100 kHz. Expanded uncertainty (k=2) less than 0.05 mrad, for frequency up to 100 kHz, is obtained in the measurement of the phase difference of a group of 10 A shunts, provided by some European NMIs, using a digitizer with sampling frequency up to 1 MHz. An enhanced version of the phase comparator employs a new digital phase detector with higher sampling frequency and vertical resolution. This permits to decrease the contribution to the uncertainty budget of the phase detector of a factor two from 20 kHz to 100 kHz. Theories and experiments show that the phase difference between two high precision wideband digitizers, coupled as phase detector, depends on multiple factors derived from both analog and digital imprint of each sampling system.Comment: 20 pages, 9 figure

    First Energy and Angle differential Measurements of e^+e^- -pairs emitted by Internal Pair Conversion of excited Heavy Nuclei

    Get PDF
    We present the first energy and angle resolved measurements of e+e- pairs emitted from heavy nuclei (Z>=40) at rest by internal pair conversion (IPC) of transitions with energies of less than 2MeV as well as recent theoretical results using the DWBA method, which takes full account of relativistic effects, magnetic substates and finite size of the nucleus. The 1.76MeV E0 transition in Zr90 (Sr source) and the 1.77MeV M1 transition in Pb207 (Bi source) have been investigated experimentally using the essentially improved set-up at the double-ORANGE beta-spectrometer of GSI. The measurements prove the capability of the setup to cleanly identify the IPC pairs in the presence of five orders of magnitude higher beta- and gamma background from the same source and to yield essentially background-free sum spectra despite the large background. Using the ability of the ORANGE setup to directly determine the opening angle of the e+e- pairs, the angular correlation of the emitted pairs was measured. In the Zr90 case the correlation could be deduced for a wide range of energy differences of the pairs. The Zr90 results are in good agreement with recent theory. The angular correlation deduced for the M1 transition in Pb207 is in strong disagreement with theoretical predictions derived within the Born approximation and shows almost isotropic character. This is again in agreement with the new theoretical results.Comment: LaTeX, 28 pages incl. 10 PS figures; Accepted by Z.Phys.

    Positron spectra from internal pair conversion observed in {238}U + {181}Ta collisions

    Get PDF
    We present new results from measurements and simulations of positron spectra, originating from 238U + 181Ta collisions at beam energies close to the Coulomb barrier. The measurements were performed using an improved experimental setup at the double-Orange spectrometer of GSI. Particular emphasis is put on the signature of positrons from Internal-Pair-Conversion (IPC) processes in the measured e+ energy spectra, following the de-excitation of electromagnetic transitions in the moving Ta-like nucleus. It is shown by Monte Carlo simulations that, for the chosen current sweeping procedure used in the present experiments, positron emission from discrete IPC transitions can lead to rather narrow line structures in the measured energy spectra. The measured positron spectra do not show evidence for line structures within the statistical accuracy achieved, although expected from the intensities of the observed γ\gamma transitions (Eγ 1250−1600_{\gamma}~1250-1600 keV) and theoretical conversion coefficients. This is due to the reduced detection efficiency for IPC positrons, caused by the limited spatial and momentum acceptance of the spectrometer. A comparison with previous results, in which lines have been observed, is presented and the implications are discussed.Comment: LaTeX, 20 pages including 5 EPS figures; Accepted by Eur. Phys.Jour.
    • …
    corecore