41 research outputs found

    Neutrinoless double beta decay in the economical 3-3-1 model

    Get PDF
    Possible contributions to neutrinoless double beta (ββ)0ν decay in the economical 3-3-1 model are discussed. We show that the (ββ)0ν decay in this model is due to both sources—Majorana L and Dirac D neutrino masses. If the mixing angle between charged gauge bosons, the standard model W and bilepton Y , is in range of the ratio of neutrino masses L/D, both the Majorana and Dirac masses simultaneously give contributions dominant to the decay. As results, constraints on the bilepton mass are also given

    Medication Adherence in Cardiovascular Diseases

    Get PDF
    Cardiovascular disease is a significant cause of death globally. While effective long-term medications that reduce the risk of morbidity and mortality related to cardiovascular disease are readily available, nonadherence to prescribed medications remains a significant reason for suboptimal management. Consequently, this might lead to increased morbidity and mortality and healthcare costs. Medication nonadherence causes are myriad and complicated, with factors at the patient, healthcare provider, and health system levels. Many clinical trials have investigated interventions to target these factors for improving medication adherence, including improving patient education, testing behavioral interventions, implementing medication reminder tools, reducing medication costs, utilizing social support, utilizing healthcare team members, and simplifying medication dosing regimens. This book chapter describes factors influencing medication adherence and highlights the impact of varying levels of adherence on patients’ clinical and economic outcomes. We also summarize interventions for improving medication adherence in cardiovascular disease

    The Virome of Acute Respiratory Diseases in Individuals at Risk of Zoonotic Infections

    Get PDF
    The ongoing coronavirus disease 2019 (COVID-19) pandemic emphasizes the need to actively study the virome of unexplained respiratory diseases. We performed viral metagenomic next-generation sequencing (mNGS) analysis of 91 nasal-throat swabs from individuals working with animals and with acute respiratory diseases. Fifteen virus RT-PCR-positive samples were included as controls, while the other 76 samples were RT-PCR negative for a wide panel of respiratory pathogens. Eukaryotic viruses detected by mNGS were then screened by PCR (using primers based on mNGS-derived contigs) in all samples to compare viral detection by mNGS versus PCR and assess the utility of mNGS in routine diagnostics. mNGS identified expected human rhinoviruses, enteroviruses, influenza A virus, coronavirus OC43, and respiratory syncytial virus (RSV) A in 13 of 15 (86.7%) positive control samples. Additionally, rotavirus, torque teno virus, human papillomavirus, human betaherpesvirus 7, cyclovirus, vientovirus, gemycircularvirus, and statovirus were identified through mNGS. Notably, complete genomes of novel cyclovirus, gemycircularvirus, and statovirus were genetically characterized. Using PCR screening, the novel cyclovirus was additionally detected in 5 and the novel gemycircularvirus in 12 of the remaining samples included for mNGS analysis. Our studies therefore provide pioneering data of the virome of acute-respiratory diseases from individuals at risk of zoonotic infections. The mNGS protocol/pipeline applied here is sensitive for the detection of a variety of viruses, including novel ones. More frequent detections of the novel viruses by PCR than by mNGS on the same samples suggests that PCR remains the most sensitive diagnostic test for viruses whose genomes are known. The detection of novel viruses expands our understanding of the respiratory virome of animal-exposed humans and warrant further studies.Peer reviewe

    Viral Metagenomic Analysis of Cerebrospinal Fluid from Patients with Acute Central Nervous System Infections of Unknown Origin, Vietnam.

    Get PDF
    Central nervous system (CNS) infection is a serious neurologic condition, although the etiology remains unknown in >50% of patients. We used metagenomic next-generation sequencing to detect viruses in 204 cerebrospinal fluid (CSF) samples from patients with acute CNS infection who were enrolled from Vietnam hospitals during 2012-2016. We detected 8 viral species in 107/204 (52.4%) of CSF samples. After virus-specific PCR confirmation, the detection rate was lowered to 30/204 (14.7%). Enteroviruses were the most common viruses detected (n = 23), followed by hepatitis B virus (3), HIV (2), molluscum contagiosum virus (1), and gemycircularvirus (1). Analysis of enterovirus sequences revealed the predominance of echovirus 30 (9). Phylogenetically, the echovirus 30 strains belonged to genogroup V and VIIb. Our results expanded knowledge about the clinical burden of enterovirus in Vietnam and underscore the challenges of identifying a plausible viral pathogen in CSF of patients with CNS infections

    Evaluation of the Luminex xTAG Respiratory Viral Panel FAST v2 assay for detection of multiple respiratory viral pathogens in nasal and throat swabs in Vietnam.

