1,057 research outputs found

    Influence of the waist diameters on transmission characteristics and strain sensitivity of microtapered long-period fiber gratings

    Get PDF
    Transmission characteristics of microtapered long-period fiber gratings (MTLPGs) and their strain and temperature sensitivities with variations in the waist diameters are investigated theoretically and experimentally. Transmission characteristics of MTLPGs strongly depend on the waist diameter of the tapered optical fiber (TOF) because of the modification of the effective index difference between the core and the cladding modes. Based on the photoelastic effect, the resonant wavelengths of MTLPGs with variations in strain shift to shorter wavelengths. The strain sensitivity of the MTLPG with a waist diameter of 25 μm is improved by a factor of 20 compared with that of a 125 μm long-period fiber grating. The temperature sensitivities of MTLPGs are also enhanced by reducing the waist diameter of the TOF

    CSGM Designer: a platform for designing cross-species intron-spanning genic markers linked with genome information of legumes.

    Get PDF
    BackgroundGenetic markers are tools that can facilitate molecular breeding, even in species lacking genomic resources. An important class of genetic markers is those based on orthologous genes, because they can guide hypotheses about conserved gene function, a situation that is well documented for a number of agronomic traits. For under-studied species a key bottleneck in gene-based marker development is the need to develop molecular tools (e.g., oligonucleotide primers) that reliably access genes with orthology to the genomes of well-characterized reference species.ResultsHere we report an efficient platform for the design of cross-species gene-derived markers in legumes. The automated platform, named CSGM Designer (URL: http://tgil.donga.ac.kr/CSGMdesigner), facilitates rapid and systematic design of cross-species genic markers. The underlying database is composed of genome data from five legume species whose genomes are substantially characterized. Use of CSGM is enhanced by graphical displays of query results, which we describe as "circular viewer" and "search-within-results" functions. CSGM provides a virtual PCR representation (eHT-PCR) that predicts the specificity of each primer pair simultaneously in multiple genomes. CSGM Designer output was experimentally validated for the amplification of orthologous genes using 16 genotypes representing 12 crop and model legume species, distributed among the galegoid and phaseoloid clades. Successful cross-species amplification was obtained for 85.3% of PCR primer combinations.ConclusionCSGM Designer spans the divide between well-characterized crop and model legume species and their less well-characterized relatives. The outcome is PCR primers that target highly conserved genes for polymorphism discovery, enabling functional inferences and ultimately facilitating trait-associated molecular breeding

    Human dopamine receptor nanovesicles for gate-potential modulators in high-performance field-effect transistor biosensors

    Get PDF
    The development of molecular detection that allows rapid responses with high sensitivity and selectivity remains challenging. Herein, we demonstrate the strategy of novel bio-nanotechnology to successfully fabricate high-performance dopamine (DA) biosensor using DA Receptor-containing uniform-particle-shaped Nanovesicles-immobilized Carboxylated poly(3,4-ethylenedioxythiophene) (CPEDOT) NTs (DRNCNs). DA molecules are commonly associated with serious diseases, such as Parkinson's and Alzheimer's diseases. For the first time, nanovesicles containing a human DA receptor D1 (hDRD1) were successfully constructed from HEK-293 cells, stably expressing hDRD1. The nanovesicles containing hDRD1 as gate-potential modulator on the conducting polymer (CP) nanomaterial transistors provided high-performance responses to DA molecule owing to their uniform, monodispersive morphologies and outstanding discrimination ability. Specifically, the DRNCNs were integrated into a liquid-ion gated field-effect transistor (FET) system via immobilization and attachment processes, leading to high sensitivity and excellent selectivity toward DA in liquid state. Unprecedentedly, the minimum detectable level (MDL) from the field-induced DA responses was as low as 10 pM in real- time, which is 10 times more sensitive than that of previously reported CP based-DA biosensors. Moreover, the FET-type DRNCN biosensor had a rapid response time (<1 s) and showed excellent selectivity in human serum

    Successful management of heterotopic cornual pregnancy with laparoscopic cornual resection

    Get PDF
    AbstractObjectiveTo examine the feasibility of laparoscopic cornual resection for the treatment of heterotopic cornual pregnancy.Study designWomen who underwent laparoscopic cornual resection for heterotopic cornual pregnancy at our hospital between January 2003 and March 2015 were retrospectively analyzed. We evaluated significant parameters such as operative complications and postoperative pregnancy outcomes of concomitant pregnancy.ResultsThirteen patients with heterotopic cornual pregnancy were included in the study. All were pregnant through assisted reproductive technology, and the diagnosis was made at a median of 6+6 weeks (range 5+4–10+0). They were successfully treated with laparoscopic cornual resection and admitted for a median of 4 days (range, 2–7) postoperatively. The median operative time was 65min (range, 35–145min) and estimated blood loss was 200mL (range, 10–3000mL). There was a spontaneous abortion at 7+6 gestational weeks in a patient who received bilateral cornual resection. Seven patients delivered babies at term and 3 at preterm. All 10 women delivered without any maternal or neonatal complications. Two were lost to follow-up.ConclusionsLaparoscopic cornual resection is a feasible primary approach for the management of heterotopic cornual pregnancy

