4,801 research outputs found

    Recognition-Controlled Membrane Translocation for Signal Transduction across Lipid Bilayers

    Get PDF
    Membrane signaling proteins transduce information across lipid bilayer membranes in response to extra-cellular binding of chemical messengers. The design of chemical systems that initiate transmembrane signal transduction through molecular binding events is a critical step toward preparing responsive synthetic vesicles. Here we report a vesicle-based signaling system controlled by a metal cation binding event. Competition between binding of copper ions to a membrane-embedded synthetic transducer and to an extra-vesicle messenger (EDTA) is used to control translocation of the transducer across the lipid bilayer. The translocation process is coupled to activation of a catalyst that turns over encapsulated substrates on the inside of the vesicle to generate an amplified fluorescence output signal. External EDTA and copper ions can be used to reversibly switch catalysis inside the vesicles on and off in a controlled manner

    Wide variation in susceptibility of transmitted/founder HIV-1 subtype C Isolates to protease inhibitors and association with in vitro replication efficiency

    Get PDF
    © 2016 The Author(s).The gag gene is highly polymorphic across HIV-1 subtypes and contributes to susceptibility to protease inhibitors (PI), a critical class of antiretrovirals that will be used in up to 2 million individuals as second-line therapy in sub Saharan Africa by 2020. Given subtype C represents around half of all HIV-1 infections globally, we examined PI susceptibility in subtype C viruses from treatment-naïve individuals. PI susceptibility was measured in a single round infection assay of full-length, replication competent MJ4/gag chimeric viruses, encoding the gag gene and 142 nucleotides of pro derived from viruses in 20 patients in the Zambia-Emory HIV Research Project acute infection cohort. Ten-fold variation in susceptibility to PIs atazanavir and lopinavir was observed across 20 viruses, with EC50 s ranging 0.71-6.95 nM for atazanvir and 0.64-8.54 nM for lopinavir. Ten amino acid residues in Gag correlated with lopinavir EC50 (p < 0.01), of which 380 K and 389I showed modest impacts on in vitro drug susceptibility. Finally a significant relationship between drug susceptibility and replication capacity was observed for atazanavir and lopinavir but not darunavir. Our findings demonstrate large variation in susceptibility of PI-naïve subtype C viruses that appears to correlate with replication efficiency and could impact clinical outcomes

    Dermal reaction and bigeminal premature ventricular contractions due to neostigmine: a case report

    Get PDF
    <p>Abstract</p> <p>Introduction</p> <p>Neostigmine is a frequently used acetylcholinesterase inhibitor administered to reverse muscular relaxation caused by nondepolarizing neuromuscular relaxants in patients recovering from general anesthesia. Severe allergic reactions and urticaria are rarely reported following the use of neostigmine bromide, and never with methylsulfate-containing drugs. In this case, bigeminal premature ventricular contractions added to urticaria provides a warning about the possibility of a life-threatening situation.</p> <p>Case presentation</p> <p>We report the case of a 23-year-old Persian woman who presented with bigeminal premature ventricular contractions along with urticarial lesions on her arm and trunk as soon as she was administered neostigmine methylsulfate after undergoing a laparoscopy for ectopic pregnancy.</p> <p>Conclusion</p> <p>This case report could be of value not only for anesthesiologists who routinely use neostigmine but also for others who administer the pharmaceutical preparation in other situations. The report presents a rare case of drug reaction following neostigmine use. As a result, one should consider any drug a probable cause of drug reaction. The preparation of resuscitative facilities, therefore, is necessary prior to the prescription of the medication.</p

    Triggered release from lipid bilayer vesicles by an artificial transmembrane signal transduction system

    Get PDF
    The on-demand delivery of drug molecules from nano-scale carriers with spatio-temporal control is a key challenge in modern medicine. Here we show that lipid bilayer vesicles (liposomes) can be triggered to release an encapsulated molecular cargo in response to an external control signal by employing an artificial transmembrane signal transduction mechanism. A synthetic signal transducer embedded in the lipid bilayer membrane acts as a switchable catalyst, catalyzing the formation of surfactant molecules inside the vesicle in response to a change in external pH. The surfactant permeabilises the lipid bilayer membrane to facilitate release of an encapsulated hydrophilic cargo. In the absence of the pH control signal, the catalyst is inactive and the cargo remains encapsulated within the vesicle.Oppenheimer Research Fund for an Early Career Research Fellowshi

    Local Ugandan Production of Stable 0.2% Chlorhexidine Eye Drops

    Get PDF
    Purpose: The purpose of this study was to develop a protocol to prepare buffered chlorhexidine (CHX) eye drops (0.2% w/v) in the United Kingdom that can be reproduced at a production facility in Uganda. Buffered CHX eye drops can prevent CHX degradation and improve ocular tolerability during the treatment of fungal keratitis. Methods: Buffered CHX eye drops in amber glass containers were prepared using sodium acetate buffer at pH 5.90 to 6.75. Two commercial CHX solutions and CHX in water were used as controls. Eye drops were stored at 40°C (70% humidity, 21 months) in the United Kingdom and at ambient temperature in Uganda (30 months). High-performance liquid chromatography was used to determine CHX stability over time, and pH was monitored. Sterility was achieved using an autoclave (121°C, 15 minutes) and water bath (100°C, 30 minutes). Results: The pH of acetate-buffered CHX eye drops did not change over 21 months a40°C or at ambient temperature (30 months), whereas the pH of the unbuffered aqueouCHX displayed significant fluctuations, with an increase in acidity. The CHX concentration remained the same in both buffered and unbuffered eye-drop solutions. Eye dropsterilization was successful using an autoclave and a water bath. Conclusions: Stable, sterile, buffered CHX eye drops (pH 6.75) were successfully prepared first in the United Kingdom and then reproducibly in Uganda. This eye drops can be prepared in a hospital or pharmacy setting with limited resources, thus providing a cost-effective treatment for fungal keratitis. Translational Relevance: A protocol has been developed to prepare buffered CHX eydrops in low-and middle-income countries to treat fungal keratitis

    Epicardial catheter ablation for ventricular tachycardia on uninterrupted warfarin: A safe approach for those with a strong indication for peri-procedural anticoagulation?