    Get PDF
    BACKGROUND: Acute respiratory infections (ARI) are among the leading causes of hospitalization in children ≤5 years old. Rapid diagnostics of viral pathogens is essential to avoid unnecessary antibiotic treatment, thereby slowing down antibiotic-resistance. We evaluated the diagnostic performance of the Luminex xTAG Respiratory Viral Panel FAST v2 against viral specific PCR as reference assays for ARI in Vietnam. METHODS: Four hundred and forty two nose and throat swabs were collected in viral transport medium, and were tested with Luminex xTAG Respiratory Viral Panel FAST v2. Multiplex RT-PCR and single RT-PCR were used as references.    Results: Overall, viral pathogens were detected in a total count of 270/294 (91.8%, 95% CI 88.1-94.7) by the Luminex among reference assays, whilst 112/6336 (1.8%, 95% CI, 1.4-2.1) of pathogens were detected by the Luminex, but not by reference assays. Frequency of pathogens detected by Luminex and reference assays was 379 and 292, respectively. The diagnostic yield was 66.7% (295/442, 95%CI 62.1-71.1%) for the Luminex assay and 54.1% (239/442, 95% CI, 49.3-58.8%) for reference assays. The Luminex kit had higher yields for all viruses except influenza B virus, respiratory syncytial virus, and human bocavirus. High agreements between both methods [mean (range): 0.91 (0.83-1.00)] were found for 10/15 viral agents. CONCLUSIONS: The Luminex assay is a high throughput multiplex platform for rapid detection of common viral pathogens causing ARI. Although the current high cost may prevent Luminex assays from being widely used, especially in limited resource settings where ARI are felt most, its introduction in clinical diagnostics may help reduce unnecessary use of antibiotic prescription

    Insulin signaling and its application

    Get PDF
    The discovery of insulin in 1921 introduced a new branch of research into insulin activity and insulin resistance. Many discoveries in this field have been applied to diagnosing and treating diseases related to insulin resistance. In this mini-review, the authors attempt to synthesize the updated discoveries to unravel the related mechanisms and inform the development of novel applications. Firstly, we depict the insulin signaling pathway to explain the physiology of insulin action starting at the receptor sites of insulin and downstream the signaling of the insulin signaling pathway. Based on this, the next part will analyze the mechanisms of insulin resistance with two major provenances: the defects caused by receptors and the defects due to extra-receptor causes, but in this study, we focus on post-receptor causes. Finally, we discuss the recent applications including the diseases related to insulin resistance (obesity, cardiovascular disease, Alzheimer’s disease, and cancer) and the potential treatment of those based on insulin resistance mechanisms

    Evaluation of Luminex xTAG Gastrointestinal Pathogen Panel Assay for Detection of Multiple Diarrheal Pathogens in Fecal Samples in Vietnam.

    Get PDF
    Diarrheal disease is a complex syndrome that remains a leading cause of global childhood morbidity and mortality. The diagnosis of enteric pathogens in a timely and precise manner is important for making treatment decisions and informing public health policy, but accurate diagnosis is a major challenge in industrializing countries. Multiplex molecular diagnostic techniques may represent a significant improvement over classical approaches. We evaluated the Luminex xTAG gastrointestinal pathogen panel (GPP) assay for the detection of common enteric bacterial and viral pathogens in Vietnam. Microbiological culture and real-time PCR were used as gold standards. The tests were performed on 479 stool samples collected from people admitted to the hospital for diarrheal disease throughout Vietnam. Sensitivity and specificity were calculated for the xTAG GPP for the seven principal diarrheal etiologies. The sensitivity and specificity for the xTAG GPP were >88% for Shigellaspp.,Campylobacterspp., rotavirus, norovirus genotype 1/2 (GI/GII), and adenovirus compared to those of microbiological culture and/or real-time PCR. However, the specificity was low (∼60%) for Salmonella species. Additionally, a number of important pathogens that are not identified in routine hospital procedures in this setting, such as Cryptosporidiumspp. and Clostridium difficile, were detected with the GPP. The use of the Luminex xTAG GPP for the detection of enteric pathogens in settings, like Vietnam, would dramatically improve the diagnostic accuracy and capacity of hospital laboratories, allowing for timely and appropriate therapy decisions and a wider understanding of the epidemiology of pathogens associated with severe diarrheal disease in low-resource settings