    Acute Symptoms after a Community Hydrogen Fluoride Spill

    Get PDF
    OBJECTIVES: This study was conducted to describe the demographic characteristics, and clinical signs and symptoms of patients who visited a general hospital because of the release of chemically hazardous hydrogen fluoride that occurred on September 27, 2012 in Gumi City, Korea. METHODS: The medical records at 1 general hospital 9 km from the accident site were reviewed using a standardized survey format. There were 1,890 non-hospitalized and 12 hospitalized patients exposed to hydrogen fluoride between September 27 and October 13 2012. RESULTS: Among the 12 hospitalized patients, 11 were discharged within 1 week and the other was hospitalized for 10 days. The chief complaints were respiratory symptoms such as hemoptysis and shortness of breath, gastrointestinal symptoms, neurologic symptoms, sore throat, and lip burn. The number of non-hospitalized patients exhibited a bimodal distribution, peaking on the first and twelfth days after the accident. Their chief complaints were sore throat (24.1%), headache (19.1%), cough (13.1%), and eye irritation (9.2%); some patients were asymptomatic (6.2%). Patients who visited the hospital within 3 days (early patients) of the spill more often had shortness of breath (27.0%) and nausea (6.3%) as the chief complaints than patients who visited after 3 days (late patients) (3.5% and 2.6%, respectively). However, cough and rhinorrhea were more common in the late patients (14.0% and 3.3%, respectively) than in the early patients (5.0% and 0.0%, respectively). Patients who were closer to the accident site more often had shortness of breath and sputum as the chief complaints than patients who were farther away. The mean serum calcium concentration was 9.37 mg/dL (range: 8.4–11.0 mg/dL); none of the patients had a decreased serum calcium level. Among 48 pulmonary function test results, 4 showed decreased lung function. None of the patients had abnormal urine fluoride levels on the eighth day after exposure. CONCLUSIONS: Patients hospitalized due to chemical hazard release of hydrogen fluoride had acute respiratory, gastrointestinal, and neurologic health problems. Non-hospitalized patients have acute symptoms mainly related to upper respiratory irritation

    Occupational Factors Associated with Changes in the Body Mass Index of Korean Male Manual Workers

    Get PDF
    OBJECTIVES: This study was carried out to analyze and compare the occupational factors that could influence changes in body mass index (BMI) in male manual workers stratified into short-term and long-term work experience groups. METHODS: The subjects were 299 male manual workers (sampled systematically) from 27 workplaces, who had undergone travelling medical examinations at a university hospital between March 28 and May 10, 2013, and had also undergone medical examinations at the same hospital in 2012. Their general and occupational characteristics were investigated through a structured, self-administered questionnaire. The BMI at each point in time was calculated based on the anthropometric results of the medical examinations. Multiple regression analyses were conducted on outcomes of the BMI change and predictors composed of the general and occupational characteristics, with the subjects stratified into groups with 5 years or less (short-term) versus more than 5 years (long-term) of work experience at the present post. RESULTS: In the short-term work experience group, the BMI increases of 3-shift workers and groups reporting disagreement with feeling “insufficient job control” and “lack of reward” at work, two of the subscales of job stress, were significantly higher than those of daytime workers and high-stress groups, respectively. In the long-term work experience group, However, although the BMI increase for 3-shift workers was also significantly higher than that of daytime workers, none of the job stress factors were significantly associated with a BMI increase, whereas the social factors of education and marital status were significant, and some lifestyle factors (such as smoking and regular exercise) were also significant. CONCLUSION: This study showed that, except for 3-shift work, the factors associated with BMI increase could differ depending on the length of job experience. Consequently, different strategies may be needed for workers with short-term versus long-term job experience when designing interventions for preventing their obesity

    Interrupted aortic arch diagnosed with loss of femoral pulse in a patient undergoing patent ductus arteriosus ligation -A case report-

    Get PDF
    A 12-year-old boy with ventricular septal defect and patent ductus arteriosus was presented to the operating room. Upon clamping the patent ductus arteriosus, the femoral arterial pressure curve was lost; however, it returned upon unclamping. Upon further dissection, an interrupted aortic arch was found between the left subclavian artery and patent ductus arteriosus. The surgery was discontinued for further evaluation

    Successful removal of kinked J-guide wire under fluoroscopic guidance during central venous catheterization -A case report-

    Get PDF
    Guidewire-associated complications that occur during the process of central venous catheterization include its kinking, looping, knotting and breakage. The removal of a looped or knotted guidewire is problematic because it can cause vessel damage, major hemorrhage, or embolization of a fractured guidewire. We report a case of guidewire kinking and its successful removal under fluoroscopic guidance
    corecore