    Get PDF
    BACKGROUND: Current guidelines for epicardial catheter ablation for ventricular tachycardia (VT) advocate that epicardial access is avoided in anticoagulated patients and should be performed prior to heparinisation. Recent studies have shown that epicardial access may be safe in heparinised patients. However, no data exist for patients on oral anticoagulants. We investigated the safety of obtaining epicardial access on uninterrupted warfarin. METHODS: A prospective registry of patients undergoing epicardial VT ablation over two years was analysed. Consecutive patients in whom epicardial access was attempted were included. All patients were heparinised prior to epicardial access with a target activated clotting time (ACT) of 300-350s. Patients who had procedures performed on uninterrupted warfarin (in addition to heparin) were compared to those not taking an oral anticoagulant. RESULTS: 46 patients were included of which 13 were taking warfarin. There was no significant difference in clinical and procedural characteristics (except INR and AF) between the two groups. Epicardial access was achieved in all patients. There were no deaths and no patients required surgery. A higher proportion of patients in the warfarin group had a drop in haemoglobin of >2g/dL compared to the no-warfarin group (38.5% versus 27.3%, p=0.74) and delayed pericardial drain removal (7.8% versus 3.03%, p=0.47). There was no difference in overall procedural complication rate. No patients required warfarin reversal or blood transfusion. CONCLUSION: Epicardial access can be achieved safely and effectively in patients' anticoagulated with warfarin and heparinised with therapeutic ACT. This may be an attractive option for patients with a high stroke risk

    A propensity matched case-control study comparing efficacy, safety and costs of the subcutaneous vs. transvenous implantable cardioverter defibrillator.

    Get PDF
    BACKGROUND: Subcutaneous implantable cardioverter defibrillators (S-ICD) have become more widely available. However, comparisons with conventional transvenous ICDs (TV-ICD) are scarce. METHODS: We conducted a propensity matched case-control study including all patients that underwent S-ICD implantation over a five-year period in a single tertiary centre. Controls consisted of all TV-ICD implant patients over a contemporary time period excluding those with pacing indication, biventricular pacemakers and those with sustained monomorphic ventricular tachycardia requiring anti-tachycardia pacing. Data was collected on device-related complications and mortality rates. A cost efficacy analysis was performed. RESULTS: Sixty-nine S-ICD cases were propensity matched to 69 TV-ICD controls. During a mean follow-up of 31±19 (S-ICD) and 32±21months (TV-ICD; p=0.88) there was a higher rate of device-related complications in the TV-ICD group predominantly accounted for by lead failures (n=20, 29% vs. n=6, 9%; p=0.004). The total mean cost for each group, including the complication-related costs was £9967±4511 (13,639±6173)and£12,601±1786(13,639±6173) and £12,601±1786 (17,243±2444) in the TV-ICD and S-ICD groups respectively (p=0.0001). Even though more expensive S-ICD was associated with a relative risk reduction of device-related complication of 70% with a HR of 0.30 (95%CI 0.12-0.76; p=0.01) compared to TV-ICDs. CONCLUSIONS: TV-ICDs are associated with increased device-related complication rates compared to a propensity matched S-ICD group during a similar follow-up period. Despite the existing significant difference in unit cost of the S-ICD, overall S-ICD costs may be mitigated versus TV-ICDs over a longer follow-up period

    Early postnatal ozone exposure alters rat nodose and jugular sensory neuron development

    Get PDF
    Sensory neurons originating in nodose and jugular ganglia that innervate airway epithelium (airway neurons) play a role in inflammation observed following exposure to inhaled environmental irritants such as ozone (O3). Airway neurons can mediate airway inflammation through the release of the neuropeptide substance P (SP). While susceptibility to airway irritants is increased in early life, the developmental dynamics of afferent airway neurons are not well characterized. The hypothesis of this study was that airway neuron number might increase with increasing age, and that an acute, early postnatal O3 exposure might increase both the number of sensory airway neurons as well as the number SP-containing airway neurons. Studies using Fischer 344 rat pups were conducted to determine if age or acute O3 exposure might alter airway neuron number. Airway neurons in nodose and jugular ganglia were retrogradely labeled, removed, dissociated, and counted by means of a novel technique employing flow cytometry. In Study 1, neuron counts were conducted on postnatal days (PD) 6, 10, 15, 21, and 28. Numbers of total and airway neurons increased significantly between PD6 and PD10, then generally stabilized. In Study 2, animals were exposed to O3 (2 ppm) or filtered air (FA) on PD5 and neurons were counted on PD10, 15, 21, and 28. O3-exposed animals displayed significantly less total neurons on PD21 than FA controls. This study shows that age-related changes in neuron number occur, and that an acute, early postnatal O3 exposure significantly alters sensory neuron development
    corecore