    GRADIENT KIẾN TẠO HIỆN ĐẠI KHU VỰC NINH THUẬN VÀ LÂN CẬN

    Get PDF
    The estimation of the present day tectonic movement and tectonic gradient (strain rate) has an important practical signification in the assessment of active fault and seismic hazards for the selection of Ninh Thuan nuclear power plant. Based on the three campaigns of GPS measurement between 2012 - 2013, we used BERNESE 5.0 software to determine present day slip rates of 13 stations in ITRF08 frame. The GPS stations move eastwards at the slip rates of 22 - 25 mm/yr, southwards at the velocities of 5 - 10 mm/yr. The standard errors in latitudinal and longitudinal directions are 1.2 mm/yr and 0.9 mm/yr, respectively. Combined with GPS data from the project of the study on actual geodynamics in Tay Nguyen TN3/06, we determined the strain rate ranging from 50 to 100 nanostrains with the standard error of 50 nanostrains. The direction of  maximum compressive strain rate is from northwest - southeast to east - west.Đánh giá vận tốc chuyển động kiến tạo hiện đại và gradient kiến tạo hiện đại có ý nghĩa thực tiễn quan trọng trong việc đánh giá đứt gãy hoạt động nguy hiểm động đất phục vụ xây dụng nhà máy điện hạt nhân Ninh Thuận. Trên cơ sở đo 3 chu kỳ GPS vào các năm 2012 - 2013, sử dụng phần mềm BERNESE 5.0, chúng tôi đã xác lập được vận tốc chuyển động kiến tạo hiện đại tại 13 điểm đo GPS trong khu vực lân cận bao gồm kéo dài từ Nha Trang tới đảo Phú Quý. Vận tốc chuyển dịch kiến tạo hiện đại về phía đông thay đổi từ 22 - 25 mm/năm và chuyển dịch về phía nam với vận tốc giao động từ 5 - 10 mm/năm trên hệ tọa độ toàn cầu ITRF08. Sai số vận tốc chuyển dịch kiến tạo về phía đông giao động trong khoảng 1,2 - 1,5 mm/năm và về phía nam giao động trong khoảng 0,9 - 1,2 mm/năm. Liên kết với giá trị đo GPS từ đề tài nghiên cứu địa động lực hiện đại khu vực Tây Nguyên mã số TN3/T06, chúng tôi đã xác định được giá trị vận tốc biến dạng giao động từ 50 nano tới 100 nano biến dạng với sai số giao động trong khoảng 50 nano biến dạng. Trục biến dạng nén cực đại giao động theo phương thay đổi từ bắc nam sang đông bắc - tây nam. Trục biến dạng căng cực đại có phương thay đổi từ tây bắc - đông nam sang phương đông - tây

    PRESENT DAY DEFORMATION IN THE EAST VIETNAM SEA AND SURROUNDING REGIONS

    Get PDF
    This paper presents velocities of present-day tectonic movement and strain rate in the East Vietnam Sea (South China Sea) and surroundings determined from GPS campaigns between 2007 and 2010. We determine absolute velocities of GPS stations in the ITRF05 frame. The result indicates that GPS stations in the North of East Vietnam Sea move eastwards with the slip rate of 30 - 39 mm/yr, southwards at the velocities of 8 - 11 mm/yr. Song Tu Tay offshore moves eastwards at the rate of ~24 mm/yr and southwards at ~9 mm/yr. GPS stations in the South of East Vietnam Sea move to the east at the rate of ~22 mm/yr and to the south at the velocities of 7 - 11 mm/yr. The effect of relative movement shows that the Western Margin Fault Zone activates as left lateral fault zone at the slip rate less than 4 mm/year.In Western plateau, the first result from 2012 - 2013 GPS measurement shows that the velocities to the east vary from 21.5 mm/yr to 24.7 mm/year. The velocities to the south vary from 10.5 mm/yr to 14.6 mm/year. GPS solutions determined from our campaigns are combined with data from various authors and international projects to determine the strain rate in the East Vietnam Sea. Principal strain rate changes from 15 nanostrain/yr to 9 nanostrain/yr in the East Vietnam Sea. Principal strain rate and maximum shear strain rate along the Red River Fault Zone are in order of 10 nanostrain/year. East Vietnam Sea is considered to belong to the Sunda block
    corecore